= Montage editor [Under construction] = ''Authors: Francois Tadel'' <> The display of the time series figures can be configured using montages of sensors. The term ''montage ''in the Brainstorm interface can refer to a simple sub-selection of data channels, or a linear recombination of these channels (eg. average reference or other EEG re-referecing montage). The selection of channels was already introduced in the tutorials [[http://neuroimage.usc.edu/brainstorm/Tutorials/ReviewRaw#Montage_selection|Continuous recordings]] and [[http://neuroimage.usc.edu/brainstorm/Tutorials/Epilepsy#Multiple_montages|EEG and epilepsy]]. This page illustrates how to use the montage editor to create custom displays. == Pre-defined montages == The interface offers a few pre-defined montages for standard acquisition systems for MEG (Elekta-Neuromag, CTF, Yokogawa, 4D) and EEG (10-20 and 10-10 caps). The montage menu is accessible from the Record tab or with the popup menu on the time series figures. The keyboard shortcuts (Shift+A, Shift+B, etc), allow to jump quickly to a different montage. To display a second montage on the same recordings, open again the same file (right-click > Display time) and change the montage of the second window, as illustrated in the tutorial [[http://neuroimage.usc.edu/brainstorm/Tutorials/Epilepsy#Multiple_montages|EEG and epilepsy]]. {{attachment:menu_popup.gif}} == Montages == A better way to review a large number of MEG/EEG signals at once is to display only a subset of them at once. This can be done using the "montage" interface. The term refers mainly to EEG, to define the referencing system used to display the values recorded on the electrodes: bipolar montages, custom reference electrodes, average reference. However, the same interface can be used in MEG to select only a subset of sensors in a given figure, using a predefined or custom set of channels. * Use the drop-down menu in the Record tab to several predefined sets (ex. CTF LF = Group of left frontal sensors). Alternatively, right-click on the figure > Montage. You may need to decrease again the gain of the channels (use SHIFT+Mouse wheel) . {{http://neuroimage.usc.edu/brainstorm/Tutorials/TutExploreRecodings?action=AttachFile&do=get&target=selectionsMenu.gif|selectionsMenu.gif|class="attachment"}} * Note the keyboard shortcuts: '''SHIFT+letter'''. It makes it really easy to switch from a group of sensors to another (ex: Shift+A = all sensors, Shift+B = Left-frontal, Shift+C=Right-frontal...) * To edit/create your own selections, use the menu "Edit montages". You can edit the channels selection groups or the electrodes montages available for this installation of Brainstorm. By default, it shows only the ones that are relevant to the type of recordings you are currently looking at (in this case: CTF MEG recordings). To see all the available options, click on the button "All". * Click on "New channel selection" to create a new selection Test1, and select a few channels in the list. . {{http://neuroimage.usc.edu/brainstorm/Tutorials/TutExploreRecodings?action=AttachFile&do=get&target=selections.gif|selections.gif|class="attachment"}} * Click on Save. Back to the time series figure. Look in the popup menu again, you can see your new selection in the menu: Test1. You can now use the time series view with these predefined selections of sensors. * To display several montages at the same time, or with different different display options, you need to open twice the same file and then set the parameters differently. You have two option to clone the figure: * Do twice: Right-click on the file in the database explorer > MEG > Display time series * Right-click on a figure > Figure > Clone figure * To have the same scale in both figures, use the buttons "..." in the figures {{http://neuroimage.usc.edu/brainstorm/Tutorials/TutExploreRecodings?action=AttachFile&do=get&target=figClone.gif|figClone.gif|class="attachment"}} == Apply a montage to the recordings == The montage selection is only a visualization option, it never modifies the recordings. If you want to apply a specific montage to the recordings, you need to call the process '''Standardize > Re-reference EEG''' (see [[http://neuroimage.usc.edu/brainstorm/Tutorials/Epilepsy#Average_reference|EEG and Epilepsy]]) or the process '''Standardize > Apply montage''' (only available for imported epochs). <>