Tissue type |
Type of material |
LAC(cm-1) |
air |
Air |
1.04E-04 |
background |
Adipose tissue |
0.0913 |
skeleton |
bone cortical |
0.1717 |
eye |
Eye lens |
0.1012 |
medulla, olfactory bulbs, heart, lachrymal glands, bladder wall, stomach, spleen, pancreas, liver, kindeys, adrenal glands, skin |
Soft tissue |
0.1008 |
cerebellum, external cerebrum, striatum, rest of the brain |
Brain |
0.0994 |
testes |
Testis |
0.0993 |
masseter muscles |
Muscle |
0.0999 |
lungs |
Lung tissue |
0.0999 |
bladder content |
Water |
0.0960 |
tumors |
Soft tissue |
0.1008 |
Figure: Linear Attenuation Coefficients that are assigned to the tissues in the atlas image to create an attenuation coefficient image for PET simulation
For optical simulations scattering and absorption coefficients are computed using the optical properties reported in