= FEM median nerve tutorial =
<)>>
== Dataset description ==
==== Experiment ====
The experiment consists of an unilateral median nerve stimulation conducted in a MEG laboratory with an Elekta Triux (Megin, Finland) scanner.
* The stimulation signal was a square-wave pulse with 2Hz frequency and duration of 0.2ms.
* An ISI (inter-stimulus interval) of 500ms with a variation of ±20ms in order to be able to average out time-locked noise to the stimulation, while remaining unnoticeable by the subject.
* The stimulation was performed on the left hand/wrist, for two minutes, with a Digitimer DS7A stimulator. An electrode was placed on the hand/wrist while current value was tuned to match the motor threshold of the subject on the stimulated hand, with a result of 10~12mA approximately.
* Recordings were performed with a 1kHz sampling rate. Continuous HPI was disabled during these recordings. High-pass filters were set to DC for MEG channels and 0.03Hz for EEG channels.
* All files underwent a MaxFilter (version 2.3.13) tsss post-processing.
==== Files ====
The dataset we distribute with this tutorial follows the [[http://bids.neuroimaging.io|Brain Imaging Data Structure (BIDS)]] standard for neuroimaging data organization. The files that will be imported in this tutorial are the following:
'''sample_fem'''/'''sub-fem01'''/: Raw data for subject fem01
* '''ses-meg'''/: Simultaneous recordings of MEG and EEG.
* '''sub-fem01_ses-meg_task-mediannerve_run-01_proc-tsss_meg.fif'''
* '''ses-mri'''/: Imaging exams.
* '''anat'''/'''sub-fem01_ses-mri_T1w.nii.gz''': T1-weighted MRI
* '''anat'''/'''sub-fem01_ses-mri_T2w.nii.gz''': T2-weighted MRI
* '''dwi'''/'''sub-fem01_ses-mri_dwi.*''': Diffusion-Weighted Imaging (DWI)
==== License ====
'''CC0''': This dataset is distributed in the public domain.
<)>>
== Tutorials using this dataset ==
* [[Tutorials/FemMedianNerve|FEM median nerve]]