Real-time head-tracking for adjusting head position

Authors: Elizabeth Bock, Soheila Samie

This program is designed to capture head position information from the CTF MEG system and display a scalp surface relative to the sensor helmet. The acquisition workstation runs the FieldTrip program acq2ftx and a second computer runs Brainstorm and the FieldTrip buffer program. The acquisition workstation and the second computer need to be connected to each other either across the same network or a direct computer-to-computer network connection.

System Setup

On the second computer, Brainstorm and Fieldtrip should be installed in the same location.

On the MEG acquisition workstation, acq2ftx should be installed. Please see http://fieldtrip.fcdonders.nl/development/realtime for more information about the real-time FieldTrip buffer.

How to use

On the second computer, start Brainstorm

Start Brainstorm Headtracking Program

headtracking_start.png

Start ACQ Headtracking

example:

acq2ftx '10.0.0.2’:1972:RE:1:HLC0011,HLC0012,HLC0013,HLC0021,HLC0022,HLC0023,HLC0031,HLC0032,HLC0033

where 10.0.0.2 should be the IP address of the second computer.

acq2ftx_start.jpg

To Stop the ACQ Headtracking Program:

Realtime Alignment

This allows for the re-alignment of a subject's current head position to an original position between recordings. This can be useful when one is interested in analyzing data in the sensor space. The goal would be to properly adjust the subject at the beginning of a session, then ask the subject to return to that position for each subsequent recording by providing feedback about head location. Here is how to use this feature:

headtracking_different_positions.jpg headtracking_similar_positions.jpg





Feedback: Comments, bug reports, suggestions, questions
Email address (if you expect an answer):