BFC Correction Tool

The BFC correction tool is a graphical user interface for manually guiding the bias field correction in the MRI images. It is an addon to BrainSuite's bias-field correction in case the MRI image requires more accurate bias-field correction and uses tissue classification results from BrainSuite.

BFC Correction Tool allows users to manually select points corresponding to gray matter, white matter and CSF. Then, the bias field is estimated by finding a smooth scaling function such that the selected points are at approximately median intensity of the corresponding tissue types.

attachment:bfc_corr_tool.png attachment:bfc_corrector_anim.gif

Here are the step by step instuctions for using the BFC correction tool.

  1. As BFC Correction Tool uses BrainSuite generated tissue classification file, complete BrainSuite extraction sequence till Tissue Classification. The subject folder should have fname.pvc.label.nii.gz and fname.bfc.nii.gz for BFC Correction Tool to work successfully.

  2. Download the tool from links given below and unzip the files into a folder.
  3. In Windows, double click on gui_bias_correct.exe. In MAC, from the terminal, run gui_bias_correct.sh. This step will open file selection menu. Open the BrainSuite generated fname.bfc.nii.gz file to be corrected. This will open the user interface as shown above.

  4. In the interface, find a region by scrolling through slices where you want to correct the bias field. In this region, select a point using the crosshair and press the tissue type button (WM, GM or CSF). Repeat this to select a few points (4-5) in different regions of bias field issues. The region of influence of the control points can be changed by changing values in the bottom box (1500 default).
  5. When you are done selecting the points, press Corr Bias button. This will perform the bias field correction. This step may take 2-3 min. Once it is done, it will open a window to show the corrected image and the bias field that corrects the image.

  6. The corrected image will be saved in the same directory as the original image with the file name fname.corr.nii.gz. The estimated bias filed will also be saved in the same directory with the file name fname.bias.nii.gz.

  7. Close the gui. You can now open the corrected image in BrainSuite and redo the BFC to correct the small bias field issue that were left uncorrected, and proceed with rest of the BrainSuite sequence.

BFC correction tool requires matlab MCR for R2012a which can be downloaded from here.

Authors: Anand A. Joshi, Chitresh Bhushan

   

Resources/bfc_correction_tool (last edited 2016-05-28 00:03:42 by ?AnandJoshi)