19242
Comment:
|
19656
|
Deletions are marked like this. | Additions are marked like this. |
Line 4: | Line 4: |
<<TableOfContents(2,2)>> |
|
Line 5: | Line 7: |
==== Documentation ==== * New online tutorials (work in progress) |
|
Line 11: | Line 10: |
==== Statistics ==== * Implementation of new parametric and non-parametric tests (work in progress) ==== Documentation ==== * Standard workflows for different types of data and experiments (work in progress) |
|
Line 12: | Line 17: |
* Significance thresholding of the connectivity matrices (2016) | * Significance thresholding of the connectivity matrices (not started) |
Line 22: | Line 27: |
* Nicer topographies (similar to EEGLAB plots) | * Nicer topographies with circle around 2DDisc (similar to EEGLAB plots) |
Line 26: | Line 31: |
* Make the surface on which the values are interpolated simpler | |
Line 27: | Line 33: |
* Montages: * Separators (" : MLC11" already works, could be just " : "), should add an empty space. |
|
Line 32: | Line 40: |
* Add support for montages | |
Line 33: | Line 42: |
* Show easily the maximum value at the current time point | |
Line 34: | Line 44: |
* Events: Change the category of a selected event easily, instead of deleting/marking new | |
Line 36: | Line 47: |
* Bad channels specified at the program level (for sites that have permanent bad channels: AS) * Images of amplitude: [sensor x time], [trial x time], scout: [trial x time] * Can be done with Matrix > View as image: extract cluster, concatenate for all trials * Filtering: * Use short FIR filters instead of IIR for bandpass, to limit the ringing * Or allow the users to edit the LowStop parameter in bst_bandpass. * Show easily recordings maximum/values in the file viewer |
|
Line 47: | Line 50: |
* Generalize the user of the units (field .Units): Rewrite processes to save the units correctly | * Allow FieldTrip functions in compiled version * Generalize the use of the units (field .DisplayUnits): Rewrite processes to save the units correctly |
Line 49: | Line 53: |
* Manage multiple custom colormaps | |
Line 57: | Line 60: |
* Smooth display from figure_image (ERPimage, raster plot...) | |
Line 60: | Line 64: |
* t-tests on connectivity measures * Check why our Hilbert implementation has huge edge effects |
* Stat tests on connectivity measures |
Line 63: | Line 66: |
* Review by Jan-Mathijs: http://journal.frontiersin.org/article/10.3389/fnsys.2015.00175/full | |
Line 67: | Line 71: |
* Multi-tapers? | |
Line 97: | Line 100: |
* PAC maps: Display all sensors at once (like TF and DynamicPAC) | |
Line 103: | Line 107: |
* Connect NxN: Display as time series > Display warning before trying to open too many signals | |
Line 106: | Line 111: |
Line 117: | Line 123: |
* EEGLAB recommends ICA + trial rejection + ICA again: Impossible right now with Brainstorm<<BR>>(http://sccn.ucsd.edu/wiki/Chapter_09:_Decomposing_Data_Using_ICA) | |
Line 131: | Line 138: |
* Rewrite to have the same input as coherence * Normalize with the total power (TF/sum(TF,3)) |
* Rewrite to have the same input as coherence (frequency resolution instead of window length) * Use the progress bar |
Line 138: | Line 145: |
* Do not display the intermediate files | |
Line 142: | Line 148: |
* Induced calculation: Avg(Power(TF(trials - Avg(Trials)))): <<BR>>Add option "Remove evoked response from each trial" * Standardize using: diff before calculation + cumsum (checkbox "flatten data") * Frequency bands: extended syntax (ex: [2 3 4], 10:5:90, ...) * Display logs as negative * Difference of power displayed in log: problems (Soheila) |
* Multi-tapers * Matching pursuit: http://m.jneurosci.org/content/36/12/3399.abstract?etoc * Bug: Display logs as negative * Bug: 3D figures: Colormaps with "log" option doesn't work * Bug: Difference of power displayed in log: problems (Soheila) |
Line 153: | Line 159: |
* 3D figures: Colormaps with "log" option doesn't work | * Extend clusters tab to display of TF to overlay TF signals (Svet) * TF on scouts: Add progress bar when extracting all the scouts time series (can be long) |
Line 155: | Line 162: |
* Detection of bad segments in the RAW files (Beth) | |
Line 158: | Line 164: |
* Allow the detection on differences of signals (bipolar montages) * Average: * Remember how many trials were used per channel * Save standard deviation * Display standard deviation as a halo around the time series |
|
Line 180: | Line 181: |
* Use new Matlab functions: movmean, movsum, movmedian, movmax, movmin, movvar, movstd | |
Line 184: | Line 186: |
* Matrix files: * Group matrix files => allow to process matrix files by trial types * Allow to be dependent from other files |
* Matrix files: Allow to be dependent from other files |
Line 211: | Line 211: |
* Export as .nii volume: doesn't work * Project individual volume grids on a template |
|
Line 213: | Line 215: |
* Read easily dipole coordinates: Click on one selects it and open the panel Get coordinates | |
Line 236: | Line 237: |
* When deploying to other conditions: Apply destination SSP (NoiseCov = SSP.NoiseCov.SSP' ) | |
Line 238: | Line 238: |
* Simulation: synthesize pseudo data-files from a cortex patch (duration, amplitude, noise) | |
Line 240: | Line 239: |
* EEG Source modeling: Manage references and bipolar montages properly (maybe not necessary) * MEG source modeling: Do reconstruction only for a subset of sensors for estimating dipoles? * Processes compute head model and sources: Additional option to set the file comment |
* Beamformers from FieldTrip (LCMV, SAM) |
Line 258: | Line 255: |
* Bug: Head surface generated with Brainstorm is too large | |
Line 261: | Line 257: |
* BrainVISA: Add support for MarsAtlas (Guillaume A) | |
Line 272: | Line 269: |
* Optimize computation interpolation MRI-surface (tess_tri_interp) * Render surface envelope in the MRI as a thin line instead of the full interpolation matrix |
|
Line 273: | Line 272: |
* Smooth surface: Fix little spikes to irregularities in the mesh | * Smooth surface: Fix little spikes due to irregularities in the mesh |
Line 286: | Line 285: |
* Problem t-test on unconstrained sources: (convert to flat + Z-score) => AnneSo * Waiting for test from Dimitrios * Question of Gaussianity of the samples: take a subset of samples + Kolmogorov-Smirnov / Shapiro-Wilk test * http://fr.wikipedia.org/wiki/Test_de_Shapiro-Wilk * http://stats.stackexchange.com/questions/362/what-is-the-difference-between-the-shapiro-wilk-test-of-normality-and-the-kolmog * http://www.mathworks.fr/fr/help/symbolic/mupad_ug/perform-shapiro-wilk-test.html * http://www.mathworks.fr/fr/help/symbolic/mupad_ref/stats-swgoft.html * http://stackoverflow.com/questions/14383115/shapiro-wilk-test-in-matlab * Stat FieldTrip: impossible to do Abs(Mean(Sources)) => Is it a problem? |
* Problem t-test on unconstrained sources: (convert to flat + Z-score) * FieldTrip implementation: * Add logic of bad channels individually per sensor instead of removing completely all the channels that are marked as bad in at least one trial * Use SurfStat: Impements interesting things, like an analytical cluster-based p-value correction (Random-field theory which is used in SPM) - Peter |
Line 296: | Line 290: |
* In Stat tab: Correction by temporal extension (display only if effect longer than a given input in ms) | |
Line 298: | Line 293: |
* FieldTrip structures: Import/Export continuous recordings and non-averaged trials. | * 4D file format: * Reference gradiometers: Keep the orientation of the first or second coil? * Reference gradiometers: Add the sensor definition from coil_def.dat * Validate with phatom recordings that noise compensation is properly taken into account * References at too far from the head sensors in Marseille 4D system * The noise compensation is considered to be always applied on the recordings, not sure this assumption is always correct |
Line 305: | Line 305: |
* Allow epoched files with recordings saved in external files (now external files implies continuous recordings) | * Allow epoched files with recordings saved in external files |
Line 309: | Line 309: |
* Use new Matlab functions readtable/writetable (2006b): for Excel and text files | |
Line 311: | Line 312: |
* Workflows FieldTrip: http://www.fieldtriptoolbox.org/faq/what_types_of_datasets_and_their_respective_analyses_are_used_on_fieldtrip | |
Line 313: | Line 315: |
* Add Help buttons and menus (in popups, dialog windows...) => Links to the website. | * Update the list of features and link in the Introduction page |
Line 315: | Line 317: |
* EEG/Epilepsy: Rewrite scripts + update contents (with Geneva2015 walkthrough) | |
Line 316: | Line 319: |
* Auditory: Finish scripts | |
Line 319: | Line 321: |
* MEG connectome | * MEG steady-state / high-gamma visual * Intra-cranial recordings * MEG connectome (impossible without the head shapes) |
Line 322: | Line 326: |
* Intra-cranial recordings | |
Line 325: | Line 328: |
* SSP: Create projector from any topography figure (right-click > Create SSP) | |
Line 326: | Line 330: |
* Sources: Model evaluation (by simulating recordings) | |
Line 328: | Line 331: |
* Modify a structure manually: Export to Matlab/Import from Matlab * File manipulation: file_short, file_fullpath, in_bst_*... * Description of all fields in MRI and surfaces |
* Scripting: Modify a structure manually: Export to Matlab/Import from Matlab * Scripting: File manipulation: file_short, file_fullpath, in_bst_*... * Script tutorials: ask what folder contains the tutorial datasets |
Line 354: | Line 357: |
* Out of memory errors on Win 32bits (restart Matlab) * Matlab 2014b bug with rmdir/movefile: Enter but never returns from the call |
|
Line 360: | Line 361: |
* Change of default anatomy does not reset the interpolation matrices in all the subjects. * After projecting sources once from subject to default anat, the interpolation is saved and not updated. Interpolations need to be removed manually before projecting again on a new template. |
|
Line 375: | Line 378: |
* Replace handle "0" with bst_get('groot') * At the end of bst_startup in compiled mode, replace loop with waitfor(jFrame) |
|
Line 378: | Line 379: |
* Optimize MRI viewer with patch() instead of image() |
What's next
A roadmap to the future developments of Brainstorm.
Contents
Current topics
Source modeling
- Implementation of a new unified minimum norm/beamformer framework (work in progress)
Statistics
- Implementation of new parametric and non-parametric tests (work in progress)
Documentation
- Standard workflows for different types of data and experiments (work in progress)
Functional connectivity
- Significance thresholding of the connectivity matrices (not started)
Computation
- Removing the dependence to the Java interface to run in headless mode (not started)
- Interacting directly with distributed computing systems (not started)
Recordings
- 2D topographies:
- Nicer topographies with circle around 2DDisc (similar to EEGLAB plots)
Standardized plots (using FieldTrip .lay files?)
- Aligned on the midline at least
- Contour lines sometimes messed up with Elekta recordings
- Make the surface on which the values are interpolated simpler
- MEG/EEG registration: Apply the same transformation to multiple runs
- Montages:
- Separators (" : MLC11" already works, could be just " : "), should add an empty space.
- 2DLayout:
- Use the same standard positions, too much space between sensors (Recordings + TF)
- Overlay multiple conditions
RAW files: Doesn't work when changing page => need refresh of GlobalData.Preferences.TopoLayoutOptions.TimeWindow
- Same shortcuts as the raw file viewer (right-click + move for gain)
- Add support for montages
- RAW file viewer:
- Show easily the maximum value at the current time point
- Pre-load next page of recordings
- Events: Change the category of a selected event easily, instead of deleting/marking new
- Events: advanced process for recombining.
Example: http://www.erpinfo.org/erplab/erplab-documentation/manual/Binlister.html
Interface
- Start Brainstorm without Java (-nodesktop)
Allow FieldTrip functions in compiled version
Generalize the use of the units (field .DisplayUnits): Rewrite processes to save the units correctly
- Colormaps:
- Allow brightness/contrast manipulations on the custom colormaps
- Create a colormap similar to MNE, where extrema are bright
- Global colormap max: Should get the maximum across all the open files
- Open new figures as tab (docked in the Figures window)
- Copy figures to clipboard (with the screencapture function)
- Removing all the CTRL and SHIFT in the keyboard shortcuts
- Display warning before opening files that are too big
- Smooth display from figure_image (ERPimage, raster plot...)
Connectivity
- Thresholding the connectivity matrices
- Stat tests on connectivity measures
- Connectivity on unconstrained sources: how to group the three orientations?
Review by Jan-Mathijs: http://journal.frontiersin.org/article/10.3389/fnsys.2015.00175/full
- Connectivity based on band limited power (Sylvain):
- Compute Hilbert/Bandpass + correlation of the envelopes
- Bandpass envelopes before computing correlations?
- Compute Hilbert(sensors) and then project to source space?
- Graph view:
- Does not display negative values correctly (correlation or difference of coherence)
- Re-write using pure Matlab code and smoothed graphics
- Fixed scales for intensity sliders
- Text bigger
- Too much data in appdata
- Fixed scales for intensity sliders
- Add "=" shortcut for having graphs with similar configurations
- Disable zoom in one region (serious bugs)
- NxN on sensors: does not place the sensors correctly in space
- Coherence:
- Average cross-spectra instead of concatenating epochs (to avoid discontinuities)
- Granger:
- Crashes sometimes: improve stability
- Re-write and optimize code
- Add progress bar
- PLV:
- Add p-values
- Remove evoked
- Optimize code
- Add time integration
- Unconstrained sources
- PAC:
- Add input TF , to disconnect TF decomposition and PAC computation (Peter)
- Refine frequency vector of low frequencies
- How many central frequencies to use in bst_pac?
- Change filters: no chirplet functions
- bst_freqfilter: Use nfcomponents like in bst_pac
- Esther recommended a larger frequency binning of the PAC estimation
- PAC maps: Display all sensors at once (like TF and DynamicPAC)
- Time-resolved correlation/coherence: Display as time bands
- Other metrics:
- Coherence by bands: bst_coherence_band_welch.m
- Granger by bands: bst_granger_band.m
- Inter-trial coherence
Tutorial coherence [1xN] : Reproduce FieldTrip results?
Connect NxN: Display as time series > Display warning before trying to open too many signals
Processes
- Optimize pipeline editor speed: Opening the window and the showing menu "Add process" are slow
- ICA:
- Exploration: Add window with spectral decomposition (useful for muscle artifacts)
Comparison JADE/Infomax:
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0030135- Add methods: SOBI, Fastica, AMICA/CUDICA (recommended by S Makeig)
Dimension reduction with PCA adds artifacts: Not done by default in EEGLAB
Contact: Stephen Shall Jones ( shall-jones@infoscience.otago.ac.nz )
Student Carl Leichter detailed this in his thesis- S Makeig: Use ICA to select the IC of interest instead of only removing artifacts
- Display of spectrum for components (PSD/FFT)
- Use FastICA (algo crashing)
- Understand why EEG/Epilepsy tutorial data crashes if we don't limit the number of components
- Add components preselection: Correlation with EOG/ECG
- Import ICA matrices available in EEGLAB .set files
EEGLAB recommends ICA + trial rejection + ICA again: Impossible right now with Brainstorm
(http://sccn.ucsd.edu/wiki/Chapter_09:_Decomposing_Data_Using_ICA)
- Use Matlab Coder to optimize some processes: Wavelets, bandpass filter, sinusoid removal
- Allow processes in Python and Java
- SSP:
Display warning if changing the ChannelFlag while there is a Projector applied
Show where the attenuation is projected:
(sum(IK,2)-sum(SSP(k,:)*IK,2)./sum(IK,2)
- Bandpass:
- Offer option: bst_bandpass_fft / bst_bandpass_filter
- Rewrite without the forced low-pass filter at Fs/3
- Show warning when using inappropriate high-pass filter (precision too high)
- Use FIR filter
- Spectral flattening (John):
- ARIMA(5,0,1): Apply on the signal before any frequency/connectivity/PAC analysis
- PSD:
- Rewrite to have the same input as coherence (frequency resolution instead of window length)
- Use the progress bar
Remove line noise: http://www.nitrc.org/projects/cleanline
- Band-limited power envelope
- Reports:
- Save as HTML / PDF
- Pipeline editor:
- Add loops over subjects/conditions/trial groups
- Time-frequency:
- Multi-tapers
Matching pursuit: http://m.jneurosci.org/content/36/12/3399.abstract?etoc
- Bug: Display logs as negative
- Bug: 3D figures: Colormaps with "log" option doesn't work
- Bug: Difference of power displayed in log: problems (Soheila)
- 2D Layout in spectrum
- Make much faster and more memory efficient (C functions coded by Matti ?)
- TF scouts: should display average of TF maps
- Impossible to keep complex values for unconstrained sources
- Pad short epochs with zero values for getting lower frequencies
- Hilbert with time bands very slow on very long files (eg. 3600s at 1000Hz) because the time vector is still full (10^7 values): save compressed time vector instead.
- Extend clusters tab to display of TF to overlay TF signals (Svet)
- TF on scouts: Add progress bar when extracting all the scouts time series (can be long)
- Artifact detection:
- Artifact rejection like SPM: if bad in 20%, bad everywhere
- Test difference between adjacent samples
- Co-registration of MEG runs:
- SSP: Group projectors coming from different files
- Finish validation of the method
- Apply to continuous recordings for correcting head movements
- Resample continuous files
- Other processes:
- Moving average
- Max
- Median
- Significance test (Dimitrios, Leo)
- Spatial smoothing: check / document parameters
Contact sheets & movies: use average of time windows instead of single instants, for each picture.
- Optical flow
- Simulation:
Fix units in simulation processes => no *1e-9 in "simulate recordings"
- Use "add noise" process from Hui-Ling (in Work/Dev/Divers)
- Use field process field "Group" to separate Input/Processing/Output options
- Use new Matlab functions: movmean, movsum, movmedian, movmax, movmin, movvar, movstd
Database
- Sort files by comment
- MEG protocols: More flexible organization of the database; sub-conditions to allow different runs X different conditions.
- Matrix files: Allow to be dependent from other files
- Add notes in the folders (text files, visible as nodes in the tree)
- Screen captures: save straight to the database
- Rename multiple files
- Default headmodel lost when reloaded: Keep selection on the hard drive (in brainstormstudy.mat)
Distributed computing
Options from FieldTrip:
Loose collection of computers: https://github.com/fieldtrip/fieldtrip/tree/master/peer
Alternative, with less limitations: http://research.cs.wisc.edu/htcondor/
Single multicore machine: https://github.com/fieldtrip/fieldtrip/tree/master/engine
Batch system: https://github.com/fieldtrip/fieldtrip/tree/master/qsub
Documentation: http://fieldtrip.fcdonders.nl/faq#distributed_computing_with_fieldtrip_and_matlab
Source modeling
- Mixed head models:
- Project to templates (scouts or source maps)
Create scout form maximum doesn't work (menu Sources > Max value)
- Display in MRI doesn't work
- Smooth display: do not smooth subcortical structures
- Export as .nii volume: doesn't work
- Project individual volume grids on a template
- Dipoles:
- panel_dipoles: Doesn't work with multiple figures
- Panel Get coordinates: Add button "find maximum"
- Stenroos 2014 paper: Include the following methods
Inner and outer skull surfaces generator from FieldTrip (needs SPM)
- Nolte corrected-sphere model (good model re:Alex)
- Fast BEM models
- Visualize Beamformer results:
- Read CTF SAM .svl
- Display as layers in the MRI viewer
- Unconstrained sources:
- Stat and connectivity: what to do? (re-send email John+Sylvain)
- Overlapping spheres: improve the estimation of the spheres for the frontal lobes
- Volume grid:
- Test volume sources with all the subsequent processes (timefreq, stat...)
- Optimize: 3D display (better than 9x9 cubes)
- Optimize: vol_dilate (with 26 neighbors)
- Magnetic extrapolation: Do the same thing with EEG
- Noise covariance matrix:
- Display with figure_image()
- Storage of multiple noise covariance matrices (just like the head models)
- Always save as full, then at inversion time, we can decide between full, heteroskedastic (diagonal) or homoskedastic (i.i.d, scalar)
Problem of having inividual trials + averages in the condition => Display warning or not?
- Save nAvg in noisecov file, to make it easier to scale to other recordings
Sources on surface: Display peak regions over time (time = color) => A.Gramfort
Calculate ImagingKernel * Gain for a scout
Beamformers from FieldTrip (LCMV, SAM)
- Time-frequency beamformers:
- Band-pass everything in different frequency bands + Source estimation + TF
- Ask data to Sarang where he sees effects that cannot be extracted with MN followed by TF
- Process "Extract scouts time series": Add PCA option (replace isnorm with choice PCA/Norm)
- BEM: Fix unstable results when one vertex is too close from the layers (5mm ?)
- Hui-Ling beamformers:
- More explanations about what is in NAI and Spatial filters
Explain that is this is better to study effects extended in time (Ntime > Nsensors)
- Group LCMV+MCB
- Condition LEFT median nerve: very bad results
Menu Sources > Simulate recordings:
- Do not close the 3D figures after generating a new file
- Add a process equivalent to this menu
Anatomy
MNI coordinates: Extend to non FreeSurfer volumes (BrainSuite volumes that are not 256x256x256)
- Project all sub-cortical structures to default anatomy (check code from Denis S)
BrainVISA: Add support for MarsAtlas (Guillaume A)
- Add cerebellum to default model generated with "Import FS anatomy"
- Import MRIs with different resolutions: re-interpolate automatically
- Edit fiducials: Replace 6 text boxes with 1 for easy copy-paste (see fiducials.m)
- Warping: Scale option has to be fixed, it is currently very unstable
- Scouts:
- Display edges in the middle of the faces instead of the vertices
- Display scouts in a tree: hemisphere, region, subregion
- Downsample to atlas: allow on timefreq/connect files
- Sort scouts by region in process options
Menu head model > Copy to other conditions/subjects (check if applicable first)
- Generate mixed density surfaces
- Optimize computation interpolation MRI-surface (tess_tri_interp)
- Render surface envelope in the MRI as a thin line instead of the full interpolation matrix
- Major bug when importing surfaces for an MRI that was re-oriented manually
- Smooth surface: Fix little spikes due to irregularities in the mesh
- Add eyes models to attract eye activity
ECOG/SEEG
- Co-register MRI and CT for electrodes marking in the MRI Viewer
- Import/export electrodes positions in MNI/SCS/MRI coordinates
- Display SEEG+ECOG contacts at the same time
Problem of difference between RAS and TkRegRAS: http://neuroimage.usc.edu/forums/showthread.php?1958-SEEG-electrodes-and-subject-s-anatomy-are-not-alligned
Statistics
- ANOVA: Use LENA functions(?)
- Output = 1 file per effect, all grouped in a node "ANOVA"
- Display several ANOVA maps (from several files) on one single figure, using a "graphic accumulator", towards which one can send any type of graphic object
- Problem t-test on unconstrained sources: (convert to flat + Z-score)
FieldTrip implementation:
- Add logic of bad channels individually per sensor instead of removing completely all the channels that are marked as bad in at least one trial
Use SurfStat: Impements interesting things, like an analytical cluster-based p-value correction (Random-field theory which is used in SPM) - Peter
- PLS: Partial Least Squares
- In Stat tab: Correction by temporal extension (display only if effect longer than a given input in ms)
Input / output
- 4D file format:
- Reference gradiometers: Keep the orientation of the first or second coil?
- Reference gradiometers: Add the sensor definition from coil_def.dat
- Validate with phatom recordings that noise compensation is properly taken into account
- References at too far from the head sensors in Marseille 4D system
- The noise compensation is considered to be always applied on the recordings, not sure this assumption is always correct
- EEG File formats:
EEG CeeGraph
- EGI: Finish support for epoched files (formats 3,5,7)
- BCI2000 Input (via EEGLAB plugin)
- EEGLAB import:
- Support for binary AND epoched files (now it's one or the other)
- Allow epoched files with recordings saved in external files
- BST-BIN: Add compression
- Review raw on all the file formats (ASCII EEG and Cartool missing)
- gTec EEG recordings: Read directly from the HDF5 files instead of the Matlab exports.
- Use new Matlab functions readtable/writetable (2006b): for Excel and text files
Distribution & documentation
Workflows FieldTrip: http://www.fieldtriptoolbox.org/faq/what_types_of_datasets_and_their_respective_analyses_are_used_on_fieldtrip
Reference tutorials on Google scholar + ResearchGate
- Cleaning threads on the forum
- Update the list of features and link in the Introduction page
- Finish existing tutorials:
- EEG/Epilepsy: Rewrite scripts + update contents (with Geneva2015 walkthrough)
- Dipoles
- Group MEM/Epilepsy + Epilepsy tutorials
- New tutorials:
- MEG steady-state / high-gamma visual
- Intra-cranial recordings
- MEG connectome (impossible without the head shapes)
- Scrambled faces (SPM/MNE-Python)
- Coherence (cortico-muscular ?)
- Co-register MEG runs (Beth)
- Missing in the introduction tutorials:
SSP: Create projector from any topography figure (right-click > Create SSP)
- Volume scouts
- Time-frequency: Description of "log freq scale" option
- Scripting: Modify a structure manually: Export to Matlab/Import from Matlab
- Scripting: File manipulation: file_short, file_fullpath, in_bst_*...
- Script tutorials: ask what folder contains the tutorial datasets
- Missing in tutorial "Export to SPM": Add section "Compare with Brainstorm"
- Missing in page "Cite Brainstorm": Add all the methods used in the software
Current bugs
- Screen capture:
- Bug on Win8/Win10: doesn't capture the correct part of the screen
- Window managers with fading effect: captures the top window
- Image viewer:
- Difficult to get to 100%
- Buggy on some systems
- 2DLayout:
- (TF) Images are too far apart with EEG 20 channels
- (time series) Sometimes the lines are not visible
- (time series) Does not work when DC offset is not removed
- Progress bar:
- Doesn't close properly on some Linux systems
- Focus requests change workspace when processing constantly (Linux systems)
- MacOS bugs:
- Buttons {Yes,No,Cancel} listed backwards
- Record tab: Text of epoch number is too big
- Colormap menus: Do not work well on compiled MacOSX 10.9.5 and 10.10
- Matlab bugs:
- Interface looks small on screens with very high resolutions: Reduce the resolution
- Event markers are not visible anymore with the sequence: Open MEG, open EOG, close MEG
- in_bst_data_multi: If trials have different sizes, output is random (the one of the first file)
- Edit scout in MRI: small modifications cause huge increase of the scout size
- Canolty maps computation: Fix progress bar
- Change of default anatomy does not reset the interpolation matrices in all the subjects.
- After projecting sources once from subject to default anat, the interpolation is saved and not updated. Interpolations need to be removed manually before projecting again on a new template.
Geeky programming details
- Hide Java panels instead of deleting them
- Interpolations: Use scatteredInterpolant, griddedInterpolant, triangulation.nearestNeighbor (2014b)
- bst_warp and channel_project: Use tess_parametrize_new instead of tess_parametrize
- Shared kernels: "get bad channels" operation in a different way (reading all the files is too slow)
- Optimize bst_get:
- Now study and subject have necessarily the same folder name
- Replace big switch with separate functions
- Progress bar:
- Add different levels (to handle sub-processes)
- Make work correctly with RAW on resting tutorial
- Uniformize calls in bst_process/Run
- Add a "Cancel" button
- Fix all the 'todo' blocks in the code
- Error message: Add a link to report directly the bug on the forum