| Size: 20534 Comment:  | Size: 20970 Comment:  | 
| Deletions are marked like this. | Additions are marked like this. | 
| Line 303: | Line 303: | 
| * 4D file format: * Reference gradiometers: Keep the orientation of the first or second coil? * Reference gradiometers: Add the sensor definition from coil_def.dat * Validate with phatom recordings that noise compensation is properly taken into account * References at too far from the head sensors in Marseille 4D system * The noise compensation is considered to be always applied on the recordings, not sure this assumption is always correct | |
| Line 304: | Line 310: | 
| * Import/Export continuous recordings and non-averaged trials. | * Import/Export continuous recordings | 
What's next
A roadmap to the future developments of Brainstorm.
Contents
Current topics
Source modeling
- Implementation of a new unified minimum norm/beamformer framework (work in progress)
Statistics
- Implementation of new parametric and non-parametric tests (work in progress)
Documentation
- Standard workflows for different types of data and experiments (work in progress)
Functional connectivity
- Significance thresholding of the connectivity matrices (not started)
Computation
- Removing the dependence to the Java interface to run in headless mode (not started)
- Interacting directly with distributed computing systems (not started)
 
Recordings
- 2D topographies: - Nicer topographies with circle around 2DDisc (similar to EEGLAB plots)
- Standardized plots (using FieldTrip .lay files?) 
- Aligned on the midline at least
- Contour lines sometimes messed up with Elekta recordings
- Make the surface on which the values are interpolated simpler
 
- MEG/EEG registration: Apply the same transformation to multiple runs
- Montages: - Allow to set the color for each channel separately
- Allow the superposition of channels (NIRS)
- Separators (" : MLC11" already works, could be just " : "), should add an empty space.
 
- 2DLayout: - Use the same standard positions, too much space between sensors (Recordings + TF)
- Overlay multiple conditions
- RAW files: Doesn't work when changing page => need refresh of GlobalData.Preferences.TopoLayoutOptions.TimeWindow 
- Same shortcuts as the raw file viewer (right-click + move for gain)
- Add support for montages
 
- RAW file viewer: - Show easily the maximum value at the current time point
- Pre-load next page of recordings
- Events: Change the category of a selected event easily, instead of deleting/marking new
- Events: advanced process for recombining.
- Example: http://www.erpinfo.org/erplab/erplab-documentation/manual/Binlister.html 
 
- Filtering: - Use short FIR filters instead of IIR for bandpass, to limit the ringing (bad for Hilbert as well)
- Or allow the users to edit the LowStop parameter in bst_bandpass 
 
- Bad channels specified at the program level (for sites that have permanent bad channels: AS)
Interface
- Start Brainstorm without Java (-nodesktop)
- Allow FieldTrip functions in compiled version 
- Generalize the user of the units (field .Units): Rewrite processes to save the units correctly
- Colormaps: - Allow brightness/contrast manipulations on the custom colormaps
- Create a colormap similar to MNE, where extrema are bright
- Global colormap max: Should get the maximum across all the open files
 
- Open new figures as tab (docked in the Figures window)
- Copy figures to clipboard (with the screencapture function)
- Removing all the CTRL and SHIFT in the keyboard shortcuts
- Display warning before opening files that are too big
- Smooth display from figure_image (ERPimage, raster plot...)
Connectivity
- Thresholding the connectivity matrices
- Stat tests on connectivity measures
- Check why our Hilbert implementation has huge edge effects
- Connectivity on unconstrained sources: how to group the three orientations?
- Connectivity based on band limited power (Sylvain): - Compute Hilbert/Bandpass + correlation of the envelopes
- Bandpass envelopes before computing correlations?
- Compute Hilbert(sensors) and then project to source space?
 
- Multi-tapers?
- Graph view: - Does not display negative values correctly (correlation or difference of coherence)
- Re-write using pure Matlab code and smoothed graphics
- Fixed scales for intensity sliders
- Text bigger
- Too much data in appdata
- Fixed scales for intensity sliders
- Add "=" shortcut for having graphs with similar configurations
- Disable zoom in one region (serious bugs)
- NxN on sensors: does not place the sensors correctly in space
 
- Coherence: - Average cross-spectra instead of concatenating epochs (to avoid discontinuities)
 
- Granger: - Crashes sometimes: improve stability
- Re-write and optimize code
- Add progress bar
 
- PLV: - Add p-values
- Remove evoked
- Optimize code
- Add time integration
- Unconstrained sources
 
- PAC: - Add input TF , to disconnect TF decomposition and PAC computation (Peter)
- Refine frequency vector of low frequencies
- How many central frequencies to use in bst_pac?
- Change filters: no chirplet functions
- bst_freqfilter: Use nfcomponents like in bst_pac
- Esther recommended a larger frequency binning of the PAC estimation
- PAC maps: Display all sensors at once (like TF and DynamicPAC)
 
- Time-resolved correlation/coherence: Display as time bands
- Other metrics: - Coherence by bands: bst_coherence_band_welch.m
- Granger by bands: bst_granger_band.m
- Inter-trial coherence
 
- Tutorial coherence [1xN] : Reproduce FieldTrip results? 
- Connect NxN: Display as time series > Display warning before trying to open too many signals 
Processes
- Optimize pipeline editor speed: Opening the window and the showing menu "Add process" are slow
- ICA: - Exploration: Add window with spectral decomposition (useful for muscle artifacts)
- Comparison JADE/Infomax: 
 http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0030135
- Add methods: SOBI, Fastica, AMICA/CUDICA (recommended by S Makeig)
- Dimension reduction with PCA adds artifacts: Not done by default in EEGLAB 
 Contact: Stephen Shall Jones ( shall-jones@infoscience.otago.ac.nz )
 Student Carl Leichter detailed this in his thesis
- S Makeig: Use ICA to select the IC of interest instead of only removing artifacts
- Display of spectrum for components (PSD/FFT)
- Use FastICA (algo crashing)
- Understand why EEG/Epilepsy tutorial data crashes if we don't limit the number of components
- Add components preselection: Correlation with EOG/ECG
- Import ICA matrices available in EEGLAB .set files
- EEGLAB recommends ICA + trial rejection + ICA again: Impossible right now with Brainstorm 
 (http://sccn.ucsd.edu/wiki/Chapter_09:_Decomposing_Data_Using_ICA)
 
- Use Matlab Coder to optimize some processes: Wavelets, bandpass filter, sinusoid removal
- Allow processes in Python and Java
- SSP: - Display warning if changing the ChannelFlag while there is a Projector applied 
- Show where the attenuation is projected: 
 (sum(IK,2)-sum(SSP(k,:)*IK,2)./sum(IK,2)
 
- Bandpass: - Offer option: bst_bandpass_fft / bst_bandpass_filter
- Rewrite without the forced low-pass filter at Fs/3
- Show warning when using inappropriate high-pass filter (precision too high)
- Use FIR filter
 
- Spectral flattening (John): - ARIMA(5,0,1): Apply on the signal before any frequency/connectivity/PAC analysis
 
- PSD: - Rewrite to have the same input as coherence (frequency resolution instead of window length)
- Allow running on source files attached to continuous files (needs a lot of rewriting)
 
- Remove line noise: http://www.nitrc.org/projects/cleanline 
- Band-limited power envelope
- Reports: - Save as HTML / PDF
 
- Pipeline editor: - Add loops over subjects/conditions/trial groups
 
- Time-frequency: - Induced calculation: Avg(Power(TF(trials - Avg(Trials)))): 
 Add option "Remove evoked response from each trial"
- Standardize using: diff before calculation + cumsum (checkbox "flatten data")
- Frequency bands: extended syntax (ex: [2 3 4], 10:5:90, ...)
- Display logs as negative
- Difference of power displayed in log: problems (Soheila)
- 2D Layout in spectrum
- Make much faster and more memory efficient (C functions coded by Matti ?)
- TF scouts: should display average of TF maps
- Impossible to keep complex values for unconstrained sources
- Pad short epochs with zero values for getting lower frequencies
- Hilbert with time bands very slow on very long files (eg. 3600s at 1000Hz) because the time vector is still full (10^7 values): save compressed time vector instead.
- 3D figures: Colormaps with "log" option doesn't work
- Extend clusters tab to display of TF to overlay TF signals (Svet)
- TF on scouts: Add progress bar when extracting all the scouts time series (can be long)
 
- Artifact detection: - Artifact rejection like SPM: if bad in 20%, bad everywhere
- Test difference between adjacent samples
- Allow the detection on differences of signals (bipolar montages)
 
- Co-registration of MEG runs: - SSP: Group projectors coming from different files
- Finish validation of the method
- Apply to continuous recordings for correcting head movements
 
- Resample continuous files
- Other processes: - Moving average
- Max
- Median
- Significance test (Dimitrios, Leo)
- Spatial smoothing: check / document parameters
 
- Contact sheets & movies: use average of time windows instead of single instants, for each picture. 
- Optical flow
- Simulation: - Fix units in simulation processes => no *1e-9 in "simulate recordings" 
- Use "add noise" process from Hui-Ling (in Work/Dev/Divers)
 
- Use field process field "Group" to separate Input/Processing/Output options
- Use new Matlab functions: movmean, movsum, movmedian, movmax, movmin, movvar, movstd
Database
- Sort files by comment
- MEG protocols: More flexible organization of the database; sub-conditions to allow different runs X different conditions.
- Matrix files: Allow to be dependent from other files
- Add notes in the folders (text files, visible as nodes in the tree)
- Screen captures: save straight to the database
- Rename multiple files
- Default headmodel lost when reloaded: Keep selection on the hard drive (in brainstormstudy.mat)
Distributed computing
- Options from FieldTrip: - Loose collection of computers: https://github.com/fieldtrip/fieldtrip/tree/master/peer 
- Alternative, with less limitations: http://research.cs.wisc.edu/htcondor/ 
- Single multicore machine: https://github.com/fieldtrip/fieldtrip/tree/master/engine 
- Batch system: https://github.com/fieldtrip/fieldtrip/tree/master/qsub 
- Documentation: http://fieldtrip.fcdonders.nl/faq#distributed_computing_with_fieldtrip_and_matlab 
 
Source modeling
- Mixed head models: - Project to templates (scouts or source maps)
- Create scout form maximum doesn't work (menu Sources > Max value) 
- Display in MRI doesn't work
- Smooth display: do not smooth subcortical structures
- Export as .nii volume: doesn't work
 
- Dipoles: - panel_dipoles: Doesn't work with multiple figures
- Read easily dipole coordinates: Click on one selects it and open the panel Get coordinates
 
- Panel Get coordinates: Add button "find maximum"
- Stenroos 2014 paper: Include the following methods - Inner and outer skull surfaces generator from FieldTrip (needs SPM) 
- Nolte corrected-sphere model (good model re:Alex)
- Fast BEM models
 
- Visualize Beamformer results: - Read CTF SAM .svl
- Display as layers in the MRI viewer
 
- Unconstrained sources: - Stat and connectivity: what to do? (re-send email John+Sylvain)
 
- Overlapping spheres: improve the estimation of the spheres for the frontal lobes
- Volume grid: - Test volume sources with all the subsequent processes (timefreq, stat...)
- Optimize: 3D display (better than 9x9 cubes)
- Optimize: vol_dilate (with 26 neighbors)
 
- Magnetic extrapolation: Do the same thing with EEG
- Noise covariance matrix: - Display with figure_image()
- Storage of multiple noise covariance matrices (just like the head models)
- Always save as full, then at inversion time, we can decide between full, heteroskedastic (diagonal) or homoskedastic (i.i.d, scalar)
- Problem of having inividual trials + averages in the condition => Display warning or not? 
- Save nAvg in noisecov file, to make it easier to scale to other recordings
- When deploying to other conditions: Apply destination SSP (NoiseCov = SSP.NoiseCov.SSP' ) 
 
- Sources on surface: Display peak regions over time (time = color) => A.Gramfort 
- Calculate ImagingKernel * Gain for a scout 
- Beamformers from FieldTrip (LCMV, SAM) 
- Time-frequency beamformers: - Band-pass everything in different frequency bands + Source estimation + TF
- Ask data to Sarang where he sees effects that cannot be extracted with MN followed by TF
 
- Process "Extract scouts time series": Add PCA option (replace isnorm with choice PCA/Norm)
- BEM: Fix unstable results when one vertex is too close from the layers (5mm ?)
- Hui-Ling beamformers: - More explanations about what is in NAI and Spatial filters
- Explain that is this is better to study effects extended in time (Ntime > Nsensors) 
- Group LCMV+MCB
- Condition LEFT median nerve: very bad results
 
- Menu Sources > Simulate recordings: - Do not close the 3D figures after generating a new file
- Add a process equivalent to this menu
 
Anatomy
- MNI coordinates: Extend to non FreeSurfer volumes (BrainSuite volumes that are not 256x256x256) 
- Project all sub-cortical structures to default anatomy (check code from Denis S)
- Add cerebellum to default model generated with "Import FS anatomy"
- Import MRIs with different resolutions: re-interpolate automatically
- Edit fiducials: Replace 6 text boxes with 1 for easy copy-paste (see fiducials.m)
- Warping: Scale option has to be fixed, it is currently very unstable
- Scouts: - Display edges in the middle of the faces instead of the vertices
- Display scouts in a tree: hemisphere, region, subregion
- Downsample to atlas: allow on timefreq/connect files
- Sort scouts by region in process options
 
- Menu head model > Copy to other conditions/subjects (check if applicable first) 
- Generate mixed density surfaces
- Optimize computation interpolation MRI-surface (tess_tri_interp)
- Render surface envelope in the MRI as a thin line instead of the full interpolation matrix
- Major bug when importing surfaces for an MRI that was re-oriented manually
- Smooth surface: Fix little spikes due to irregularities in the mesh
- Add eyes models to attract eye activity
ECOG/SEEG
- Co-register MRI and CT for electrodes marking in the MRI Viewer
- Import/export electrodes positions in MNI/SCS/MRI coordinates
- Display SEEG+ECOG contacts at the same time
- Problem of difference between RAS and TkRegRAS: http://neuroimage.usc.edu/forums/showthread.php?1958-SEEG-electrodes-and-subject-s-anatomy-are-not-alligned 
Statistics
- ANOVA: Use LENA functions(?) - Output = 1 file per effect, all grouped in a node "ANOVA"
- Display several ANOVA maps (from several files) on one single figure, using a "graphic accumulator", towards which one can send any type of graphic object
 
- Problem t-test on unconstrained sources: (convert to flat + Z-score)
- FieldTrip implementation: - Add logic of bad channels individually per sensor instead of removing completely all the channels that are marked as bad in at least one trial
 
- Use SurfStat: Impements interesting things, like an analytical cluster-based p-value correction (Random-field theory which is used in SPM) - Peter 
- PLS: Partial Least Squares
- In Stat tab: Correction by temporal extension (display only if effect longer than a given input in ms)
Input / output
- 4D file format: - Reference gradiometers: Keep the orientation of the first or second coil?
- Reference gradiometers: Add the sensor definition from coil_def.dat
- Validate with phatom recordings that noise compensation is properly taken into account
- References at too far from the head sensors in Marseille 4D system
- The noise compensation is considered to be always applied on the recordings, not sure this assumption is always correct
 
- FieldTrip integration: - Import/Export continuous recordings
- Export trials with a trial definition: http://neuroimage.usc.edu/forums/showthread.php?2213 
 
- EEG File formats: - EEG CeeGraph 
- EGI: Finish support for epoched files (formats 3,5,7)
 
- BCI2000 Input (via EEGLAB plugin)
- EEGLAB import: - Support for binary AND epoched files (now it's one or the other)
- Allow epoched files with recordings saved in external files (now external files implies continuous recordings)
 
- BST-BIN: Add compression
- Review raw on all the file formats (ASCII EEG and Cartool missing)
- gTec EEG recordings: Read directly from the HDF5 files instead of the Matlab exports.
- Use new Matlab functions readtable/writetable (2006b): for Excel and text files
Distribution & documentation
- Workflows FieldTrip: http://www.fieldtriptoolbox.org/faq/what_types_of_datasets_and_their_respective_analyses_are_used_on_fieldtrip 
- Reference tutorials on Google scholar + ResearchGate 
- Cleaning threads on the forum
- Add Help buttons and menus (in popups, dialog windows...) => Links to the website. 
- Finish existing tutorials: - EEG/Epilepsy: Rewrite scripts + update contents (with Geneva2015 walkthrough)
- Dipoles
- Group MEM/Epilepsy + Epilepsy tutorials
 
- New tutorials: - MEG steady-state / high-gamma visual
- Intra-cranial recordings
- MEG connectome (impossible without the head shapes)
- Scrambled faces (SPM/MNE-Python)
- Coherence (cortico-muscular ?)
- Co-register MEG runs (Beth)
 
- Missing in the introduction tutorials: - Volume scouts
- Sources: Model evaluation (by simulating recordings)
- Time-frequency: Description of "log freq scale" option
- Modify a structure manually: Export to Matlab/Import from Matlab
- File manipulation: file_short, file_fullpath, in_bst_*...
- Description of all fields in MRI and surfaces
 
- Script tutorials: ask what folder contains the tutorial datasets
- Missing in tutorial "Export to SPM": Add section "Compare with Brainstorm"
- Missing in page "Cite Brainstorm": Add all the methods used in the software
Current bugs
- Screen capture: - Bug on Win8/Win10: doesn't capture the correct part of the screen
- Window managers with fading effect: captures the top window
 
- Image viewer: - Difficult to get to 100%
- Buggy on some systems
 
- 2DLayout: - (TF) Images are too far apart with EEG 20 channels
- (time series) Sometimes the lines are not visible
- (time series) Does not work when DC offset is not removed
 
- Progress bar: - Doesn't close properly on some Linux systems
- Focus requests change workspace when processing constantly (Linux systems)
 
- MacOS bugs: - Buttons {Yes,No,Cancel} listed backwards
- Record tab: Text of epoch number is too big
- Colormap menus: Do not work well on compiled MacOSX 10.9.5 and 10.10
 
- Matlab bugs: - Interface looks small on screens with very high resolutions: Reduce the resolution
- Out of memory errors on Win 32bits (restart Matlab)
- Matlab 2014b bug with rmdir/movefile: Enter but never returns from the call
 
- Event markers are not visible anymore with the sequence: Open MEG, open EOG, close MEG
- in_bst_data_multi: If trials have different sizes, output is random (the one of the first file)
- Edit scout in MRI: small modifications cause huge increase of the scout size
- Canolty maps computation: Fix progress bar
- Change of default anatomy does not reset the interpolation matrices in all the subjects. - After projecting sources once from subject to default anat, the interpolation is saved and not updated. Interpolations need to be removed manually before projecting again on a new template.
 
Geeky programming details
- Hide Java panels instead of deleting them
- Interpolations: Use scatteredInterpolant, griddedInterpolant, triangulation.nearestNeighbor (2014b)
- bst_warp and channel_project: Use tess_parametrize_new instead of tess_parametrize
- Shared kernels: "get bad channels" operation in a different way (reading all the files is too slow)
- Optimize bst_get: - Now study and subject have necessarily the same folder name
- Replace big switch with separate functions
 
- Progress bar: - Add different levels (to handle sub-processes)
- Make work correctly with RAW on resting tutorial
- Uniformize calls in bst_process/Run
- Add a "Cancel" button
 
- Fix all the 'todo' blocks in the code
- Replace handle "0" with bst_get('groot')
- At the end of bst_startup in compiled mode, replace loop with waitfor(jFrame)
- Error message: Add a link to report directly the bug on the forum
- Optimize MRI viewer with patch() instead of image()
