| Line 39: | Line 39: | 
| * Show easily the maximum value at the current time point | |
| Line 41: | Line 40: | 
| * Faster display: Downsample time series before plotting | |
| Line 58: | Line 58: | 
| * Contact sheets & movies: use average of time windows instead of single instants, for each picture. | |
| Line 60: | Line 61: | 
|  * Thresholding the connectivity matrices * Stat tests on connectivity measures  | 
* Thresholding and stat tests the connectivity matrices | 
| Line 98: | Line 98: | 
|  * Hui-Ling's PAC: * https://bsp.hackpad.com/Cross-Frequency-Coupling-cChe95lhDHz * https://github.com/NCTU-BSP/MEEG  | 
|
| Line 107: | Line 110: | 
| * Explore Matlab-Python bridge: https://mail.python.org/pipermail/neuroimaging/2016-June/001001.html | * Explore Matlab-Python bridge:<<BR>> https://mail.python.org/pipermail/neuroimaging/2016-June/001001.html | 
| Line 109: | Line 112: | 
|  * Pipeline editor: * Optimize speed: Opening the window and the showing menu "Add process" are slow * Add loops over subjects/conditions/trial groups  | 
|
| Line 116: | Line 122: | 
| * Optimize pipeline editor speed: Opening the window and the showing menu "Add process" are slow | |
| Line 131: | Line 136: | 
| * Use Matlab Coder to optimize some processes: Wavelets, bandpass filter, sinusoid removal | |
| Line 136: | Line 140: | 
| * Mark with an event the possible edge effects | |
| Line 148: | Line 153: | 
| * Band-limited power envelope | * Use Matlab Coder to optimize some processes: Wavelets, bandpass filter, sinusoid removal | 
| Line 151: | Line 156: | 
|  * Pipeline editor: * Add loops over subjects/conditions/trial groups  | 
* Click on link reopens exactly the figure | 
| Line 175: | Line 179: | 
| * Resample continuous files | |
| Line 180: | Line 183: | 
|   * Significance test (Dimitrios, Leo) * Spatial smoothing: check / document parameters * Contact sheets & movies: use average of time windows instead of single instants, for each picture. * Optical flow  | 
|
| Line 191: | Line 190: | 
| * Sort files by comment | * Add buttons to sort files: by name, by comment, by date | 
What's next
A roadmap to the future developments of Brainstorm.
Contents
Current topics
Source modeling
- Implementation of a new unified minimum norm/beamformer framework (work in progress)
 
Documentation
- Standard workflows for different types of data and experiments (work in progress)
 Cross-validation with MNE and FieldTrip:
http://martinos.org/mne/dev/auto_tutorials/plot_brainstorm_auditory.html
Functional connectivity
- Significance thresholding of the connectivity matrices (not started)
 
Computation
- Removing the dependence to the Java interface to run in headless mode (not started)
 
 
Recordings
- 2D topographies: 
- Nicer topographies with circle around 2DDisc (similar to EEGLAB plots)
 Standardized plots (using FieldTrip .lay files?)
- Aligned on the midline at least
 - Contour lines sometimes messed up with Elekta recordings
 - Make the surface on which the values are interpolated simpler
 
 - MEG/EEG registration: Apply the same transformation to multiple runs
 - Montages: 
- Separators (" : MLC11" already works, could be just " : "), should add an empty space.
 
 - 2DLayout: 
- Use the same standard positions, too much space between sensors (Recordings + TF)
 - Overlay multiple conditions
 RAW files: Doesn't work when changing page => need refresh of GlobalData.Preferences.TopoLayoutOptions.TimeWindow
- Same shortcuts as the raw file viewer (right-click + move for gain)
 - Add support for montages
 
 - RAW file viewer: 
- Pre-load next page of recordings
 - Faster display: Downsample time series before plotting
 - Events: Change the category of a selected event easily, instead of deleting/marking new
 - Events: advanced process for recombining.
 Example: http://www.erpinfo.org/erplab/erplab-documentation/manual/Binlister.html
 
Interface
- Start Brainstorm without Java (-nodesktop)
 Allow FieldTrip functions in compiled version
Generalize the use of the units (field .DisplayUnits): Rewrite processes to save the units correctly
- Colormaps: 
- Allow brightness/contrast manipulations on the custom colormaps
 - Create a colormap similar to MNE, where extrema are bright
 - Global colormap max: Should get the maximum across all the open files
 
 - Open new figures as tab (docked in the Figures window)
 - Copy figures to clipboard (with the screencapture function)
 - Removing all the CTRL and SHIFT in the keyboard shortcuts
 - Display warning before opening files that are too big
 - Smooth display from figure_image (ERPimage, raster plot...)
 Contact sheets & movies: use average of time windows instead of single instants, for each picture.
Connectivity
- Thresholding and stat tests the connectivity matrices
 - Connectivity on unconstrained sources: how to group the three orientations?
 Review by Jan-Mathijs: http://journal.frontiersin.org/article/10.3389/fnsys.2015.00175/full
- Connectivity based on band limited power (Sylvain): 
- Compute Hilbert/Bandpass + correlation of the envelopes
 - Bandpass envelopes before computing correlations?
 - Compute Hilbert(sensors) and then project to source space?
 
 - Graph view: 
- Does not display negative values correctly (correlation or difference of coherence)
 - Re-write using pure Matlab code and smoothed graphics
 - Fixed scales for intensity sliders
 - Text bigger
 - Too much data in appdata
 - Fixed scales for intensity sliders
 - Add "=" shortcut for having graphs with similar configurations
 - Disable zoom in one region (serious bugs)
 - NxN on sensors: does not place the sensors correctly in space
 
 - Coherence: 
- Average cross-spectra instead of concatenating epochs (to avoid discontinuities)
 
 - Granger: 
- Crashes sometimes: improve stability
 - Re-write and optimize code
 - Add progress bar
 
 - PLV: 
- Add p-values
 - Remove evoked
 - Optimize code
 - Add time integration
 - Unconstrained sources
 
 - PAC: 
- Add input TF , to disconnect TF decomposition and PAC computation (Peter)
 - Refine frequency vector of low frequencies
 - How many central frequencies to use in bst_pac?
 - Change filters: no chirplet functions
 - bst_freqfilter: Use nfcomponents like in bst_pac
 - Esther recommended a larger frequency binning of the PAC estimation
 - PAC maps: Display all sensors at once (like TF and DynamicPAC)
 
 - Hui-Ling's PAC:
 - Time-resolved correlation/coherence: Display as time bands
 - Other metrics: 
- Coherence by bands: bst_coherence_band_welch.m
 - Granger by bands: bst_granger_band.m
 - Inter-trial coherence
 
 Tutorial coherence [1xN] : Reproduce FieldTrip results?
Connect NxN: Display as time series > Display warning before trying to open too many signals
Processes
Explore Matlab-Python bridge:
https://mail.python.org/pipermail/neuroimaging/2016-June/001001.html- Allow processes in Python and Java
 - Pipeline editor: 
- Optimize speed: Opening the window and the showing menu "Add process" are slow
 - Add loops over subjects/conditions/trial groups
 
 - PLS: 
- meg-pls dot weebly dot com
 Krishnan 2011: http://www.ncbi.nlm.nih.gov/pubmed/20656037
Cheung 2015: http://www.sciencedirect.com/science/article/pii/S1053811915007648
McIntosh 2012: http://www.ncbi.nlm.nih.gov/pubmed/22804773
McIntosh 2004: http://www.ncbi.nlm.nih.gov/pubmed/15501095
 - ICA: 
- Exploration: Add window with spectral decomposition (useful for muscle artifacts)
 - Export IC time series (and then compute their spectrum): solves the problem above
 Comparison JADE/Infomax:
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0030135- Add methods: SOBI, Fastica, AMICA/CUDICA (recommended by S Makeig)
 Dimension reduction with PCA adds artifacts: Not done by default in EEGLAB
Contact: Stephen Shall Jones ( shall-jones@infoscience.otago.ac.nz )
Student Carl Leichter detailed this in his thesis- S Makeig: Use ICA to select the IC of interest instead of only removing artifacts
 - Display of spectrum for components (PSD/FFT)
 - Use FastICA (algo crashing)
 - Understand why EEG/Epilepsy tutorial data crashes if we don't limit the number of components
 - Add components preselection: Correlation with EOG/ECG
 - Import ICA matrices available in EEGLAB .set files
 EEGLAB recommends ICA + trial rejection + ICA again: Impossible right now with Brainstorm
(http://sccn.ucsd.edu/wiki/Chapter_09:_Decomposing_Data_Using_ICA)
 - SSP: 
Display warning if changing the ChannelFlag while there is a Projector applied
Show where the attenuation is projected:
(sum(IK,2)-sum(SSP(k,:)*IK,2)./sum(IK,2)
 - Bandpass: 
- Mark with an event the possible edge effects
 - Offer option: bst_bandpass_fft / bst_bandpass_filter
 - Rewrite without the forced low-pass filter at Fs/3
 - Show warning when using inappropriate high-pass filter (precision too high)
 - Use FIR filter
 
 - Spectral flattening (John): 
- ARIMA(5,0,1): Apply on the signal before any frequency/connectivity/PAC analysis
 
 - PSD: 
- Rewrite to have the same input as coherence (frequency resolution instead of window length)
 - Use the progress bar
 
 Remove line noise: http://www.nitrc.org/projects/cleanline
- Use Matlab Coder to optimize some processes: Wavelets, bandpass filter, sinusoid removal
 - Reports: 
- Save as HTML / PDF
 - Click on link reopens exactly the figure
 
 - Time-frequency: 
- Multi-tapers
 Short-time Fourier transform: http://www.mikexcohen.com/lectures.html
Matching pursuit: http://m.jneurosci.org/content/36/12/3399.abstract?etoc
- Bug: Display logs as negative
 - Bug: 3D figures: Colormaps with "log" option doesn't work
 - Bug: Difference of power displayed in log: problems (Soheila)
 - 2D Layout in spectrum
 - Make much faster and more memory efficient (C functions coded by Matti ?)
 - TF scouts: should display average of TF maps
 - Impossible to keep complex values for unconstrained sources
 - Pad short epochs with zero values for getting lower frequencies
 - Hilbert with time bands very slow on very long files (eg. 3600s at 1000Hz) because the time vector is still full (10^7 values): save compressed time vector instead.
 - Extend clusters tab to display of TF to overlay TF signals (Svet)
 - When normalizing with baseline: Propagate with the edge effects marked in TFmask
 
 - Artifact detection: 
- Artifact rejection like SPM: if bad in 20%, bad everywhere
 - Test difference between adjacent samples
 
 - Co-registration of MEG runs: 
- SSP: Group projectors coming from different files
 - Finish validation of the method
 - Apply to continuous recordings for correcting head movements
 
 - Other processes: 
- Moving average
 - Max
 - Median
 
 - Simulation: 
Fix units in simulation processes => no *1e-9 in "simulate recordings"
- Use "add noise" process from Hui-Ling (in Work/Dev/Divers)
 
 - Use field process field "Group" to separate Input/Processing/Output options
 - Use new Matlab functions: movmean, movsum, movmedian, movmax, movmin, movvar, movstd
 
Database
- Add buttons to sort files: by name, by comment, by date
 - MEG protocols: More flexible organization of the database; sub-conditions to allow different runs X different conditions.
 - Matrix files: Allow to be dependent from other files
 - Add notes in the folders (text files, visible as nodes in the tree)
 - Screen captures: save straight to the database
 - Rename multiple files
 - Default headmodel lost when reloaded: Keep selection on the hard drive (in brainstormstudy.mat)
 
Distributed computing
Options from FieldTrip:
Loose collection of computers: https://github.com/fieldtrip/fieldtrip/tree/master/peer
Alternative, with less limitations: http://research.cs.wisc.edu/htcondor/
Single multicore machine: https://github.com/fieldtrip/fieldtrip/tree/master/engine
Batch system: https://github.com/fieldtrip/fieldtrip/tree/master/qsub
Documentation: http://fieldtrip.fcdonders.nl/faq#distributed_computing_with_fieldtrip_and_matlab
Various initiatives: http://samirdas.github.io/Data_sharing.html#/
Source modeling
- Mixed head models: 
- Project to templates (scouts or source maps)
 Create scout form maximum doesn't work (menu Sources > Max value)
- Display in MRI doesn't work
 - Smooth display: do not smooth subcortical structures
 - Export as .nii volume: doesn't work
 
 - Project individual volume grids on a template
 - Dipoles: 
- panel_dipoles: Doesn't work with multiple figures
 
 - Panel Get coordinates: Add button "find maximum"
 - Stenroos 2014 paper: Include the following methods 
Inner and outer skull surfaces generator from FieldTrip (needs SPM)
- Nolte corrected-sphere model (good model re:Alex)
 - Fast BEM models
 
 - Visualize Beamformer results: 
- Read CTF SAM .svl
 - Display as layers in the MRI viewer
 
 - Unconstrained sources: 
- Stat and connectivity: what to do? (re-send email John+Sylvain)
 
 - Overlapping spheres: improve the estimation of the spheres for the frontal lobes
 - Volume grid: 
- Test volume sources with all the subsequent processes (timefreq, stat...)
 - Optimize: 3D display (better than 9x9 cubes)
 - Optimize: vol_dilate (with 26 neighbors)
 
 - Magnetic extrapolation: Do the same thing with EEG
 - Noise covariance matrix: 
- Display with figure_image()
 - Storage of multiple noise covariance matrices (just like the head models)
 - Always save as full, then at inversion time, we can decide between full, heteroskedastic (diagonal) or homoskedastic (i.i.d, scalar)
 Problem of having inividual trials + averages in the condition => Display warning or not?
- Save nAvg in noisecov file, to make it easier to scale to other recordings
 
 Sources on surface: Display peak regions over time (time = color) => A.Gramfort
Calculate ImagingKernel * Gain for a scout
Beamformers from FieldTrip (LCMV, SAM)
- Time-frequency beamformers: 
- Band-pass everything in different frequency bands + Source estimation + TF
 - Ask data to Sarang where he sees effects that cannot be extracted with MN followed by TF
 
 - Process "Extract scouts time series": Add PCA option (replace isnorm with choice PCA/Norm)
 - BEM: Fix unstable results when one vertex is too close from the layers (5mm ?)
 - Hui-Ling beamformers: 
- More explanations about what is in NAI and Spatial filters
 Explain that is this is better to study effects extended in time (Ntime > Nsensors)
- Group LCMV+MCB
 - Condition LEFT median nerve: very bad results
 
 Menu Sources > Simulate recordings:
- Do not close the 3D figures after generating a new file
 - Add a process equivalent to this menu
 
Anatomy
MNI coordinates: Extend to non FreeSurfer volumes (BrainSuite volumes that are not 256x256x256)
- Project all sub-cortical structures to default anatomy (check code from Denis S)
 BrainVISA: Add support for MarsAtlas (Guillaume A)
- Add cerebellum to default model generated with "Import FS anatomy"
 - Import MRIs with different resolutions: re-interpolate automatically
 - Edit fiducials: Replace 6 text boxes with 1 for easy copy-paste (see fiducials.m)
 - Warping: Scale option has to be fixed, it is currently very unstable
 - Scouts: 
- Display edges in the middle of the faces instead of the vertices
 - Display scouts in a tree: hemisphere, region, subregion
 - Downsample to atlas: allow on timefreq/connect files
 - Sort scouts by region in process options
 
 Menu head model > Copy to other conditions/subjects (check if applicable first)
- Generate mixed density surfaces
 - Optimize computation interpolation MRI-surface (tess_tri_interp)
 - Render surface envelope in the MRI as a thin line instead of the full interpolation matrix
 - Major bug when importing surfaces for an MRI that was re-oriented manually
 - Smooth surface: Fix little spikes due to irregularities in the mesh
 - Add eyes models to attract eye activity
 - tess_mrimask: Not robust enough to major holes in the brain
 
ECOG/SEEG
- Co-register MRI and CT for electrodes marking in the MRI Viewer
 - Import/export electrodes positions in MNI/SCS/MRI coordinates
 - Display SEEG+ECOG contacts at the same time
 Problem of difference between RAS and TkRegRAS: http://neuroimage.usc.edu/forums/showthread.php?1958-SEEG-electrodes-and-subject-s-anatomy-are-not-alligned
Statistics
- ANOVA: 
- Use LENA functions(?)
 - Output = 1 file per effect, all grouped in a node "ANOVA"
 - Display several ANOVA maps (from several files) on one single figure, using a "graphic accumulator", towards which one can send any type of graphic object
 
 - New process to test for Gaussianity using swtest
 - PLS: Partial Least Squares
 - Simulate recordings with specific properties, for stat validation
 Quality control before statistics, on condition averages across subjects:
mean(baseline)/std(baseline): shows bad subject quickly.Use SurfStat: Impements interesting things, like an analytical cluster-based p-value correction (Random-field theory which is used in SPM) - Peter
Input / output
- 4D file format: 
- Reference gradiometers: Keep the orientation of the first or second coil?
 - Reference gradiometers: Add the sensor definition from coil_def.dat
 - Validate with phatom recordings that noise compensation is properly taken into account
 - References at too far from the head sensors in Marseille 4D system
 - The noise compensation is considered to be always applied on the recordings, not sure this assumption is always correct
 
 - EEG File formats: 
EEG CeeGraph
- EGI: Finish support for epoched files (formats 3,5,7)
 
 - BCI2000 Input (via EEGLAB plugin)
 - EEGLAB import: 
- Support for binary AND epoched files (now it's one or the other)
 - Allow epoched files with recordings saved in external files
 
 - BST-BIN: Add compression
 - Review raw on all the file formats (ASCII EEG and Cartool missing)
 - gTec EEG recordings: Read directly from the HDF5 files instead of the Matlab exports.
 - Use new Matlab functions readtable/writetable (2006b): for Excel and text files
 
Distribution & documentation
Workflows FieldTrip: http://www.fieldtriptoolbox.org/faq/what_types_of_datasets_and_their_respective_analyses_are_used_on_fieldtrip
Reference tutorials on Google scholar + ResearchGate
- Cleaning threads on the forum
 - Update the list of features and link in the Introduction page
 - Finish existing tutorials: 
- EEG/Epilepsy: Rewrite scripts + update contents (with Geneva2015 walkthrough)
 - Dipoles
 - Group MEM/Epilepsy + Epilepsy tutorials
 
 - New tutorials: 
- MEG steady-state / high-gamma visual
 - Intra-cranial recordings
 - MEG connectome (impossible without the head shapes)
 - Coherence (cortico-muscular ?)
 - Co-register MEG runs (Beth)
 
 - Missing in the introduction tutorials: 
SSP: Create projector from any topography figure (right-click > Create SSP)
- Volume scouts
 - Time-frequency: Description of "log freq scale" option
 - Scripting: Modify a structure manually: Export to Matlab/Import from Matlab
 - Scripting: File manipulation: file_short, file_fullpath, in_bst_*...
 - Detect bad channels: Peak-to-peak
 
 - Script tutorials: ask what folder contains the tutorial datasets
 - Missing in tutorial "Export to SPM": Add section "Compare with Brainstorm"
 - Missing in page "Cite Brainstorm": Add all the methods used in the software
 
Current bugs
- Screen capture: 
- Bug on Win8/Win10: doesn't capture the correct part of the screen
 - Window managers with fading effect: captures the top window
 
 - Image viewer: 
- Difficult to get to 100%
 - Buggy on some systems
 
 - 2DLayout: 
- (TF) Images are too far apart with EEG 20 channels
 - (TF) Units are weird with % values
 - (TF) Difficult to navigate in frequencies: Scaling+changing frequency resets the scaling
 - (time series) Sometimes the lines are not visible
 - (time series) Does not work when DC offset is not removed
 
 - Progress bar: 
- Doesn't close properly on some Linux systems
 - Focus requests change workspace when processing constantly (Linux systems)
 
 - MacOS bugs: 
- Buttons {Yes,No,Cancel} listed backwards
 - Record tab: Text of epoch number is too big
 - Colormap menus: Do not work well on compiled MacOSX 10.9.5 and 10.10
 
 - Matlab bugs: 
- Interface looks small on screens with very high resolutions: Reduce the resolution
 
 - Event markers are not visible anymore with the sequence: Open MEG, open EOG, close MEG
 - in_bst_data_multi: If trials have different sizes, output is random (the one of the first file)
 - Edit scout in MRI: small modifications cause huge increase of the scout size
 - Canolty maps computation: Fix progress bar
 - Change of default anatomy does not reset the interpolation matrices in all the subjects. 
- After projecting sources once from subject to default anat, the interpolation is saved and not updated. Interpolations need to be removed manually before projecting again on a new template.
 
 
Geeky programming details
- Hide Java panels instead of deleting them
 - Interpolations: Use scatteredInterpolant, griddedInterpolant, triangulation.nearestNeighbor (2014b)
 - bst_warp and channel_project: Use tess_parametrize_new instead of tess_parametrize
 - Shared kernels: "get bad channels" operation in a different way (reading all the files is too slow)
 - Optimize bst_get: 
- Now study and subject have necessarily the same folder name
 - Replace big switch with separate functions
 
 - Progress bar: 
- Add different levels (to handle sub-processes)
 - Make work correctly with RAW on resting tutorial
 - Uniformize calls in bst_process/Run
 - Add a "Cancel" button
 
 - Fix all the 'todo' blocks in the code
 - Error message: Add a link to report directly the bug on the forum
 