11063
Comment:
|
18002
|
Deletions are marked like this. | Additions are marked like this. |
Line 4: | Line 4: |
== Next six months == ==== Data acquisition ==== * Improve the acquisition of the head points and the registration MEG / MRI ==== Pre-processing ==== * Extend processing of continuous CTF files to all file formats * Improve detection and correction of artifacts with SSP * Co-registration of several MEG runs on one single head position * Make all the main operations available in the pipeline editor ==== File formats ==== * MRI: MINC * EEG: Stellate * EEG: Brain Products / !BrainAmp * CTF SAM Beamformer results ==== Functionnal connectivity ==== * Implementation of methods developed at USC <<BR>><<BR>><<BR>> |
== Current topics == ==== Documentation ==== * Merging the 12+3 introduction tutorials to illustrate better the latest developments ==== Source modeling ==== * Implementation of a new unified minimum norm/beamformer framework ==== Functional connectivity ==== * Significance thresholding of the connectivity matrices ==== Computation ==== * Removing the dependence to the Java interface to run in headless mode * Interacting directly with distributed computing systems ==== Compatibility ==== * Reading and writing FieldTrip structures * Calling FieldTrip functions from the pipeline <<BR>><<BR>> |
Line 26: | Line 25: |
* Nicer 2D topographies, standardized (using FieldTrip .lay files?) * 2DLayout (recordings + TF): Use the same standard positions, too much space between sensors |
|
Line 27: | Line 28: |
* Adding events using configurable shortcuts (CTRL+number) * If "Use SSP " option is selected, automatically select "Remove baseline" and "CTF compensations" |
* Pre-load next page of recordings |
Line 30: | Line 30: |
* 2DLayout: Doesn't work when changing page => need refresh of GlobalData.Preferences.TopoLayoutOptions.TimeWindow * EEG reference/storage: * Intracranial electrodes: Define in the MRI viewer * Bad channels that can be specified at the program level (for sites that have permanently bad channels) => AS Dubarry |
|
Line 31: | Line 35: |
* Process correctly CTF files saved without the 3rd order grad correction (apply correction before) * Allow to overwrite RAW files (but with a HUGE warning) * Update file definition + events if time changes (ex: resample) * Make it work for all the file formats * Homogenize a selection of several subjects/conditions * Popup menu when more than one study selected * Creation of a common channel file (match channels by names, not by order) * Register MEG runs (recompute fields for a different set of sensors, MEGCoregister from old brainstorm) * bst_selections: * Add user defined combinations of sensors (eg. "double banana" for EEG) * Use this to produce "inversed polarity" displayes too (useful in EEG) * Standard setups for all the EEG caps * Intracranial electrodes: * Display in the MRI viewer * Different data type * Display time series * Images of amplitude: [sensor x time], [trial x time], scout: [trial x time] (similaire to erpimage in eeglab) |
* Make it work for all the file formats (at least bandpass filter + sin removal) * Events: advanced process for recombining. Example: http://www.erpinfo.org/erplab/erplab-documentation/manual/Binlister.html * Colormaps: * Create a colormap similar to MNE, where extrema are bright * NIRS: * Add new data type * Display of sensors by pairs oxy/deoxy (red/blue), overlaid * Images of amplitude: [sensor x time], [trial x time], scout: [trial x time] * Can be done with Matrix > View as image: extract cluster, concatenate for all trials * 2D Layout for multiple conditions * Filtering: Use short FIR filters instead of IIR for bandpass, to limit the ringing<<BR>>Or allow the users to edit the LowStop parameter in bst_bandpass. * Show easily recordings maximum/values in the file viewer * Copy figures to clipboard (with the screencapture function) == Interface == * Global colormap max: Should get the maximum across all the open files * Open new windows as tab == Connectivity == * Thresholding the connectivity matrices * t-tests on connectivity measures * Graph view: * Does not work on Matlab 2015a * Fixed scales for intensity sliders * Fix zoom in one region * Text bigger * Too much data in appdata * Coherence: * Average cross-spectrum instead of concatenating epochs (to avoid discontinuities) * Other metrics: * Coherence by bands: bst_coherence_band_welch.m * Granger by bands: bst_granger_band.m * Inter-trial coherence * Work on progress bars * Tutorial coherence [1xN] |
Line 50: | Line 73: |
* Distributed processing: Brainstorm that can run without Java * Use Matlab Coder to optimize some processes: Wavelets, bandpass filter, sinusoid removal * Allow processes in Python and Java * Call FieldTrip functions from pipeline editor * Optimize opening time ofr for the menu "Add process" |
|
Line 51: | Line 79: |
* Make SSP projections dynamic, and keep the full list instead of always them combining them * Take the bad channels in account in the application of the SSP * Refresh display after changing the list of bad channels (imported files + raw) so the SSP are applied correctly * When processing multiple files: waitbar is all messed up * Tune parameters for the automatic detection of heartbeats and eye blinks * Write documentation * Complete processing pipeline: * Import + pre-process * Sources / head model / noise covariance * Project sources * Do not generate errors, stay silent and generate a report log that is shown at the end * Command-line Brainstorm: for working on clusters (make sure that there are no interface interruptions) |
* Make average the default option * Display warning if changing the ChannelFlag while there is a Projector applied * Show where the attenuation is projected:<<BR>>(sum(IK,2)-sum(SSP(k,:)*IK,2)./sum(IK,2) * Bandpass: <<BR>> * Offer option: bst_bandpass_fft / bst_bandpass_filter * Rewrite without the force low-pass filter at Fs/3 * Show warning when using inappropriate high-pass filter (precision too high) * Use FIR filter * Spectral flattening (John): * Apply on the signal before any frequency/connectivity/PAC analysis * Using ARIMA(5,0,1) * Example code:<<BR>><<BR>> {{{ arm = mean(lpc(diff(detrend(Fbase')),5)); % detrend and diff PRE = filter(arm,1,diff(detrend(Fbase')))'; % apply to the data| X = filter(arm,1,diff(detrend(F')))'; X(:,1:length(arm)) = []; Time = tndx((length(arm)+2):end)/1000 - SOT; }}} * PSD: * Rewrite to have the same input as coherence * Normalize with the total power (TF/sum(TF,3)) * Remove line noise: http://www.nitrc.org/projects/cleanline * Interpolate the bad channels * ICA for cleaning eye movements in EEG low density (SSP don't work well) * Band-limited power envelope * Reports: * Save as HTML / PDF * Do not display the intermediate files * Pipeline editor: * Add loops over subjects/conditions/trial groups * Time-frequency: * Standardize using: diff before calculation + cumsum (checkbox "flatten data") * Frequency bands: extended syntax (ex: [2 3 4], 10:5:90, ...) * Display logs as negative * 2D Layout in spectrum * Make much faster and more memory efficient (C functions coded by Matti ?) * TF scouts: should display average of TF maps * Artifact detection: * Detection of bad segments in the RAW files (Beth) * Artifact rejection like SPM: if bad in 20%, bad everywhere * Test difference between adjacent samples |
Line 65: | Line 125: |
* By subject AND condition * Time-frequency: * Write script for timefreq tutorial * Make much faster and more memory efficient (C functions coded by Matti ?) * Power spectrum: computation (FFT/welch, or average of TF) + display(f/Power, 2DLayout) * Display stat computed on time-frequency data * Display TF maps separately for the two gradiometers (if not: overlap) * Source reconstruction by frequency bands * Scouts on surface / time-freq * Process selection interface: * Do not reload the list a each display, but once when starting Brainstorm * Popup menus: Add a "Process" menu with all the available processes * Bug when redimensioning window (with more than one process) * isAvgRef: warning quand process necessite des donnees en AVG REF en entree * Save "freqband" option when edited from custom processes * Other processes: |
* Save standard deviation * Display standard deviation as a halo around the time series * Co-registration of MEG runs: * SSP: Group projectors coming from different files * Finish validation of the method * Apply to continuous recordings for correcting head movements * Resample continuous files * Current Source Density (CSD) => Ghislaine<<BR>>http://psychophysiology.cpmc.columbia.edu/software/CSDtoolbox/index.html * Other processes:<<BR>> |
Line 83: | Line 135: |
* Remove linear trend * Power line removal * Bug: gradnorm crashes with bad channels |
* Max * Median * Significance test (Dimitrios, Leo) |
Line 87: | Line 139: |
* Sinusoid removal: fix new function | |
Line 89: | Line 140: |
* Optical flow * Simulation: * Fix units in simulation processes => no *1e-9 in "simulate recordings" * Use "add noise" process from Hui-Ling (in Work/Dev/Divers) |
|
Line 91: | Line 146: |
* Optimize startup speed * Start Brainstorm without Java (-nodesktop) * Sort files by comment |
|
Line 92: | Line 150: |
* GUI: Save configuration of windows (per protocol) | * Group matrix files => allow to process matrix files by trial types |
Line 96: | Line 154: |
* Screen captures: save straight to the database * Rename multiple files * Allow matrix files to be attached to other files == Distributed computing == * Options from FieldTrip: * Loose collection of computers: https://github.com/fieldtrip/fieldtrip/tree/master/peer * Alternative, with less limitations: http://research.cs.wisc.edu/htcondor/ * Single multicore machine: https://github.com/fieldtrip/fieldtrip/tree/master/engine * Batch system: https://github.com/fieldtrip/fieldtrip/tree/master/qsub * Documentation: http://fieldtrip.fcdonders.nl/faq#distributed_computing_with_fieldtrip_and_matlab * PSOM: http://psom.simexp-lab.org/ |
|
Line 97: | Line 170: |
* Visualize Beamformer results (contact Zainab Fatima): | * Dipoles: * Finish dipole scanning (allow the tab to control multiple figures separately) * Dipole fitting: We will not implement non-linear fits, recommended use of dense volume grids * panel_dipoles: Doesn't work with multiple figures * Read easily dipole coordinates: Click on one selects it and open the panel Get coordinates * Panel Get coordinates: Add button "find maximum" * Create scout form maximum: Not available yet for mixed/volume head model. * Stenroos 2014 paper: Include the following methods * Inner and outer skull surfaces generator from FieldTrip (needs SPM, probably not so different from BST) * Nolte corrected-sphere model (good model re:Alex) * Fast BEM models * Visualize Beamformer results: |
Line 99: | Line 183: |
* Create new file type in the database | |
Line 103: | Line 186: |
* Define as default * Check all the processes |
|
Line 106: | Line 187: |
* Stat and connectivity: what to do? (re-send email John+Sylvain) | |
Line 110: | Line 192: |
* Optimize: 3D display (better that 9x9 cubes) | * Optimize: 3D display (better than 9x9 cubes) |
Line 112: | Line 194: |
* Optimize: grid_interp_mri * Magnetic extrapolation: * Do the same thing with EEG * Optimize bst_extrapm.m, add waitbar * Use the noise covariance from the database instead of recomputing it * Project sources: * Adapt smooth factor to the number of vertices * Number of neighbors to consider = average number of neighbors in the target mesh. * Compute by small time blocks |
* Magnetic extrapolation: Do the same thing with EEG |
Line 122: | Line 196: |
* Display with figure_image() * Storage of multiple noise covariance matrices (just like the head models) * Always save as full, then at inversion time, we can decide between full, heteroskedastic (diagonal) or homoskedastic (i.i.d, scalar) * Problem of having inividual trials + averages in the condition => Display warning or not? |
|
Line 123: | Line 201: |
* When deploying to other conditions: Apply destination SSP (!NoiseCov = SSP . !NoiseCov . SSP' ) | * When deploying to other conditions: Apply destination SSP (NoiseCov = SSP . NoiseCov . SSP' ) |
Line 126: | Line 204: |
* Calculate ImagingKernel * Gain for a scout * EEG Source modeling: Manage references and bipolar montages properly (maybe not necessary) * MEG source modeling: Do reconstruction only for a subset of sensors for estimating dipoles? * Processes compute head model and sources: Additional option to set the file comment * Time-frequency beamformers: * Band-pass everything in different frequency bands + Source estimation + TF * Ask data to Sarang where he sees effects that cannot be extracted with MN followed by TF * Display volume scouts and surface scouts at the same time * Process "Extract scouts time series": Add PCA option (replace isnorm with choice PCA/Norm) * BEM: Fix unstable results when one vertex is too close from the layers (5mm ?) |
|
Line 128: | Line 216: |
* BEM surfaces: * Fix the bumps at the back of the head * Surface edges: same color as the surface when color was changed |
* Project all sub-cortical structures to default anatomy * Warping: Scale option has to be fixed, it is currently very unstable * Scouts: * Display edges in the middle of the faces instead of the vertices * Project scouts betweens subjects and between hemispheres * Display scouts in a tree: hemisphere, region, subregion * Downsample to atlas: allow on timefreq/connect files * Sort scouts by region in process options * Co-register MRI and CT for electrodes marking in the MRI Viewer * Generate mixed density surfaces |
Line 132: | Line 227: |
* Improve ICP registration headpoints / scalp (chanfrein, multi-resolution, see with C Grova...) * Auto-reorientation of MRI after selected NAS / LPA / RPA |
|
Line 135: | Line 228: |
* ICBM brain * MINC MRI reader: EMMA, NIAK (Pierre Bellec), HDF5 directly read in Matlab * ICBM average surfaces + atlas * Using CIVET pipeline for extracting surfaces * Atlas: * Use BrainVISA / !FreeSurfer labeling automatically when importing cortex surface * Finalize Brodmann scouts * Remove NCS/Talairach coordinate system, or fix it => Sylvain, Karim ND * Clustering cortex: Dimitrios, David, Yu-Teng |
* Use mid-gray instead of pial surface? * Smooth surface: Fix little spikes to irregularities in the mesh * Menu head model > Copy to other conditions/subjects (check if applicable first) * Add cerebellum to default model generated with "Import FS anatomy" * Add eyes models to attract eye activity |
Line 146: | Line 235: |
* Stat on scouts / clusters / "matrix" | |
Line 152: | Line 240: |
* http://www.adscience.fr/uploads/ckfiles/files/html_files/StatEL/statel_wilcoxon.htm * http://www.mathworks.fr/fr/help/stats/signrank.html * Less powerful than t-tests |
|
Line 158: | Line 249: |
* t-test on volume sources * Paired t-test on unconstrained sources: (convert to flat + Z-score) => AnneSo * Question of Gaussianity of the samples: take a subset of samples + Kolmogorov-Smirnov / Shapiro-Wilk test * http://fr.wikipedia.org/wiki/Test_de_Shapiro-Wilk * http://stats.stackexchange.com/questions/362/what-is-the-difference-between-the-shapiro-wilk-test-of-normality-and-the-kolmog * http://www.mathworks.fr/fr/help/symbolic/mupad_ug/perform-shapiro-wilk-test.html * http://www.mathworks.fr/fr/help/symbolic/mupad_ref/stats-swgoft.html * http://stackoverflow.com/questions/14383115/shapiro-wilk-test-in-matlab * Create icons for Stat/PAC, Stat/Sprectrum, etc. * One sample t-test across subjects |
|
Line 160: | Line 261: |
* Finish MINC/CIVET integration (finir lecture MINC2: P Bellec) * Send email to CIVET mailing list when done * FieldTrip structures: In / Out (see fieldtrip/utilities/ft_datatype_*) |
|
Line 161: | Line 265: |
* Stellate * !BrainVision / !BrainAmp: Get functions from EEGLAB * Nihon Kohden * EDF+ * EEG !CeeGraph * NEUROFILE = COHERENCE EEG/video !LongTerm Monitoring => Manfred Spueler |
* EEG CeeGraph |
Line 168: | Line 267: |
* Other file formats * MEG160 (KIT) * CTF: Read STIM channel and generate !MarkerFile * EEGLAB: Apply ICA matrices, get number of trials for AVG files * !FieldTrip structures: In / Out * Output for all the channel file formats * Define scouts from SPM / Analyze 3D masks * Files > 2Gb: display warnings |
* BCI2000 Input (via EEGLAB plugin) * EEGLAB import: * Selection of conditions in script mode * Support for binary AND epoched files (now it's one or the other) * Allow epoched files with recordings saved in external files (now external files implies continuous recordings) * BST-BIN: Add compression * Review raw on all the file formats (ASCII EEG and Cartool missing) |
Line 178: | Line 276: |
* Version with big fonts for live demos | * Document iEEG in "What's new" * Rewrite basic 12+3 tutorials: group in one series * Illustrate 2D Layout * Illustrate unconstrained sources * Cleaning threads on the forum |
Line 180: | Line 282: |
* List of all the keyboard and mouse shortcuts * Send emails to registered users to anounce major improvements * Script tutorials: * Update them to reflect all the recent changes * Script for the time-frequency computation * Introduction tutorials: * Estimate time to complete each tutorial * Clusters * Anatomy: Segmentation with !FreeSurfer |
* Publication list: Fold by years * Finish existing tutorials: * Dipoles * Auditory: Extend to MNE/EEGLAB/SPM * Auditory: Finish scripts * Group MEM/Epilepsy + Epilepsy tutorials * New tutorials: * MEG connectome * Scrambled faces (SPM/MNE-Python) * Describe all the processes * Statistics * Coherence (cortico-muscular ?) * Intra-cranial recordings (Average ref by groups using Comment field) * Co-register MEG runs (Beth) * Missing in the introduction tutorials: * Volume scouts |
Line 190: | Line 300: |
* First steps: Temporary folder * Exploration: Clusters |
|
Line 191: | Line 303: |
* Coordinate sytems: How to convert between the different coordinates systems in scripts * Sources: Modelized data * Sources: theshold min. size (not documented yet) * Scouts: Atlases of Tzourio-Mazoyer and Brodman * Processes: Describe all the processes * Processes: How to write your own processes (user folder for processes) * Processes: Processing RAW files * Import raw recordings: Add "detect bad trials/channels" in the pipeline * Advanced tutorials: * MNE sample dataset * EEG (How to import an EEG cap) * MRI segmentation with !FreeSurfer => David Wheland * How to make and compress a movie (Brainstorm + !VirtualDub + XVid) * Display the "What's new" page after downloading new version of brainstorm * Ask users to send their channel files, align on Colin, distribute |
* Sources: Model evaluation (by simulating recordings) * Sources: Theshold min. size (not documented yet) * Time-frequency: Description of "log freq scale" option * Modify a structure manually: Export to Matlab/Import from Matlab * Missing in tutorial "Export to SPM": Add section "Compare with Brainstorm" * Missing in page "Cite Brainstorm": Add all the methods used in the software * Reference tutorials on Google scholar * Play videos on wiki with <video> tag (save videos in .ogg) == Current bugs == * Workshops: * Create scouts doesn't work: scout created on the other side of the brain * Import anatomy folder: Out of memory on Win 32bits (restart Matlab) * Compute head model: Out of memory on Win 32bits * Bandpass filter: Out of memory (Auditory workshop) * Bug workshop Michael (Mint 12/gnome3/linux 3.0.0-12, KWin/Mutter/Compiz) * Cannot import two .ds folders at once * Colors inverted in the PSD/TF plots (power vs. log) * Cannot type the name of a channel in "Detect ECG" * Image viewer: Difficult to get to 100% * Canolty maps computation: Fix progress bar * Smooth TF windows that contain multiple plots * Record tab: Text of epoch number is too big on MacOS * in_bst_data_multi: If trials have different sizes, output is random (the one of the first file) * tree_dependencies: sources files, reprojected on default anatomy; If based on data files that are bad trials, they should be ignored by tree_dependencies, and they are not * Image viewer has some bugs on some systems * Screen capture when there is a fading effect in the window manager: captures the window * Close figure with coherence results should hide the "frequency" slider * Edit scout in MRI: small modifications cause huge increase of the scout size * Reports: Text size is too small with Java 1.5 (2006b-2007a) * Optimize MRI viewer with patch() instead of image() * Matlab 2014b bug with rmdir/movefile: Enter but never returns from the call * 2DLayout (time series): * Sometimes the lines are not visible * Does not work when DC offset is not removed * 2DLayout (TF): Images are too far apart with EEG 20 channels * Colormap menus: Do not work well on compiled MacOSX 10.9.5 and 10.10 * Event markers are not visible anymore with the sequence: Open MEG, open EOG, close MEG. |
Line 208: | Line 343: |
* OpenGL options: {none, software, hardware} * Bug: Scout without overlay, adapt scale for each graph when "Uniformize" option is unchecked (mixing sources + zscores) * Waitbars: * Replace old waitbars with java ones * Add a "Cancel" button on waitbars when the bounds are defined (ie. when bst controls the process) * Double-click doesn't work well on some Linux workstations * Bug: Menu "Use default EEG cap" doesn't work for a multiple selection (setting the same EEG cap for several subjects) * Bug node selection: click on sources > TF: select node-source, not node-condition * Bug tree_dependencies: sources files, reprojected on default anatomy; If based on data files that are bad trials, they should be ignored by tree_dependencies, and they are not |
* Removing all the CTRL and SHIFT in the keyboard shortcuts * Hide Java panels instead of deleting them * mri2scs: convert arguments to meters * Interpolations: Use scatteredInterpolant, griddedInterpolant, triangulation.nearestNeighbor (Matlab 2014b) |
Line 218: | Line 348: |
* Bug in_bst_data_multi: If trials have different sizes, output is random (the one of the first file)... * sLORETA: Values are now multiplied by 1e12 at loading for display => has do to be done in another way |
|
Line 221: | Line 349: |
* Write shepards.m with new algorithm for nearest neighbors * Use Matlab Coder to compile / optimize some processes * Optimize calls to bst_get, now study and subject have necessarily the same folder name |
* Optimize bst_get: * Now study and subject have necessarily the same folder name * Replace big switch with separate functions * Progress bar: * Add different levels (to handle sub-processes) * Make work correctly with RAW on resting tutorial * Uniformize calls in bst_process/Run * Add a "Cancel" button * Line smoothing / anti-aliasing (time series figures) * Fix all the 'todo' blocks in the code * Replace handle "0" with bst_get('groot') * At the end of bst_startup in compiled mode, replace loop with waitfor(jFrame) * Error message: Add a link to report directly the bug on the forum * in_bst_results (isFull=1): DataFile should be relative |
What's next
A roadmap to the future developments of Brainstorm.
Current topics
Documentation
- Merging the 12+3 introduction tutorials to illustrate better the latest developments
Source modeling
- Implementation of a new unified minimum norm/beamformer framework
Functional connectivity
- Significance thresholding of the connectivity matrices
Computation
- Removing the dependence to the Java interface to run in headless mode
- Interacting directly with distributed computing systems
Compatibility
Reading and writing FieldTrip structures
Calling FieldTrip functions from the pipeline
Recordings
Nicer 2D topographies, standardized (using FieldTrip .lay files?)
- 2DLayout (recordings + TF): Use the same standard positions, too much space between sensors
- RAW file viewer:
- Pre-load next page of recordings
- Documentation: Add definition of bad segments
2DLayout: Doesn't work when changing page => need refresh of GlobalData.Preferences.TopoLayoutOptions.TimeWindow
- EEG reference/storage:
- Intracranial electrodes: Define in the MRI viewer
Bad channels that can be specified at the program level (for sites that have permanently bad channels) => AS Dubarry
- RAW processing:
- Make it work for all the file formats (at least bandpass filter + sin removal)
Events: advanced process for recombining. Example: http://www.erpinfo.org/erplab/erplab-documentation/manual/Binlister.html
- Colormaps:
- Create a colormap similar to MNE, where extrema are bright
- NIRS:
- Add new data type
- Display of sensors by pairs oxy/deoxy (red/blue), overlaid
- Images of amplitude: [sensor x time], [trial x time], scout: [trial x time]
Can be done with Matrix > View as image: extract cluster, concatenate for all trials
- 2D Layout for multiple conditions
Filtering: Use short FIR filters instead of IIR for bandpass, to limit the ringing
Or allow the users to edit the LowStop parameter in bst_bandpass.- Show easily recordings maximum/values in the file viewer
- Copy figures to clipboard (with the screencapture function)
Interface
- Global colormap max: Should get the maximum across all the open files
- Open new windows as tab
Connectivity
- Thresholding the connectivity matrices
- t-tests on connectivity measures
- Graph view:
- Does not work on Matlab 2015a
- Fixed scales for intensity sliders
- Fix zoom in one region
- Text bigger
- Too much data in appdata
- Coherence:
- Average cross-spectrum instead of concatenating epochs (to avoid discontinuities)
- Other metrics:
- Coherence by bands: bst_coherence_band_welch.m
- Granger by bands: bst_granger_band.m
- Inter-trial coherence
- Work on progress bars
- Tutorial coherence [1xN]
Processes
- Distributed processing: Brainstorm that can run without Java
- Use Matlab Coder to optimize some processes: Wavelets, bandpass filter, sinusoid removal
- Allow processes in Python and Java
Call FieldTrip functions from pipeline editor
- Optimize opening time ofr for the menu "Add process"
- SSP:
- Make average the default option
Display warning if changing the ChannelFlag while there is a Projector applied
Show where the attenuation is projected:
(sum(IK,2)-sum(SSP(k,:)*IK,2)./sum(IK,2)
Bandpass:
- Offer option: bst_bandpass_fft / bst_bandpass_filter
- Rewrite without the force low-pass filter at Fs/3
- Show warning when using inappropriate high-pass filter (precision too high)
- Use FIR filter
- Spectral flattening (John):
- Apply on the signal before any frequency/connectivity/PAC analysis
- Using ARIMA(5,0,1)
Example code:
arm = mean(lpc(diff(detrend(Fbase')),5)); % detrend and diff PRE = filter(arm,1,diff(detrend(Fbase')))'; % apply to the data| X = filter(arm,1,diff(detrend(F')))'; X(:,1:length(arm)) = []; Time = tndx((length(arm)+2):end)/1000 - SOT;
- PSD:
- Rewrite to have the same input as coherence
- Normalize with the total power (TF/sum(TF,3))
Remove line noise: http://www.nitrc.org/projects/cleanline
- Interpolate the bad channels
- ICA for cleaning eye movements in EEG low density (SSP don't work well)
- Band-limited power envelope
- Reports:
- Save as HTML / PDF
- Do not display the intermediate files
- Pipeline editor:
- Add loops over subjects/conditions/trial groups
- Time-frequency:
- Standardize using: diff before calculation + cumsum (checkbox "flatten data")
- Frequency bands: extended syntax (ex: [2 3 4], 10:5:90, ...)
- Display logs as negative
- 2D Layout in spectrum
- Make much faster and more memory efficient (C functions coded by Matti ?)
- TF scouts: should display average of TF maps
- Artifact detection:
- Detection of bad segments in the RAW files (Beth)
- Artifact rejection like SPM: if bad in 20%, bad everywhere
- Test difference between adjacent samples
- Average:
- Remember how many trials were used per channel
- Save standard deviation
- Display standard deviation as a halo around the time series
- Co-registration of MEG runs:
- SSP: Group projectors coming from different files
- Finish validation of the method
- Apply to continuous recordings for correcting head movements
- Resample continuous files
Current Source Density (CSD) => Ghislaine
http://psychophysiology.cpmc.columbia.edu/software/CSDtoolbox/index.htmlOther processes:
- Moving average
- Max
- Median
- Significance test (Dimitrios, Leo)
- Spatial smoothing: check / document parameters
Contact sheets & movies: use average of time windows instead of single instants, for each picture.
- Optical flow
- Simulation:
Fix units in simulation processes => no *1e-9 in "simulate recordings"
- Use "add noise" process from Hui-Ling (in Work/Dev/Divers)
Database
- Optimize startup speed
- Start Brainstorm without Java (-nodesktop)
- Sort files by comment
- MEG protocols: More flexible organization of the database; sub-conditions to allow different runs X different conditions.
Group matrix files => allow to process matrix files by trial types
- Add notes in the folders (text files, visible as nodes in the tree)
- Screen captures: save straight to the database
- Rename multiple files
- Allow matrix files to be attached to other files
Distributed computing
Options from FieldTrip:
Loose collection of computers: https://github.com/fieldtrip/fieldtrip/tree/master/peer
Alternative, with less limitations: http://research.cs.wisc.edu/htcondor/
Single multicore machine: https://github.com/fieldtrip/fieldtrip/tree/master/engine
Batch system: https://github.com/fieldtrip/fieldtrip/tree/master/qsub
Documentation: http://fieldtrip.fcdonders.nl/faq#distributed_computing_with_fieldtrip_and_matlab
Source modeling
- Dipoles:
- Finish dipole scanning (allow the tab to control multiple figures separately)
- Dipole fitting: We will not implement non-linear fits, recommended use of dense volume grids
- panel_dipoles: Doesn't work with multiple figures
- Read easily dipole coordinates: Click on one selects it and open the panel Get coordinates
- Panel Get coordinates: Add button "find maximum"
- Create scout form maximum: Not available yet for mixed/volume head model.
- Stenroos 2014 paper: Include the following methods
Inner and outer skull surfaces generator from FieldTrip (needs SPM, probably not so different from BST)
- Nolte corrected-sphere model (good model re:Alex)
- Fast BEM models
- Visualize Beamformer results:
- Read CTF SAM .svl
- Display as layers in the MRI viewer
- Unconstrained sources:
- Compute unconstrained and then project on the normal ?
- Difference and stat should be: norm(A) - norm(B)
- Stat and connectivity: what to do? (re-send email John+Sylvain)
- Overlapping spheres: improve the estimation of the spheres for the frontal lobes
- Volume grid:
- Scouts 3D
- Test volume sources with all the subsequent processes (timefreq, stat...)
- Optimize: 3D display (better than 9x9 cubes)
- Optimize: vol_dilate (with 26 neighbors)
- Magnetic extrapolation: Do the same thing with EEG
- Noise covariance matrix:
- Display with figure_image()
- Storage of multiple noise covariance matrices (just like the head models)
- Always save as full, then at inversion time, we can decide between full, heteroskedastic (diagonal) or homoskedastic (i.i.d, scalar)
Problem of having inividual trials + averages in the condition => Display warning or not?
- Save nAvg in noisecov file, to make it easier to scale to other recordings
When deploying to other conditions: Apply destination SSP (NoiseCov = SSP . NoiseCov . SSP' )
Sources on surface: Display peak regions over time (time = color) => A.Gramfort
- Simulation: synthesize pseudo data-files from a cortex patch (duration, amplitude, noise)
Calculate ImagingKernel * Gain for a scout
- EEG Source modeling: Manage references and bipolar montages properly (maybe not necessary)
- MEG source modeling: Do reconstruction only for a subset of sensors for estimating dipoles?
- Processes compute head model and sources: Additional option to set the file comment
- Time-frequency beamformers:
- Band-pass everything in different frequency bands + Source estimation + TF
- Ask data to Sarang where he sees effects that cannot be extracted with MN followed by TF
- Display volume scouts and surface scouts at the same time
- Process "Extract scouts time series": Add PCA option (replace isnorm with choice PCA/Norm)
- BEM: Fix unstable results when one vertex is too close from the layers (5mm ?)
Anatomy
- Project all sub-cortical structures to default anatomy
- Warping: Scale option has to be fixed, it is currently very unstable
- Scouts:
- Display edges in the middle of the faces instead of the vertices
- Project scouts betweens subjects and between hemispheres
- Display scouts in a tree: hemisphere, region, subregion
- Downsample to atlas: allow on timefreq/connect files
- Sort scouts by region in process options
- Co-register MRI and CT for electrodes marking in the MRI Viewer
- Generate mixed density surfaces
- Import / registration:
- Major bug when importing surfaces for an MRI that was re-oriented manually
- Use mid-gray instead of pial surface?
- Smooth surface: Fix little spikes to irregularities in the mesh
Menu head model > Copy to other conditions/subjects (check if applicable first)
- Add cerebellum to default model generated with "Import FS anatomy"
- Add eyes models to attract eye activity
Statistics
- ANOVA: Use LENA functions
- Output = 1 file per effect, all grouped in a node "ANOVA"
- Display several ANOVA maps (from several files) on one single figure, using a "graphic accumulator", towards which one can send any type of graphic object
- Permutation tests:
- t-test only (wilcoxon? sign-test?): paired, equal var, unequal var
- nb permutations ~ 1000
- maximum statistic over "time" or "time and space"
- Permutations / clustering: cf fieldtrip
Threshold in time: keep only the regions that are significative for contiguous blocks of time, or over a certain number of time points
=> Process that creates a static representation of a temporal window- t-test on volume sources
Paired t-test on unconstrained sources: (convert to flat + Z-score) => AnneSo
- Question of Gaussianity of the samples: take a subset of samples + Kolmogorov-Smirnov / Shapiro-Wilk test
http://www.mathworks.fr/fr/help/symbolic/mupad_ug/perform-shapiro-wilk-test.html
http://www.mathworks.fr/fr/help/symbolic/mupad_ref/stats-swgoft.html
http://stackoverflow.com/questions/14383115/shapiro-wilk-test-in-matlab
- Create icons for Stat/PAC, Stat/Sprectrum, etc.
- One sample t-test across subjects
Input / output
- Finish MINC/CIVET integration (finir lecture MINC2: P Bellec)
- Send email to CIVET mailing list when done
FieldTrip structures: In / Out (see fieldtrip/utilities/ft_datatype_*)
- EEG File formats:
EEG CeeGraph
- EGI: Finish support for epoched files (formats 3,5,7)
- BCI2000 Input (via EEGLAB plugin)
- EEGLAB import:
- Selection of conditions in script mode
- Support for binary AND epoched files (now it's one or the other)
- Allow epoched files with recordings saved in external files (now external files implies continuous recordings)
- BST-BIN: Add compression
- Review raw on all the file formats (ASCII EEG and Cartool missing)
Distribution & documentation
- Document iEEG in "What's new"
- Rewrite basic 12+3 tutorials: group in one series
- Illustrate 2D Layout
- Illustrate unconstrained sources
- Cleaning threads on the forum
Add Help buttons and menus (in popups, dialog windows...) => Links to the website.
- Publication list: Fold by years
- Finish existing tutorials:
- Dipoles
- Auditory: Extend to MNE/EEGLAB/SPM
- Auditory: Finish scripts
- Group MEM/Epilepsy + Epilepsy tutorials
- New tutorials:
- MEG connectome
- Scrambled faces (SPM/MNE-Python)
- Describe all the processes
- Statistics
- Coherence (cortico-muscular ?)
- Intra-cranial recordings (Average ref by groups using Comment field)
- Co-register MEG runs (Beth)
- Missing in the introduction tutorials:
- Volume scouts
- First steps: Brainstorm preferences
- First steps: Temporary folder
- Exploration: Clusters
- Headmodel: explain the fields + how to get the constrained leadfield
- Sources: Model evaluation (by simulating recordings)
- Sources: Theshold min. size (not documented yet)
- Time-frequency: Description of "log freq scale" option
- Modify a structure manually: Export to Matlab/Import from Matlab
- Missing in tutorial "Export to SPM": Add section "Compare with Brainstorm"
- Missing in page "Cite Brainstorm": Add all the methods used in the software
- Reference tutorials on Google scholar
Play videos on wiki with <video> tag (save videos in .ogg)
Current bugs
- Workshops:
- Create scouts doesn't work: scout created on the other side of the brain
- Import anatomy folder: Out of memory on Win 32bits (restart Matlab)
- Compute head model: Out of memory on Win 32bits
- Bandpass filter: Out of memory (Auditory workshop)
- Bug workshop Michael (Mint 12/gnome3/linux 3.0.0-12, KWin/Mutter/Compiz)
- Cannot import two .ds folders at once
- Colors inverted in the PSD/TF plots (power vs. log)
- Cannot type the name of a channel in "Detect ECG"
- Image viewer: Difficult to get to 100%
- Canolty maps computation: Fix progress bar
- Smooth TF windows that contain multiple plots
- Record tab: Text of epoch number is too big on MacOS
- in_bst_data_multi: If trials have different sizes, output is random (the one of the first file)
- tree_dependencies: sources files, reprojected on default anatomy; If based on data files that are bad trials, they should be ignored by tree_dependencies, and they are not
- Image viewer has some bugs on some systems
- Screen capture when there is a fading effect in the window manager: captures the window
- Close figure with coherence results should hide the "frequency" slider
- Edit scout in MRI: small modifications cause huge increase of the scout size
- Reports: Text size is too small with Java 1.5 (2006b-2007a)
- Optimize MRI viewer with patch() instead of image()
- Matlab 2014b bug with rmdir/movefile: Enter but never returns from the call
- 2DLayout (time series):
- Sometimes the lines are not visible
- Does not work when DC offset is not removed
- 2DLayout (TF): Images are too far apart with EEG 20 channels
- Colormap menus: Do not work well on compiled MacOSX 10.9.5 and 10.10
- Event markers are not visible anymore with the sequence: Open MEG, open EOG, close MEG.
Geeky programming details
- Removing all the CTRL and SHIFT in the keyboard shortcuts
- Hide Java panels instead of deleting them
- mri2scs: convert arguments to meters
- Interpolations: Use scatteredInterpolant, griddedInterpolant, triangulation.nearestNeighbor (Matlab 2014b)
- bst_warp and channel_project: Use tess_parametrize_new instead of tess_parametrize
- Shared kernels: do the "get bad channels" operation in a different way (reading all the files is too slow)
- Optimize bst_get:
- Now study and subject have necessarily the same folder name
- Replace big switch with separate functions
- Progress bar:
- Add different levels (to handle sub-processes)
- Make work correctly with RAW on resting tutorial
- Uniformize calls in bst_process/Run
- Add a "Cancel" button
- Line smoothing / anti-aliasing (time series figures)
- Fix all the 'todo' blocks in the code
- Replace handle "0" with bst_get('groot')
- At the end of bst_startup in compiled mode, replace loop with waitfor(jFrame)
- Error message: Add a link to report directly the bug on the forum
in_bst_results (isFull=1): DataFile should be relative