| Size: 27621 Comment:  | Size: 27678 Comment:  | 
| Deletions are marked like this. | Additions are marked like this. | 
| Line 13: | Line 13: | 
| ==== Functional connectivity ==== * Significance thresholding of the connectivity matrices (not started) | |
| Line 342: | Line 341: | 
| * Add menu to import implantation channel file in imported recordings | |
| Line 348: | Line 348: | 
| * ECOG: Method for contacts projection: https://pdfs.semanticscholar.org/f10d/6b899d851f3c4b115404298d7b997cf1d5ab.pdf | |
| Line 365: | Line 366: | 
| * PLS: Partial Least Squares | 
What's next
A roadmap to the future developments of Brainstorm.
Contents
Current topics
Electrophysiology
- Spike sorting interface based on WaveClus 
Source modeling
- Implementation of a new unified minimum norm/beamformer framework (almost finished)
Computation
- Removing the dependence to the Java interface to run in headless mode (not started)
- Call MNE-Python and FieldTrip functions from Brainstorm GUI (work in progress) 
 
Recordings
- RAW file viewer: 
 - Downsample before filtering? (attention to the filter design)
- Add parameter to make the visual downsampling more or less aggressive
- Pre-load next page of recordings
- Keep the filter specifications in memory instead of recomputing for every page
- Add field "comment" to markers: For clinicians to add notes (Marcel)
- Events: Change the category of a selected event easily, instead of deleting/marking new
- Events: Advanced process for recombining. 
 Example: http://www.erpinfo.org/erplab/erplab-documentation/manual/Binlister.html
 
- EEG: Laplacian montage (see doc sent by Jeremy)
- Bad trials: When changing the status of bad to good: remove the bad segments as well, otherwise it is not processed by processes like the PSD.
- Review clinical recordings: Reduce the dimensionality of the data with a simple inverse problem, similar to what we do for the magnetic extrapolation ("Regional sources" in BESA, cf S Rampp)
- MEG/EEG registration: Apply the same transformation to multiple runs
- 2DLayout: - Overlay multiple conditions
- Does not work when DC offset is not removed
- Add a proper amplitude scale that gets updated when shift+scroll, to compare figures
- Update the vertical lines when changing the gain (shift+scroll)
 
- Create heat maps: Maybe with matlab function heatmap?
Interface
- Add a warning when computing a forward model with > 100000 sources (check selection) 
- Start Brainstorm without Java (-nodesktop)
- Multiple screens: Add option to set on which display the main bst window should be
- File filters: Add boolean logic: https://github.com/brainstorm-tools/brainstorm3/issues/68 
- Snapshot: Save as image / all figures (similar to Movie/all figure)
- Generalize the use of the units (field .DisplayUnits): Rewrite processes to save the units correctly 
- Colormaps: - Allow brightness/contrast manipulations on the custom colormaps
- Create a colormap similar to MNE, where extrema are bright
- Global colormap max: Should get the maximum across all the open files
 
- Open new figures as tab (docked in the Figures window)
- Copy figures to clipboard (with the screencapture function)
- Removing all the CTRL and SHIFT in the keyboard shortcuts
- Display warning before opening files that are too big
- Smooth display from figure_image (ERPimage, raster plot...)
- Contact sheets & movies: use average of time windows instead of single instants, for each picture. 
- Contact sheets: Allow explicit list of times in input (+ display as in MNE-Python with TS)
- Display CTF coils: Show discs instead of squares
- Use boundary() instead of conhull() in all the display functions (ie. 2DDisc)
Connectivity
- Thresholding and stat tests the connectivity matrices
- Connectivity on unconstrained sources: "Default signal extraction for volume grids should be the time series of the first principal component of the triplet signals after each has been zero-meaned" (SB)
- Display of connectivity graphs: - Display as straight lines
- Recode 2D graphs
- 3D display with anatomical constrains
 
- Use new band-pass filters in bst_connectivity ('bst-hfilter' instead of 'bst-fft-fir')
- Review by Jan-Mathijs: http://journal.frontiersin.org/article/10.3389/fnsys.2015.00175/full 
- Connectivity based on band limited power (Sylvain): - Compute Hilbert/Bandpass + correlation of the envelopes
- Bandpass envelopes before computing correlations?
- Compute Hilbert(sensors) and then project to source space?
 
- Matrix view of NxN graphs: Add legend of the elements along X and Y axis
- Graph view: - Does not display negative values correctly (correlation or difference of coherence)
- Re-write using pure Matlab code and smoothed graphics
- Fixed scales for intensity sliders
- Text bigger
- Too much data in appdata
- Fixed scales for intensity sliders
- Add "=" shortcut for having graphs with similar configurations
- Disable zoom in one region (serious bugs)
- NxN on sensors: does not place the sensors correctly in space
 
- Coherence: - Average cross-spectra instead of concatenating epochs (to avoid discontinuities) 
 Explore inter-trial approaches (Esther refers to chronux toolbox)
 
- Granger: - Crashes sometimes: improve stability
- Check for minimum time window (Esther: min around 500-1000 data points)
- Re-write and optimize code
- Add progress bar
 
- PLV: - Add p-values
- Remove evoked
- Optimize code
- Add time integration
- Unconstrained sources
- Add warning when running of short windows (because of filters)
 
- PAC: - Add input TF , to disconnect TF decomposition and PAC computation (Peter)
- Refine frequency vector of low frequencies
- How many central frequencies to use in bst_pac?
- Change filters: no chirplet functions
- bst_freqfilter: Use nfcomponents like in bst_pac
- Esther recommended a larger frequency binning of the PAC estimation
- PAC maps: Display all sensors at once (like TF and DynamicPAC)
 
- Hui-Ling's PAC:
- Time-resolved correlation/coherence: Display as time bands
- Other metrics: - Coherence by bands: bst_coherence_band_welch.m
- Granger by bands: bst_granger_band.m
- Inter-trial coherence
 
- Tutorial coherence [1xN] : Reproduce FieldTrip results? 
- Connect NxN: Display as time series > Display warning before trying to open too many signals 
Processes
- Use CUDA for speeding up some operations (filtering, wavelets, etc)
- Allow processes in Python and Java
- Add MNE-Python functions: - scikit-learn classifiers: S Marti / G Dehaene
- Implement data exchange with MNE-Python: write FIF files from Brainstorm and/or pass python objects in memory instead of FIF files
- SSS/tSSS cleaning
- Reproduce other tutorials / examples
- Change the graphic renderer from Matlab
 
- Add FieldTrip functions: - ft_sourceanalysis: - Check noise covariance
- Check all the options of all the methods
- Single trial reconstructions + noise covariance?
- Filters?? http://www.fieldtriptoolbox.org/example/common_filters_in_beamforming 
- Beamformers: Save ftSource.avg.mom 
 http://www.fieldtriptoolbox.org/workshop/meg-uk-2015/fieldtrip-beamformer-demo
- http://www.fieldtriptoolbox.org/tutorial/beamformingextended 
- Baseline? Two inputs?
 
- ft_prepare_sourcemodel: Compute MNI transformation (linear and non-linear) => Peter 
- Freqanalysis: ITC
- ft_read_atlas('TTatlas+tlrc.BRICK');
- ft_volumereslice: http://www.fieldtriptoolbox.org/faq/how_change_mri_orientation_size_fov 
- ft_freqanalysis
- ft_combineplanar
- Allow FieldTrip functions in compiled version 
 
- ft_sourceanalysis: 
- Decoding/Classifiers: Faster algorithms (MNE-Python?)
- Pipeline editor: - Bug: After "convert to continuous", the time of the following processes should change
- Add loops over subjects/conditions/trial groups
 
- ITC: Inter-trial coherence (see MNE reports for group tutorial) 
 http://www.sciencedirect.com/science/article/pii/S1053811916304232
- ICA: - Why doesn't the ICA process converge when using 25 components in the EEG tutorial?
- Add an option to resample the signals before computing the ICA decomposition
- Add a stand-alone tutorial
- Exploration: Add window with spectral decomposition (useful for muscle artifacts)
- Export IC time series (and then compute their spectrum): solves the problem above
- Comparison JADE/Infomax: 
 http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0030135
- Use faster methods (MNE-Python?)
- Add methods: SOBI, Fastica, AMICA/CUDICA (recommended by S Makeig)
- Dimension reduction with PCA adds artifacts: Not done by default in EEGLAB 
 Contact: Stephen Shall Jones ( shall-jones@infoscience.otago.ac.nz )
 Student Carl Leichter detailed this in his thesis
- S Makeig: Use ICA to select the IC of interest instead of only removing artifacts
- Display of spectrum for components (PSD/FFT)
- Use FastICA (algo crashing)
- Add components preselection: Correlation with EOG/ECG
- Import ICA matrices available in EEGLAB .set files
- EEGLAB recommends ICA + trial rejection + ICA again: Impossible right now with Brainstorm 
 (http://sccn.ucsd.edu/wiki/Chapter_09:_Decomposing_Data_Using_ICA)
- ICA+machine learning: https://www.ncbi.nlm.nih.gov/pubmed/28497769 
- Automated artifact rejection: https://arxiv.org/abs/1612.08194 
- Save IC time series in database
 
- SSP: - Display warning if changing the ChannelFlag while there is a Projector applied 
- Show where the attenuation is projected: 
 (sum(IK,2)-sum(SSP(k,:)*IK,2)./sum(IK,2)
 
- Pipeline editor: - When computing sources from the pipeline editor: doesn't reselect the options if you click twice on "edit" (works for minnorm, but not for lcmv)
- When computing time-frequency/hilbert/psd: Find a way not to force the user to click on Edit
 
- Bandpass: - Use new filters in all the functions using a bandpass ('bst-hfilter' instead of 'bst-fft-fir'): process_evt_detect_threshold
- Weird bug: Filter(import) != Import(Filter) in the HCP tutorial... to investigate
 
- Bandpass
- Spectral flattening (John): - ARIMA(5,0,1): Apply on the signal before any frequency/connectivity/PAC analysis
 
- PSD: - Rewrite to have the same input as coherence (frequency resolution instead of window length)
- Use the progress bar
- Allow display of Avg+StdErr 
 
- Remove line noise: http://www.nitrc.org/projects/cleanline 
- Use Matlab Coder to optimize some processes: Wavelets, bandpass filter, sinusoid removal
- Reports: Click on link reopens exactly the figure
- Time-frequency: - Optimization: bst_timefreq (around l.136), remove evoked in source space: Average should be computed in sensor space instead of source space (requested by Dimitrios)
- Short-time Fourier transform: http://www.mikexcohen.com/lectures.html 
- Matching pursuit: http://m.jneurosci.org/content/36/12/3399.abstract?etoc 
- Bug: Display logs as negative
- Bug: 3D figures: Colormaps with "log" option doesn't work
- Bug: Difference of power displayed in log: problems (Soheila)
- 2D Layout in spectrum
- Make much faster and more memory efficient (C functions coded by Matti ?)
- TF scouts: should display average of TF maps
- Impossible to keep complex values for unconstrained sources
- Pad short epochs with zero values for getting lower frequencies
- Hilbert with time bands very slow on very long files (eg. 3600s at 1000Hz) because the time vector is still full (10^7 values): save compressed time vector instead.
- Extend clusters tab to display of TF to overlay TF signals (Svet)
- When normalizing with baseline: Propagate with the edge effects marked in TFmask
- Allow running TF on montages
- Review continuous files in time-frequency space (for epilepsy)
- Bug when computing TF on constrained and unconstrained scouts at the same time (in mixed head models for instance): uses only the constrained information and doesn't sum the 3 orientations for the unconstrained regions.
 
- Artifact detection: - Artifact rejection like SPM: if bad in 20%, bad everywhere
- Test difference between adjacent samples
 
- Events detection: Add option "std" vs "amplitude"
- Co-registration of MEG runs: - SSP: Group projectors coming from different files
- Finish validation of the method
- Apply to continuous recordings for correcting head movements
 
- Other processes: - Moving average
- Max
- Median
 
- Simulation: - Fix units in simulation processes => no *1e-9 in "simulate recordings" 
- Use "add noise" process from Hui-Ling (in Work/Dev/Divers)
 
- Use field process field "Group" to separate Input/Processing/Output options
- Use new Matlab functions: movmean, movsum, movmedian, movmax, movmin, movvar, movstd
- Process ft_prepare_heamodel: Add support from BEM surfaces from the Brainstorm database
Database
- Add buttons to sort files: by name, by comment, by date
- MEG protocols: More flexible organization of the database; sub-conditions to allow different runs X different conditions.
- Matrix files: Allow to be dependent from other files
- Add notes in the folders (text files, visible as nodes in the tree)
- Screen captures: save straight to the database
- Rename multiple files
- Default headmodel lost when reloaded: Keep selection on the hard drive (in brainstormstudy.mat)
- protocol.mat can be too big: do not store the results links in it (and recreate when loading)- http://neuroimage.usc.edu/forums/t/abnormally-slow-behavior/2065/10 
Distributed computing
- Options from FieldTrip: - Loose collection of computers: https://github.com/fieldtrip/fieldtrip/tree/master/peer 
- Alternative, with less limitations: http://research.cs.wisc.edu/htcondor/ 
- Single multicore machine: https://github.com/fieldtrip/fieldtrip/tree/master/engine 
- Batch system: https://github.com/fieldtrip/fieldtrip/tree/master/qsub 
- Documentation: http://fieldtrip.fcdonders.nl/faq#distributed_computing_with_fieldtrip_and_matlab 
 
- Various initiatives: http://samirdas.github.io/Data_sharing.html#/ 
Source modeling
- Project sources: Very poor algorithm to project sub-cortical regions and cerebellum (algorithm to fit surfaces should be imrpoved)
- Menu head model > Copy to other conditions/subjects (check if applicable first) 
- Menu Sources > Maximum value: Doesn't work with volume or mixed head models 
- Mixed head models: 
 - Set loose parameter from the interface
 
- Volume grid: - Optimize: 3D display (better than 9x9 cubes)
- Optimize: vol_dilate (with 26 neighbors)
 
- Menu Sources > Simulate recordings: - Do not close the 3D figures after generating a new file
- Add a process equivalent to this menu
 
- Panel Get coordinates: Add button "find maximum"
- Dipoles: - Project individual dipoles files on a template
- panel_dipoles: Doesn't work with multiple figures
 
- BEM single sphere: Get implementation from MNE
- Visualize Beamformer results: - Read CTF SAM .svl
- Display as layers in the MRI viewer
 
- Unconstrained sources: - Stat and connectivity: what to do? (re-send email John+Sylvain)
 
- Overlapping spheres: improve the estimation of the spheres for the frontal lobes
- Magnetic extrapolation: Do the same thing with EEG
- Noise covariance matrix: - Display with figure_image()
- Storage of multiple noise covariance matrices (just like the head models)
- Always save as full, then at inversion time, we can decide between full, heteroskedastic (diagonal) or homoskedastic (i.i.d, scalar)
- Problem of having inividual trials + averages in the condition => Display warning or not? 
- Save nAvg in noisecov file, to make it easier to scale to other recordings
 
- Sources on surface: Display peak regions over time (time = color) => A.Gramfort 
- Calculate ImagingKernel * Gain for a scout 
- Time-frequency beamformers: - Band-pass everything in different frequency bands + Source estimation + TF
- Ask data to Sarang where he sees effects that cannot be extracted with MN followed by TF
 
- Process "Extract scouts time series": Add PCA option (replace isnorm with choice PCA/Norm)
- BEM: Fix unstable results when one vertex is too close from the layers (5mm ?)
- Hui-Ling beamformers: - More explanations about what is in NAI and Spatial filters
- Explain that is this is better to study effects extended in time (Ntime > Nsensors) 
- Group LCMV+MCB
- Condition LEFT median nerve: very bad results
 
- Keep options for inverse computation
- OpenMEEG: Post example datasets for the remaining issues: - Example protocol ECOG: doesn't work
 
- Add eyes models to attract eye activity
Anatomy
- Registration: - Use the same registration for multiple recording sessions that have already re-registered previously (eg. with MaxFilter) 
- Check templates: MNI transformation and volume atlases for ICBM152 vs Colin27 (loading the AAL atlas as surface or voume scouts do not align well on the ICBM152)
- Compute non-linear MNI registration instead of linear
- Select and remove bad digitized head points before automatic coregistration
- Load the MNE -transf.fif: http://neuroimage.usc.edu/forums/showthread.php?2830 
 
- MRI Viewer: - Pan in zoomed view (shift + click + move?)
- Zoom in/out with mouse (shift + scroll?)
- Ruler tool to measure distances
- Add keyboard shortcuts to scroll in the three orientations (same in MRI 3D)
- Display scouts as additional volumes
- Render surface envelope in the MRI as a thin line instead of the full interpolation matrix
- Edit fiducials: Replace 6 text boxes with 1 for easy copy-paste (see fiducials.m)
- Optimize computation interpolation MRI-surface (tess_tri_interp) => spm_mesh_to_grid 
 
- BrainVISA: Add support for MarsAtlas (Guillaume A) 
- BrainSuite: - Use BrainSuite inner skull for surface generation 
- Use same colors for left and right for anatomical atlases
 
- Scouts: - Display edges in the middle of the faces instead of the vertices
- Display scouts in a tree: hemisphere, region, subregion
- Sort scouts by region in process options
- Downsample to atlas: allow on timefreq/connect files
- Project from one hemisphere to the other using registered spheres/squares (http://neuroimage.usc.edu/forums/t/how-to-create-mirror-roi-in-the-other-hemisphere/5910/8) 
 
- Parcellating volume grids: scikit-learn.cluster.Ward
- Major bug when importing surfaces for an MRI that was re-oriented manually
- Smooth surface: Fix little spikes due to irregularities in the mesh
- Bug: Hide scouts in the preview of the grid for volume head models
ECOG/SEEG
- Contact positions: Import / set / detect 
 - Add history: Save modifications and transformations applied to the channel files (Marcel)
- ECOG: How to handle cases where not all the grid contacts are in the channel file? (Marcel)
- Project contact positions across subjects or templates (Marcel)
- ECOG: Default names of contacts?
- Add menu to import implantation channel file in imported recordings
 
- Editable list of montages shortcuts
- Automatic segmentation of CT:
- ECOG: Project and display contacts on cortex surface should consider the rigidity of the grids: Contacts cannot rotate, and distance between contacts should remain constant across runs
- ECOG: Method for contacts projection: https://pdfs.semanticscholar.org/f10d/6b899d851f3c4b115404298d7b997cf1d5ab.pdf 
- ECOG: Brain shift: When creating contact positions on a post-implantation image, the brain shift should be taken into account for creating images of the ECOG contacts on the pre-op brain => iELVis (http://ielvis.pbworks.com/w/page/116347253/FrontPage) 
- Display: - Bad channels: Contacts greyed out instead of ignored (Marcel)
- Display time in H:M:S
- Display curved SEEG electrodes
 
- Re-referencing: - Create new average reference montages with a specific list of channels, with the possibility to edit the order of the channels (for Jeremy)
- Closest white reference (Arnulfo)
 
- Alternatives to OpenMEEG: SimBio/FieldTrip? Matti Stenroos? NFT/NIST? 
Statistics
- ANOVA: - Use LENA functions(?)
- Output = 1 file per effect, all grouped in a node "ANOVA"
- Display several ANOVA maps (from several files) on one single figure, using a "graphic accumulator", towards which one can send any type of graphic object
 
- New process to test for Gaussianity using swtest
- Simulate recordings with specific properties, for stat validation
- Quality control before statistics, on condition averages across subjects: 
 mean(baseline)/std(baseline): shows bad subject quickly.
- Use SurfStat: Impements interesting things, like an analytical cluster-based p-value correction (Random-field theory which is used in SPM) - Peter 
Input / output
- XDF import: Use the EEGLAB plugin, contact Martin Bleichner (Oldenburg) 
- Output .nii have incorrect sform/qform when using the options to downsample the volume of cut the empty slices
- DICOM converter: - Add dcm2nii (MRICron)
- Add MRIConvert
 
- FieldTrip: Import/Export time-frequency: 
- 4D file format: - Use reader from MNE-Python: mne.io.read_raw_kit (doesn't require Yokogawa slow library)
- Reference gradiometers: Keep the orientation of the first or second coil?
- Reference gradiometers: Add the sensor definition from coil_def.dat
- Validate with phantom recordings that noise compensation is properly taken into account
- References at too far from the head sensors in Marseille 4D system
- The noise compensation is considered to be always applied on the recordings, not sure this assumption is always correct
- 4D phantom tutorial (JM Badier?)
 
- EEG File formats: - EEG CeeGraph 
- EGI: Finish support for epoched files (formats 3,5,7)
- Persyst .lay: https://github.com/ieeg-portal/Persyst-Reader 
- Nervus .eeg: https://github.com/ieeg-portal/Nervus-Reader 
- Biopac .acq: https://github.com/ieeg-portal/Biopac-Reader 
- gTec EEG recordings: Read directly from the HDF5 files instead of the Matlab exports.
 
- BCI2000 Input (via EEGLAB plugin)
- EEGLAB import: - Support for binary AND epoched files (now it's one or the other)
- Allow epoched files with recordings saved in external files
 
- BST-BIN: Add compressionto .bst
- Review raw on all the file formats (ASCII EEG and Cartool missing)
- SPM .mat/.dat: Fix the import of the EEG/SEEG coordinates
- Get acquisition date from files: Missing for 4D
Distribution & documentation
- Compile with FieldTrip and SPM 
- Add tags to the forum posts for easier listing by topic
- Tutorial OMEGA/BIDS: - Add review of literature for the resting state MEG
- Download example datasets directly from the OMEGA repository
 
- New tutorials: - Visual group Henson/Wakeman tutorial: Use the BIDS version 
 https://github.com/INCF/BIDS-examples/tree/bep008_meg/ds000117
- Other public datasets: https://github.com/INCF/BIDS-examples/tree/bep008_meg/ 
- Rat PAC + high gamma (Soheila)
- EEG/research
- FieldTrip ECOG tutorial: http://www.fieldtriptoolbox.org/tutorial/human_ecog 
- FieldTrip cortico-muscular coherence tutorial: http://www.fieldtriptoolbox.org/tutorial/coherence 
- Reproduce tutorials from MNE-Python: https://martinos.org/mne/stable/tutorials.html 
- Cam-CAN database: https://camcan-archive.mrc-cbu.cam.ac.uk/dataaccess/<<BR>>(download new datasets, including maxfiltered files and manual fiducial placements) 
 
- MEG steady-state / high-gamma visual / frequency tagging
- BIDS-EEG example datasets
- Intra-cranial recordings (Marcel, Jeremy?)
- Stand-alone ICA tutorial
- Co-register MEG runs (Beth)
- Move all the files to download on the cloud for faster download everywhere in the world
- Provide secure way of sending password over HTTPS for: - Account creation
- Forum exchanges
- org.brainstorm.dialog.CloneControl 
 
- Workflows FieldTrip: http://www.fieldtriptoolbox.org/faq/what_types_of_datasets_and_their_respective_analyses_are_used_on_fieldtrip 
- Reference tutorials on Google scholar + ResearchGate 
- Count GitHub clones in the the download stats 
- Google Analytics: Create template and update the section of the Community page
- Missing in page "Cite Brainstorm": Add all the methods used in the software
- Deface the MRIs of all the tutorials
- Compiled R2016b: Color picker doesn't work (for changing surface color for instance)
Current bugs
- Screen capture: - Bug on Win8/Win10: doesn't capture the correct part of the screen
- Window managers with fading effect: captures the top window
 
- Image viewer: - Difficult to get to 100%
- Buggy on some systems
 
- 2DLayout: - (TF) Units are weird with % values
- (TF) Difficult to navigate in frequencies: Scaling+changing frequency resets the scaling
 
- Progress bar: - Doesn't close properly on some Linux systems
- Focus requests change workspace when processing constantly (Linux systems)
 
- MacOS bugs: - Buttons {Yes,No,Cancel} listed backwards
- Record tab: Text of epoch number is too big
- Colormap menus: Do not work well on compiled MacOSX 10.9.5 and 10.10
 
- Matlab bugs: - Interface looks small on screens with very high resolutions: Reduce the resolution
 
- Event markers are not visible anymore with the sequence: Open MEG, open EOG, close MEG
- in_bst_data_multi: If trials have different sizes, output is random (the one of the first file)
- Edit scout in MRI: small modifications cause huge increase of the scout size
- Canolty maps computation: Fix progress bar
Geeky programming details
- bst_bsxfun: After 2016b, we can use directly the scalar operators (./ .* ...) instead of bsxfun. Update bst_bsxfun to skip the use of bsxfun when possible.
- Interface scaling: Rewrite class IconLoader to scale only once the icons at startup instead of at each request of an icon (might improve the speed of the rendering of the tree) 
- Hide Java panels instead of deleting them
- Processes with "radio" and "radio_line" options: Replace with "radio_label" and "radio_linelabel"
- Interpolations: Use scatteredInterpolant, griddedInterpolant, triangulation.nearestNeighbor (2014b)
- bst_warp and channel_project: Use tess_parametrize_new instead of tess_parametrize
- Shared kernels: "get bad channels" operation in a different way (reading all the files is too slow)
- Optimize bst_get: - Now study and subject have necessarily the same folder name
- Replace big switch with separate functions
 
- Progress bar: - Add different levels (to handle sub-processes)
- Make work correctly with RAW on resting tutorial
- Uniformize calls in bst_process/Run
- Add a "Cancel" button
 
- Fix all the 'todo' blocks in the code
- Error message: Add a link to report directly the bug on the forum