This page provides a precompiled Matlab implementation ("p-code:) of a distortion correction method for diffusion MRI using the interlaced q-space sampling technique. This method uses interlaced phase-encoding directions (IPED) while sampling the q-space, which enables accurate distortion correction without increasing the acquisition time. Please see following references for more details of the method: | This page provides a precompiled Matlab implementation ("p-code") of a distortion correction method for diffusion MRI using the interlaced q-space sampling technique. This method uses interlaced phase-encoding directions (IPED) while sampling the q-space, which enables accurate distortion correction without increasing the acquisition time. Please see following references for more details of the method: |
Line 9: | Line 9: |
=== Data acquisition === {{attachment:4IPED_small.png||align="right"}} This implementation makes several assumptions about the data acquisition and sampling pattern in the q-space. All of the following must be satisfied for accurate correction: * The diffusion data should be scanned with single-shot Echo Planar Imaging (EPI) sequence. * The EPI planes for data acquired with different phase encoding directions (PED) must coincide. This also implies that ignoring the polarity of PEDs there could be maximum of two PEDs, one along each dimension of 2D EPI plane (without ignoring the polarity of PEDs there could be maximum of four PEDs). * Atleast two different PEDs must be used to sample the q-space. * All the diffusion weighted images must be acquired with a single b-value ''i.e.'' assumes single-shell acquisition (multi-shell acquisition can also be used - by correcting diffusion data for each shell separately). * Atleast one diffusion image must be acquired with (almost) no diffusion weighting (b-value of zero) for each unique PED. * The inhomogeneity in main magnetic field (B0) should be same across all diffusion weighted images ''i.e.'' all the diffusion images must be acquired with same shim settings. * The field of view, voxel resolution, image matrix size, number of slices and slice thickness should be consistent across all images. <<BR>> Further, take note about following to enable accurate distortion correction with IPED method with this implementation: * It is recommended to use more than 20 unique diffusion encoding directions. Larger number of diffusion encoding direction would enable better correction. * The diffusion encoding directions should be evenly distributed on the sphere (or one hemisphere). * The diffusion encoding directions for each PEDs should be evenly interlaced ''i.e.'' encoding directions should be evenly distributed for each unique PED as well as for intersection of all PEDs. * In case of multi-shell acquisition, the above recommendation applies to each shell. * This implementation also works with reversed-gradient ([[http://dx.doi.org/10.1109/42.158935|Chang and Fitzpatrick, 1992]]) and its generalized acquisition schemes. Also see {{{user_opts}}} below. |
|
Line 11: | Line 32: |
The method is implemented in form of a Matlab function, named {{{IPEDcorrect}}}, and requires [[http://www.mathworks.com/products/image/|Image processing toolbox]]. It only supports use of [[http://nifti.nimh.nih.gov/nifti-1|NIfTI-1 data format]] for image and plain text-files for specifying other parameters. Either of following syntax is supported:{{{ | The distortion correction method is implemented as a Matlab function, named {{{IPEDcorrect}}}, and requires [[http://www.mathworks.com/products/image/|Image processing toolbox]]. It only supports use of [[http://nifti.nimh.nih.gov/nifti-1|NIfTI-1 data format]] for image and plain text-files for specifying other parameters. Either of following syntax is supported:{{{ |
Distortion correction using interlaced q-space sampling
This page provides a precompiled Matlab implementation ("p-code") of a distortion correction method for diffusion MRI using the interlaced q-space sampling technique. This method uses interlaced phase-encoding directions (IPED) while sampling the q-space, which enables accurate distortion correction without increasing the acquisition time. Please see following references for more details of the method:
C. Bhushan, A. A. Joshi, R. M. Leahy and J. P. Haldar (2014), Improved B0-distortion correction in diffusion MRI using interlaced q-space sampling and constrained reconstruction. Magnetic Resonance in Medicine, 72: 1218-1232. doi: 10.1002/mrm.25026
C. Bhushan, A. A. Joshi, R. M. Leahy and J. P. Haldar (2013), Accelerating data acquisition for reversed-gradient distortion correction in diffusion MRI: A constrained reconstruction approach. 21st Scientific Meeting of International Society for Magnetic Resonance in Medicine (ISMRM), Salt Lake City, p. 55. Abstract PDF, ISMRM presentation video
Data acquisition
This implementation makes several assumptions about the data acquisition and sampling pattern in the q-space. All of the following must be satisfied for accurate correction:
- The diffusion data should be scanned with single-shot Echo Planar Imaging (EPI) sequence.
- The EPI planes for data acquired with different phase encoding directions (PED) must coincide. This also implies that ignoring the polarity of PEDs there could be maximum of two PEDs, one along each dimension of 2D EPI plane (without ignoring the polarity of PEDs there could be maximum of four PEDs).
- Atleast two different PEDs must be used to sample the q-space.
All the diffusion weighted images must be acquired with a single b-value i.e. assumes single-shell acquisition (multi-shell acquisition can also be used - by correcting diffusion data for each shell separately).
- Atleast one diffusion image must be acquired with (almost) no diffusion weighting (b-value of zero) for each unique PED.
The inhomogeneity in main magnetic field (B0) should be same across all diffusion weighted images i.e. all the diffusion images must be acquired with same shim settings.
- The field of view, voxel resolution, image matrix size, number of slices and slice thickness should be consistent across all images.
Further, take note about following to enable accurate distortion correction with IPED method with this implementation:
- It is recommended to use more than 20 unique diffusion encoding directions. Larger number of diffusion encoding direction would enable better correction.
- The diffusion encoding directions should be evenly distributed on the sphere (or one hemisphere).
The diffusion encoding directions for each PEDs should be evenly interlaced i.e. encoding directions should be evenly distributed for each unique PED as well as for intersection of all PEDs.
- In case of multi-shell acquisition, the above recommendation applies to each shell.
This implementation also works with reversed-gradient (Chang and Fitzpatrick, 1992) and its generalized acquisition schemes. Also see user_opts below.
Usage
The distortion correction method is implemented as a Matlab function, named IPEDcorrect, and requires Image processing toolbox. It only supports use of NIfTI-1 data format for image and plain text-files for specifying other parameters. Either of following syntax is supported:
IPEDcorrect(IPED_config_filename, fieldmap_filename, echo_spacing, output_base) IPEDcorrect(IPED_config_filename, fieldmap_filename, echo_spacing, output_base, user_opts)
where,
- IPED_config_filename
- fieldmap_filename
- echo_spacing
- output_base
- user_opts
IPED_config_filename
user_opts
Downloads
This code is licensed under the CC Attribution-Noncommercial-Share Alike 4.0 License. Please cite [1] and [2] if you use this code or its derivatives in your own work.
In no event shall the University of Southern California, the Authors, or the Distributors be liable to any party for direct, indirect, special, incidental, or consequential damages, including lost profits, arising out of the use of this software, its documentation, or any derivatives thereof, even if the authors have been advised of the possibility of such damage. The University of Southern California, the Authors, and the Distributors specifically disclaim any warranties, including, but not limited to, the implied warranties of merchantability, fitness for a particular purpose, and non-infringement. This software is provided on an "as is" basis, and the authors and distributors have no obligation to provide maintenance, support, updates, enhancements, or modifications. This software is for research purposes only and has not been approved for clinical use.