Line 24: | Line 24: |
* Finger tapping task: 10 stimulation blocks of 30 seconds each, with rest periods of 30 seconds | * Finger tapping task: 10 stimulation blocks of 30 seconds each, with rest periods of ~30 seconds |
Line 54: | Line 54: |
Here are the MRI coordinates of the fudicials used to produce the above figure: * NAS: * LPA: * RPA: * AC: * PC: |
|
Line 64: | Line 74: |
The functional data used in this tutorial was produced by the Brainsight acquisition software and is available in the NIRS sample folder in S01_Block_FO_LH_Run01.bs. This folder contains the following files: | The functional data used in this tutorial was produced by the Brainsight acquisition software and is available in the NIRS sample folder in S01_Block_FO_LH_Run01.brs. This folder contains the following files: |
Line 66: | Line 76: |
* '''fiducials.txt''': the coordinates of the fudicials (nasion, left ear, right ear).<<BR>>These positions should have been digitized at the same location as the fiducials previously marked on the anatomical MRI. These points will be used by Brainstorm for the registration, hence the consistency between the digitized and marked fiducials is essential for good * '''optodes.txt''': the coordinates of the optodes (sources and detectors), in the same referential as for the fiducials. Note: the actual referential is not relevant here, as the registration will be performed by Brainstorm afterwards. |
* '''fiducials.txt''': the coordinates of the fudicials (nasion, left ear, right ear).<<BR>>The positions of the Nasion, LPA and RPA should have been digitized at the same location as the fiducials previously marked on the anatomical MRI. These points will be used by Brainstorm for the registration, hence the consistency between the digitized and marked fiducials is essential for good results. * '''optodes.txt''': the coordinates of the optodes (sources and detectors), in the same referential as in fiducials.txt. Note: the actual referential is not relevant here, as the registration will be performed by Brainstorm afterwards. |
Line 74: | Line 84: |
* Select file type "NIRS: BS (.bs)" | * Select file type "NIRS: Brainsight (.brs)" |
Line 76: | Line 86: |
* Load the folder "S01_Block_FO_LH_Run01.bs" in the NIRS sample folder. | * Load the file "S01_Block_FO_LH_Run01.nirs" in the NIRS sample folder.<<BR>>Note: the importation process assumes that the files optodes.txt and fiducials.txt are in the same folder<<BR>>as the .nirs data file. |
Line 84: | Line 94: |
* These same three points have also been marked before the acquisition of the NIRS recordings. The person who recorded this subject digitized their positions with a tracking device (such as a Polhemus FastTrak or Patriot). The position of these points are saved in the NIRS datasets (see NIRS_sample/fiducials.txt). * When we bring the NIRS recordings into the Brainstorm database, we align them on the MRI using these fiducial points: we match the NAS/LPA/RPA points digitized with Brainsight with the ones we placed in the MRI Viewer. | * These same three points have also been marked before the acquisition of the NIRS recordings. The person who recorded this subject digitized their positions with a tracking device (here Brainsight). The position of these points are saved in the NIRS datasets (see fiducials.txt). * When we bring the NIRS recordings into the Brainstorm database, we align them on the MRI using these fiducial points: we match the NAS/LPA/RPA points digitized with Brainsight with the ones we placed in the MRI Viewer. |
Line 92: | Line 103: |
If the registration you get with automatic alignment techniques described previously, or if there was an issue when you digitized the position of the fiducials or the head shape, you may have to realign manually the optodes on the head. Right-click on the channel file > MRI Registration: | /!\ TODO? |
Line 94: | Line 105: |
* '''Check''': Show all the possible information that may help to verify the registration. * '''Edit''': Opens a window where you can move manually the MEG helmet relative to the head.<<BR>> Read the tooltips of the buttons in the toolbar to see what is available, select an operation and then right-click+move up/down to apply it. From a scientific point of view this is not exactly a rigorous operation, but sometimes it is much better than using wrong default positions.<<BR>> IMPORTANT: this refinement can only be used to better align the headshape with the digitized points - it cannot be used to correct for a subject who is poorly positioned in the helmet (i.e. you cannot move the helmet closer to the subjects head if they were not seated that way to begin with!) |
To review this registration, right-click on "" -> |
Line 97: | Line 107: |
/!\ '''Add screenshots''' | /!\ add screenshot |
Line 99: | Line 109: |
As reference, the following figures show the position of the fiducials and the optodes as they were digitized by Brainsight: | As reference, the following figures show the position of fiducials [blue] (inion and nose tip are extra positions), sources [orange] and detectors [green] as they were digitized by Brainsight: |
Line 101: | Line 111: |
{{attachment:NIRSTORM_tut1_brainsight_head_mesh_fiducials_1.gif||height="335"}} {{attachment:NIRSTORM_tut1_brainsight_head_mesh_fiducials_2.gif||height="335"}} {{attachment:NIRSTORM_tut1_brainsight_head_mesh_fiducials_3.gif||height="335"}} |
{{attachment:NIRSTORM_tut1_brainsight_head_mesh_fiducials_1.gif||height="280"}} {{attachment:NIRSTORM_tut1_brainsight_head_mesh_fiducials_2.gif||height="280"}} {{attachment:NIRSTORM_tut1_brainsight_head_mesh_fiducials_3.gif||height="280"}} |
Line 110: | Line 120: |
This indicates that the data comes from the Brainsight system (BS) and comprises 97 channels. | /!\ TODO: update screenshot This indicates that the data comes from the Brainsight system (BRS) and comprises 97 channels. |
Line 113: | Line 125: |
/!\ TODO: add screenshot of updated channel table |
|
Line 120: | Line 135: |
||7 ||S1P1WL1 ||NIRS ||NIRS_WL1 ||(PROXY) ||coords S1 ||coords D2 ||coords middle [S1-D2] || || ||8 ||S1P1WL2 ||NIRS ||NIRS_WL2 ||(PROXY) ||coords S1 ||coords D2 ||coords middle [S1-D2] || || |
||7 ||S1P1WL1 ||NIRS ||NIRS_WL1 ||(NIRS_PROX) ||coords S1 ||coords D2 ||coords middle [S1-D2] || || ||8 ||S1P1WL2 ||NIRS ||NIRS_WL2 ||(NIRS_PROX) ||coords S1 ||coords D2 ||coords middle [S1-D2] || || |
Line 124: | Line 139: |
* The channel named "TAPPING" encodes the stimulation paradigm * The channel named "WLs" defines the set of wavelengths * Other channels contain the NIRS time-series measurements. For a given NIRS channel, its name is composed of the pair Source / Detector and the wavelength index. Column Loc(1) contains the coordinates of the source, Loc(2) the coordinates of the associated detector and Loc(3) the coordinates of the middle point between the source and the detector. * The group "NIRS_PROX" indicates that the channel is a close-source measurement. |
* The channel named "STIM1" encodes the stimulation paradigm * Other channels contain the NIRS time-series measurements. For a given NIRS channel, its name is composed of the pair Source / Detector and the wavelength value. Column Loc(1) contains the coordinates of the source, Loc(2) the coordinates of the associated detector. * Each NIRS channel is assigned to the group "NIRS_WL690" or "NIRS_WL830" so specified its wavelength. * The comment "NIRS_PROX" indicates that the channel is a close-source measurement.<<BR>>TODO: keep NIRS_PROX ?? |
Line 130: | Line 147: |
Line 133: | Line 149: |
* NIRS: 96 NIRS channels (2 wavelenghts x 48 Source-Detector pairs) | * NIRS: 96 NIRS channels (2 wavelengths x 48 Source-Detector pairs) |
Line 135: | Line 151: |
* NIRS_WL_DEF: 1 sequence of two values defining the wavelengths (690nm and 830nm) * NIRS_PROXY: 4 NIRS close-distance channels |
|
Line 151: | Line 165: |
Line 155: | Line 168: |
* '''WL1''': contains only the channels corresponding to the 1st wavelength (690 nm here) * '''WL2''': contains only the channels corresponding to the 2nd wavelength (890 nm here) |
* '''NIRS_WL690''': contains only the channels corresponding to the 690nm wavelength * '''NIRS_WL830''': contains only the channels corresponding to the 830nm wavelength * '''NIRS_PROXY''': contains only the proximity channels |
Tutorial: Import and visualize functional NIRS data
|
This tutorial is under construction |
Authors: Thomas Vincent, Zhengchen Cai
The current tutorial assumes that the tutorials 1 to 6 have been performed. Even if they focus on MEG data, they introduce Brainstorm features that are required for this tutorial.
List of prerequisites:
Download
The dataset used in this tutorial is available online.
Go to the Download link page of this website, and download the file: nirs_sample.zip
- Unzip it in a folder that is not in any of the Brainstorm folders
Presentation of the experiment
- Finger tapping task: 10 stimulation blocks of 30 seconds each, with rest periods of ~30 seconds
One subject, one NIRS acquisition run of 12 minutes at 10Hz
- 4 sources and 12 detectors (+ 4 proximity channels) placed above the right motor region
- Two wavelengths: 690nm and 830nm
MRI anatomy 3T from scanner type
Create the data structure
Create a protocol called "TutorialNIRSTORM":
Got to File -> New Protocol
- Use the following setting :
Default anatomy: Use individual anatomy.
Default channel file: Use one channel file per subject (EEG).
In term of sensor configuration, NIRS is very similar to EEG and the placement of optodes may change from subject to the other.
Should we add (EEG or NIRS) in the interface?
Create a subject called "Subject01" (Go to File -> New subject), with the default options
Import anatomy
Import MRI
Make sure you are in the anatomy view of the protocol.
Right-click on "Subject01 -> Import MRI". Select T1_MRI.nii from the NIRS_sample data folder.
This will open the MRI review panel where you have to set the fudicial points (See Import the subject anatomy).
Here are the MRI coordinates of the fudicials used to produce the above figure:
- NAS:
- LPA:
- RPA:
- AC:
- PC:
Import Meshes
The head and white segmentations provided in the NIRS sample data were computed with Brainvisa.
Right-click on "Subject01 -> Import surfaces". From the NIRS sample data folder, select files: head_10000V.mesh, hemi_8003V.mesh and white_8003V.mesh.
You can check the registration between the MRI and the loaded meshes by right-clicking on each mesh element and going to "MRI registration -> Check MRI/Surface registration".
Import NIRS functional data
The functional data used in this tutorial was produced by the Brainsight acquisition software and is available in the NIRS sample folder in S01_Block_FO_LH_Run01.brs. This folder contains the following files:
fiducials.txt: the coordinates of the fudicials (nasion, left ear, right ear).
The positions of the Nasion, LPA and RPA should have been digitized at the same location as the fiducials previously marked on the anatomical MRI. These points will be used by Brainstorm for the registration, hence the consistency between the digitized and marked fiducials is essential for good results.optodes.txt: the coordinates of the optodes (sources and detectors), in the same referential as in fiducials.txt. Note: the actual referential is not relevant here, as the registration will be performed by Brainstorm afterwards.
S01_Block_FO_LH_Run01.nirs: the NIRS data in a HOMer-based format document format.
Note: The fields SrcPos and DetPos will be overwritten to match the given coordinates in "optodes.txt"
To import this data set in Brainstorm:
- Go to the "functional data" view of the protocol.
Right-click on "Subject01 -> Import MEG/EEG/NIRS"
- Select file type "NIRS: Brainsight (.brs)"
Load the file "S01_Block_FO_LH_Run01.nirs" in the NIRS sample folder.
Note: the importation process assumes that the files optodes.txt and fiducials.txt are in the same folder
as the .nirs data file.
Refine registration now? YES
This operation is detailed in the next section
Registration
In the same way as in the tutorial "Channel file / MEG-MRI coregistration", the registration between the MRI and the NIRS is first based on three reference points Nasion, Left and Right ears. It can then be refined with the either the full head shape of the subject or with manual adjustment.
Step 1: Fiducials
The initial registration is based on the three fiducial point that define the Subject Coordinate System (SCS): nasion, left ear, right ear. You have marked these three points in the MRI viewer in the previous part.
- These same three points have also been marked before the acquisition of the NIRS recordings. The person who recorded this subject digitized their positions with a tracking device (here Brainsight). The position of these points are saved in the NIRS datasets (see fiducials.txt).
- When we bring the NIRS recordings into the Brainstorm database, we align them on the MRI using these fiducial points: we match the NAS/LPA/RPA points digitized with Brainsight with the ones we placed in the MRI Viewer.
- This registration method gives approximate results. It can be good enough in some cases, but not always because of the imprecision of the measures. The tracking system is not always very precise, the points are not always easy to identify on the MRI slides, and the very definition of these points does not offer a millimeter precision. All this combined, it is easy to end with an registration error of 1cm or more.
- The quality of the source analysis we will perform later is highly dependent on the quality of the registration between the sensors and the anatomy. If we start with a 1cm error, this error will be propagated everywhere in the analysis.
Step 2: Head shape
We don't have digitized head points for this data set. We should skip this
Step 3: manual adjustment
TODO?
To review this registration, right-click on "" ->
add screenshot
As reference, the following figures show the position of fiducials [blue] (inion and nose tip are extra positions), sources [orange] and detectors [green] as they were digitized by Brainsight:
Review Channel information
The resulting data organization should be:
TODO: update screenshot
This indicates that the data comes from the Brainsight system (BRS) and comprises 97 channels.
To review the content of channels, right-click on "BS channels -> Edit channel file".
TODO: add screenshot of updated channel table
|
Name |
Type |
Group |
Comment |
Loc(1) |
Loc(2) |
Loc(3) |
... |
1 |
TAPPING |
Stim |
|
|
N/A |
N/A |
N/A |
|
2 |
WLs |
NIRS_WL_DEF |
|
|
N/A |
N/A |
N/A |
|
3 |
S1D1WL1 |
NIRS |
NIRS_WL1 |
|
coords S1 |
coords D1 |
coords middle [S1-D1] |
|
4 |
S1D1WL2 |
NIRS |
NIRS_WL2 |
|
coords S1 |
coords D1 |
coords middle [S1-D1] |
|
5 |
S1D2WL1 |
NIRS |
NIRS_WL1 |
|
coords S1 |
coords D2 |
coords middle [S1-D2] |
|
6 |
S1D2WL2 |
NIRS |
NIRS_WL2 |
|
coords S1 |
coords D2 |
coords middle [S1-D2] |
|
7 |
S1P1WL1 |
NIRS |
NIRS_WL1 |
(NIRS_PROX) |
coords S1 |
coords D2 |
coords middle [S1-D2] |
|
8 |
S1P1WL2 |
NIRS |
NIRS_WL2 |
(NIRS_PROX) |
coords S1 |
coords D2 |
coords middle [S1-D2] |
|
- The channel named "STIM1" encodes the stimulation paradigm
- Other channels contain the NIRS time-series measurements. For a given NIRS channel, its name is composed of the pair Source / Detector and the wavelength value. Column Loc(1) contains the coordinates of the source, Loc(2) the coordinates of the associated detector.
- Each NIRS channel is assigned to the group "NIRS_WL690" or "NIRS_WL830" so specified its wavelength.
The comment "NIRS_PROX" indicates that the channel is a close-source measurement.
TODO: keep NIRS_PROX ??
Visualize NIRS signals
Right-clicking on the raw file shows the list of channel types:
- NIRS: 96 NIRS channels (2 wavelengths x 48 Source-Detector pairs)
- STIM: 1 sequence stimulation blocks
Select -> NIRS -> Display time series
It will open a new figure with superimposed channels
add screenshot
Which can also be viewed in butterfly mode
add screenshot
We refer to the tutorial for navigating in these views "Review continuous recordings"
Montage selection
Within the NIRS channel type, the following channel groups are available:
All channels: gathers all NIRS channels
NIRS_WL690: contains only the channels corresponding to the 690nm wavelength
NIRS_WL830: contains only the channels corresponding to the 830nm wavelength
NIRS_PROXY: contains only the proximity channels
Add screenshot