SEEG Time-Frequency Fingerprint Analysis for Epileptogenic Zone Localization

Authors: Yash Shashank Vakilna, Chinmay Chinara, Johnson Hampson, Takfarinas Medani, Raymundo Cassani, John Mosher, Sylvain Baillet, Richard Leahy

This tutorial introduces concepts specific to managing intracranial stereoencephalography (SEEG recordings) within the Brainstorm environment. It guides users through computing time-frequency decomposition maps to identify the epileptogenic zone (EZ) using both ictal and interictal SEEG data. The tutorial is based on a clinical case from the McGovern Medical School at the University of Texas Health Science Center at Houston, Texas, USA.

Please note that this tutorial is intended for users alerady familiar with Brainstorm. It does nto provide detailed explanations of the software's interface or theoretical foundations. For comprehensive introductory material, refer to the Brainstorm introduction tutorials.

NOT FOR CLINICAL USE:
The methods and software implementations presented in this tutorial have not been certified as medical devices. They are intended for research purposes only and should not be used for clinical decision-making.

Contents

  1. Dataset description
    1. License
    2. Clinical description
    3. SEEG recordings
    4. Files
    5. References
  2. Download and installation
  3. Import the anatomy
    1. Pre-implantation MRI
    2. Generate default surfaces using CAT12
    3. Post-implantation CT
  4. Electrode labeling and contact localization
    1. Generate isosurface
    2. Start implantation
    3. Create electrodes and plot contacts manually
  5. Access the recordings
    1. Link the recordings
    2. Import the contacts positions
  6. Display the depth electrodes
    1. 3D figures
    2. MRI Viewer
    3. Panel iEEG
  7. Review recordings
    1. Power spectrum
    2. Add events
  8. Import epochs of interest
    1. Import in database
    2. Bipolar montage
  9. Head modeling
  10. Compute noise covariance matrix
  11. Modeling interictal spikes
    1. Compute inverse model
    2. Display sensor time series
    3. View sources
    4. Atlases and scouts
  12. Modeling ictal wave
  13. Modeling ictal onset with LVFA
    1. Sensor space
    2. Source space
  14. Modeling ictal onset with repetitive spiking
    1. Sensor space
    2. Source space
  15. Edit the contacts positions
  16. Export the contacts position
  17. Additional Documentation
    1. Forum discussions
    2. Related tutorials
  18. Scripting

Dataset description

License

This EEG, MRI, and CT data provided in this tutorial remain the property of the McGovern Medical School at the University of Texas Health Science Center at Houston. Use or distribution of this dataset outside the scope of the Brainstorm tutorials - including for research purposes - is striclty prohibited without prior written consent. For inquiries regarding permissions, please use the Brainstorm user forum.

Clinical description

The dataset featured in this tutorial was recorded at the Epilepsy Monitoring Unit (EMU) of UTHealth Houston. It pertains to a 25-year-old right-handed woman with drug-resistant epilepsy since the age of six. At 15, she underwent a right parietal opercular corticectomy. Despite this intervention, she continued to experience weekly focal aware seizures characterized by a left-hand tingling aura, as well as focal impaired awareness seizures presenting with staring and pouting.

During her EMU admission, intermittent right parietal slowing was observed, and ten habitual seizures were recorded, originating from the C4–P4 region. Magnetic resonance imaging (MRI) revealed bilateral perisylvian polymicrogyria (PMG), pachygyria, right posterior temporal periventricular nodular heterotopia, and post-surgical changes. Magnetoencephalography (MEG) localized discharges to the right superior parietal region adjacent to her previous resection.

SEEG implantation identified two distinct seizure onset patterns: 1) Low-voltage fast activity in the right superior parietal PMG during focal aware seizures; 2) Repetitive spiking in the posterior insular PMG during impaired awareness seizures.

Following a multidisciplinary evaluation, the patient underwent MR-guided laser interstitial thermal therapy (LITT) targeting the right superior parietal and posterior insular PMG. The procedure was uncomplicated, and she remained seizure-free at a one-year follow-up.

SEEG recordings

https://neuroimage.usc.edu/brainstorm/Tutorials/SeizureFingerprinting?action=AttachFile&do=get&target=pmt.png

The recording electrodes used in this dataset are PMT SEEG Depth Electrodes, with the following specifications:

  • Diameter: 0.8 mm
  • Contact length: 2 mm
  • Insulator length: 1.5 mm
  • Distance between the center of two contacts: 3.5 mm
  • Between 8 and 16 contacts on each electrode

Files

tutorial_seizure_fingerprinting/

  • anatomy/: Anatomy data

    • pre_T1.nii.gz: Raw pre-implantation T1 MRI (in NIfTI-1 format),

    • post_CT.nii.gz: Raw post-implantation CT scan (in NIfTI-1 format),

    • cat12: Folder containing precomputed CAT12 head tissue surfaces segmented from the MRI volume above. More details about the files can be found in MRI segmentation using CAT12.

  • recordings/: SEEG recordings

    • Baseline.edf: Raw SEEG baseline recording (in EDF format),

    • ictal_repetitive_spike.edf: Raw SEEG recordings (in EDF format) of a seizure with ictal repetitive spiking,

    • interictal_spike.edf: Raw SEEG recordings (in EDF format) of interictal spikes,

    • LVFA_and_wave.edf: Raw SEEG recordings (in EDF format) of seizure onset showing low-voltage fast activity.

  • Subject01_electrodes_mm.tsv: Position of electrode contacts identied with Brainstorm in world coordinates, relative to the post-implantation CT scan volume. See Electrode labeling and contact localization for more details on this procedure.

References

Further details for this study can be found under the following link: https://zenodo.org/records/14807262

Download and installation

  • Prerequisites:

    • Brainstorm Installation: Ensure you have a working copy of Brainstorm installed on your computer.

    • Familiarity with Brainstorm: This tutorial assumes that you have completed all the Brainstorm introduction tutorials and are comfortable with its interface and basic functionalities.

  • SPM12 (Statistical Parametric Mapping)

    • Purpose: SPM12 is required for:

      • Coregistration between pre-implantation MRI and post-implantation CT volumes.
      • Utilizing tissue segmentation masks to remove extracranial regions from the CT.

    • Installation:

      • MATLAB Users: If you are running Brainstorm within MATLAB, install SPM12 either as a Brainstorm plugin or through a custom installation.

      • Standalone Brainstorm Users: If you are using the standalone compiled version of Brainstorm, SPM12 functionalities are included in the executable, and no additional installation is necessary.

  • OpenMEEG: To compute the forward head model the OpenMEEG Brainstorm plugin is required.

  • Download the dataset:

    • Go to the Brainstorm Download page

    • Download the file: tutorial_seizure_fingerprinting.zip.

    • Unzip it into a folder that is not located in any Brainstorm directories (i.e., not in the Brainstorm program folder or database folder).
  • Brainstorm Setup:

    1. Start Brainstorm.
    2. From the top menu, select: File > Create new protocol.

    3. Name the new protocol: TutorialSeizureFingerprinting

    4. Set the following options:
      "No, use individual anatomy",
      "No, use one channel file per acquisition run".

Import the anatomy

Pre-implantation MRI

  • In the Brainstorm database view, right-click on the TutorialSeizureFingerprinting folder → select New subject → name the subject: Subject01.

  • Keep the default anatomy options defined when the protocol was created.
  • Switch to the Anatomy view (using the tab above the database explorer).

  • Right-click on the subject node (Subject01) → select Import MRI.

    • Set the file format to: MRI: NIfTI-1 (*.nii;*.nii.gz)
    • Select the file: tutorial_seizure_fingerprinting/anatomy/pre_T1.nii.gz
  • The MRI viewer loads with the MRI where we now need to set the required fiducial points - Nasion (NAS), Left Preauricular (LPA) and Right Preauricular (RPA) - that help define the Brainstorm's Subject Coordinate System (SCS).

  • For each point, click the iconViewScoutInMri.gif , enter the MRI coordinates as under and click Set button to set the point on the MRI.

    • NAS: 104, 207, 85

      1_nas.png

    • LPA: 26, 113, 78

      1_lpa.png

    • RPA: 176, 113, 78

      1_rpa.png

  • Click Save to close the MRI viewer.

  • A new node named pre_T1 will be created under the subject in the database.

    2_import_pre_T1.png

While this is not applicable to the current dataset, some NIfTI MRI files may include a transformation matrix in their header. In such cases, a pop-up window may appear asking: Do you want to apply the transformation to the MRI file? Selecting Yes will apply the transformation and reorient the MRI into Brainstorm's standard orientation, allowing you to view the coronal, sagittal, and axial planes correctly.

Generate default surfaces using CAT12

We recommend generating cortical surfaces with CAT12, especially if you are interested in a realistic representation of the patient's cortical folding in 3D. Follow the CAT12 tutorial to generate the surfaces as under.

14_seg_cat12.png

These surfaces will be used later, in the computation of the epileptogenicity maps. Read the section Importing realistic surfaces for information on how to use realistic surfaces from BrainVISA or FreeSurfer.

Segmentation using CAT12 can take around 1 hour depending on your system. To save time, we provide the precomputed CAT12 segmented surfaces generated using the MRI above as part of the tutorial dataset (tutorial_seizure_fingerprinting/cat12). To import them just right click on the Subject01 > Import anatomy folder and select the precomputed CAT12 folder above. Set vertices as 15000 and the same fiducial points as in the section above. More details can be found in the CAT12 tutorial.

Post-implantation CT

The pre-implantation MRI imported above will serve as the anatomical reference for this subject.

We will now import a second scan acquired after SEEG electrode implantation, in which the electrode contacts are visible. In this dataset, the post-implantation volume is a CT scan, where the SEEG contacts appear as bright (hypersignal) spots.

  • Right-click on the subject node (Subject01) → select Import CT.

  • In the file selection dialog, choose: tutorial_seizure_fingerprinting/anatomy/post_CT.nii.gz
  • For coregistration, select the option: SPM

    • For more information about this procedure, see the Volume coregistration section

  • When prompted to reslice the CT volume, choose Yes. * This ensures that the CT volume is resampled to match the voxel dimensions of the MRI. 3_coreg_ct.png

  • For skull stripping, again choose SPM. * This uses the SPM Tissue Segmentation algorithm to generate a binary mask that retains only the brain region in the CT volume, removing extracranial structures.


4_coreg_clean_ct.png

You can also perform skull stripping using BrainSuite's Brain Surface Extractor. Installation steps are detailed in the BrainSuite for Brainstorm tutorial.

  • The MRI viewer will open automatically, displaying the post-implantation CT volume as a colored overlay on top of the previously imported MRI. * Use the Surface tab, under the Data options section, to adjust the transparency and amplitude threshold of the CT layer.

    • You can also modify the colormap by right-clicking on the figure and selecting from the popup menu.

    Use this interactive display to verify the accuracy of the coregistration:All anatomical structures—including scalp, skull, and brain—should align well between the CT and MRI volumes. 5_coreg_overlay.png

  • A new node named post_CT_spm_reslice_masked_spm is created in the database. The postfix _spm_reslice_masked_spm reflects the sequence of processing steps applied to the CT volume:

    • spm: Coregistration using SPM

    • reslice: Resampling to match the MRI voxel grid

    • masked_spm: Skull stripping using the SPM tissue segmentation mask

  • To view the full processing history of this file:
    • Right-click on post_CT_spm_reslice_masked_spm → File > View file history 6_import_post_CT.png

  • To open and inspect the CT volume alone:
    • Right-click on post_CT_spm_reslice_masked_spm → Display > MRI Viewer 7_view_post_CT.png

Electrode labeling and contact localization

If you do not have any recordings in the database, Brainstorm allows to creation and annotation of intracranial electrodes and contacts. Users can also then export these as a text file with all the positions that can be used in Brainstorm or any other program.

Generate isosurface

This creates a thresholded mesh from the CT by separating the contacts out from rest of the CT. This aids the user towards localization of the electrodes and its contacts more accurately.

  • The first thing required is to define a good threshold (which we call isoValue) that will separate out the contacts from the rest of the CT. Just open the CT file (by double clicking on it), click on the MIP: Functional in the MRI Viewer, use the Data Options > Amplitude slider in the Surface tab to browse through the threshold, and once you are satisfied with getting a good separation of the contacts, hover on the slider to get the desired value and keep a note of it (to the nearest integer). In this case the value is 2276.

    8_choose_isovalue.png

  • Right click on post_CT_spm_reslice_masked_spm> CT segmentation > Generate SEEG/ECoG isosurface.

    9_isosurface_menu.png

  • This will bring the Generate isosurface window. This window shows 4 values: the Background level, White level, Max Intensity and the suggested Set isoValue, all of them given in the Hounsfield Unit (HU) scale. The first 3 values are calculated automatically from the histogram of the CT and are displayed for reference. The editable isoValue field shows an estimated best guess based on mean of White Level and Max Intensity. Since we got a better value in step-1 above, set the value to 2276 and press OK.

    10_isosurface_popup.png

  • An isosurface is generated showing the contact as blobs overlayed on the 3D MRI slices. The Thresh slider under Surface options can be further used to fine tune and regenerate mesh with different isoValues.

    11_isosurface_display.png

Start implantation

  • Right click on Subject01, and choose SEEG/ECOG implantation.

  • The SEEG/ECOG implantation menu pops to choose which modalities you want to use for doing your implantation with.

    12_implant_menu.png

MRI: MRI viewer loads up with MRI volume only.
CT: MRI viewer loads up with CT volume only.
MRI+CT: MRI viewer loads up with the CT overlayed on the MRI.
MRI+CT+IsoSurf: MRI viewer loads up with the CT overlayed on the MRI. 3D figure loads up with the isosurface and 3D MRI slices.

  • Choose MRI+CT+IsoSurf. This takes you to the functional tab. Subject01 > Implantation > SEEG/ECOG (0) channel gets created. All expected figures open up. Panel iEEG loads up in the panel viewer. Move around the 3D slices to get a clear view of the contacts so that they can be clicked on.

    13_implant_setup.png

  • To know more about the iEEG panel and its features go to Epileptogenicity tutorial.

Create electrodes and plot contacts manually

Before we start the implantation a prior knowledge of the implantation scheme is required in order to have the correct labels of the various electrodes used. One way here is to have a look at the recordings file and get a knowledge of that. Brainstorm matches the channel names to that of the recordings while importing the positions to them.

  • After performing steps above, we will have the Panel iEEG along with the MRI Viewer and 3D figure open. We will be working on the electrode marked below.

    30_electrode_POP_labelled.png

  • On Panel iEEG Click on the + (Add new electrode). This opens up the Add electrode window. For this e.g. enter POP (it is one of the electrodes in the recordings available in this tutorial data) and press OK.

    31_add_electrode_ask.png

  • This creates an electrode POP in selected state, and at the bottom the Electrode configuration section of the panel becomes active. Select the following:

    • Type: SEEG

    • Model: Choose PMT 2102-16-093/2102-16-103 from the drop down list. This will automatically set the other parameters in the section. More details for these parameters can be found in the advanced section here.

      32_elec_pop_model.png

  • Set tip: Choose the location of the electrode's contact that is deepest in the brain. While we can use the MRI Viewer to set this location (as mentioned here), but to get a more accurate location we will leverage the 3D isosurface as described below.

    • As seen in the first figure in this section, the tip contact blob is not well separated form its adjacent contact. As mentioned in the Generate isosurface section, switch to Surface tab, use the Thresh slider to adjust the isovalue to approximately 3100 and a readjusted isosurface will be generated that separates out the tip area contacts.

      33_elec_pop_tip_separate.png

    • Switch back to the iEEG tab, click the iconScoutNew.gif button (shortcut: Ctrl+P) to activate surface point selection mode.

    • Click on the iconGood.gif button to activate selecting centroid of the candidate contact blob in the isosurface.

    • Choose the tip contact in the readjusted 3D isosurface and this should plot a yellow crosshair marker point on the center of the blob and also update the MRI Viewer's crosshair. At the bottom in click Set tip and the button turns green indicating that the tip has been set. This point in 3D is at the centroid of the blob which gives a more accurate location of the contact compared to the same if chosen from the MRI.

      34_elec_pop_tip.png

  • Set skull entry: Choose the point in the 3D isosurface which is going to be set as the skull entry. This point can be any of the contacts other than the tip preferably closer to the skull so that we get an orientation of the electrode.

    • This should plot a yellow crosshair marker point on the blob and also update the MRI Viewer's crosshair.

      35_elec_pop_entry1.png

    • At the bottom of iEEG tab, click Set skull entry and the button turns green indicating that the entry point has been set. All the figures get updated with the an electrode based on the above configuration. The properties used for setting the position of the contacts are the contact spacing, the tip of the electrode and the entry point in the skull. Contact #i is placed along the electrode at (i-1)*contact_spacing millimeters from the tip of the electrode.

      35_elec_pop_entry2.png

  • Click on Contacts > Save Modifications to update the channel information in the database.

    36_elec_pop_save.png

  • Repeat the steps for creating implantations for all the other electrodes one by one and save the modifications. Each time you can see the channel file SEEG/ECOG being updated.

  • When you are done with everything, close all the figures and a prompt appears asking to save the changes. Just click Yes for everything. If all localized properly, the Implantation folder should now have channel file that defines the locations of all the 230 contacts.

  • To make this tutorial easier to reproduce and follow, we also distribute the positions of the contacts (that were localized using the steps above) exported as a .tsv file: tutorial_seizure_fingerprinting/Subject01_electrodes_mm.tsv. You can directly import them into the Implantation folder:

    • Right click on Implantation > Import channel file, choose type as EEG: BIDS electrodes.tsv, subject space mm (*.tsv), browse and select the .tsv file, click Open

    • Set the scaling factor as 1 (the positions in this .tsv file are in millimeters, the expected unit for this file format is also millimeters, there is no adjustment to make here)

    • Set the import reference MRI as post_CT_spm_reslice_masked_spm (as the implantation was done on it) and press OK.

    • Select Yes to replace the existing channel file and all the 230 contacts are updated in the channel. We will use this to link to the recordings in the section below.

      36_elec_pop_save1.png

In some cases, additional correction of the contacts may be required. To edit the individual contacts refer to the Edit the contacts positions advanced section.

Access the recordings

Link the recordings

  • Switch to the "functional data" view (2nd button, on top of the database explorer).
  • Right-click on the subject folder > Review raw file:

    • Select the file format: EEG: EDF/EDF+

    • Select all the recordings: tutorial_seizure_fingerprinting/recordings/*.edf

      15_import_link.png

    • The selected recordings get added to the database.

      15_import_link2.png

  • The new files Link to raw file let you access directly the contents of the original SEEG files. The menu Review raw file does not actually copy any data to the database. More details.

Import the contacts positions

In order to generate epileptogenicity maps, we need accurate 3D positions for the contacts of the depth electrodes. Placing the contacts requires a good understanding of the implantation scheme reported by the neurosurgeon, and some skills in reading MRI scans.

  • The channel file "EDF channels" contain the name of the channels, but not their positions. We need to import or edit separately the positions of the SEEG contacts.
  • Click on the [+] next to the four folders, select all the channel files simultaneously.

  • Right-click one channel file > Add EEG positions > From other studies > Implantation

    83_import_pos_file_implantation.png

  • At the end, you get a report indicating how many channels from the SEEG recordings were attributed a new 3D position. The channels are matched by name: the position file you import must include the labels of the channels and they must be named exactly in the the same way as in your recordings.

    20_import_pos_report.png

  • For EDF Channels under LVFA_and_wave and interictal_spike, there were 12 channels not found. The type of the channels for which a position was not found is set to EEG_NO_LOC, in order to ignore them when processing the SEEG data. In this example dataset, the channels numbered 245 to 255 and 262 are not found as they are not SEEG contacts.

  • For all the EDF Channels, mark the channel MPS16 as SEEG_NO_LOC because if not marked, when we compute the forward head model using BEM surfaces it says that MPS16 lies outside the BEM layer. Marking it excludes it from any future computations.

  • You should always validate that the type of all the channels has been detected correctly. Check also that the names are correct and using the same convention for all the contact of a given electrode. These are entered manually, and typing errors are frequent. Right-click on a channel file > Edit channel file.

    16_edit_channel.png

  • To edit one channel, double-click on the text to modify. To edit multiple channels, select them all and right-click > Set channel group/type. The column Group corresponds to the name of the depth electrode. It is detected based on the channel type and name. If you include as SEEG a channel that detected as something else or rename a channel, you would need to manually update the channel name.

  • If you don't have the positions for the SEEG contacts, or if they don't look correctly aligned, see the section Edit the contacts positions on how to tackle it.

  • To make this tutorial easier to reproduce and follow, we also distribute the positions of the contacts (that were localized as per the section above) exported as a .tsv file (tutorial_seizure_fingerprinting/Subject01_electrodes_mm.tsv). To import the contacts position from that refer to Epileptogenicity tutorial.

Display the depth electrodes

3D figures

  • Right-click on the channel file > Display sensors and explore all the available options.

    23_display_menu.png

  • You can render the SEEG depth electrodes in 3D together with the subject anatomy: surfaces, pre- or post-implantation volumes. You can add more anatomy elements to the figure with the button Add a surface ( iconSurfaceAdd.gif ) at the top-right of the Surface tab. For more help: Display the anatomy.

    24_display_3d.png

  • Click on a contact to select it, right-click on it to get its name.

    25_display_selectchan.png

MRI Viewer

  • You can also display the contacts in the MRI viewer, on top of the the pre- or post-implantation volumes. By default, the electrode is displayed in a slice if there is a SEEG contact associated to it in the slice.

    26_display_mri.png

  • To display all the electrodes, select the option "MIP: Functional". For a glass-brain view, select at the same time the option "MIP: Anatomy".

    27_display_mri_mip.png

  • Zoom in/out with the buttons or the associated shortcuts (Ctrl+Scroll or +/-) and explore the volume with (Shift+)x/y/z. Additional display options are available in the popup menu for this figure. All the shortcuts are listed in this tutorial.

Panel iEEG

  • When opening SEEG/ECOG recordings, the panel iEEG is added to the Brainstorm window. You can use it to edit the display properties of the depth electrodes. More details about the iEEG Panel can be found in the Epileptogenicity tutorial.

    29_panel_ieeg.png

To know more about ways to display the SEEG recordings in Brainstorm refer to the Epileptogenicity tutorial.

Review recordings

Power spectrum

We recommend that you start your data analysis with a power spectral density estimation of the recordings to check the quality of sensor recording. This is described in more details in the Power spectrum tutorial.

  • In Process1, select all the continuous files (Link to raw files or folders).

    48_psd_process.png

  • Double-click on the PSD files to display them. Some channels have noise levels that are obviously higher than the others and should therefore be considered as suspicious.
    • In the Baseline PSD, peaks related with the power lines: 60Hz, 180Hz, 300Hz, 420Hz, 540Hz, 660Hz, 780Hz and 900Hz can be seen below.

      49_psd_result1.png

    • Applying the notch filter process can be used to remove these frequencies. The interictal spike, ictal repetitive spike and LVFA and wave are subsets of the Baseline recordings which have all the 60Hz+harmonics removed and it can clearly be seen from their respective PSDs in the figure below.

      49_psd_result2.png

Add events

We need to mark seizure onset event for the ictal and LVFA and wave recordings and spike event for interictal recording. There are events already available in recordings, that were marked for clinical use, to jump quickly to the page of interest. More details can be found in the tutorial Event Markers.

  • For LVFA and wave, we will create a new event sEEG Onset at around 15s (center of the 30s recording extract).

    51_mark_onset_law.png

  • For ictal repetitive spike, we will create a new event sEEG Onset at around 15s (center of the 30s recording extract).

    50_mark_onset_irs.png

  • For interictal spike, we will create a new event Interictal spike at around 5s (center of the 10s recording extract).

    52_mark_spike_is.png

Import epochs of interest

At this point of the analysis, we are still looking at the original files, no SEEG data was copied to the database. The montages are saved in the Brainstorm preferences, the new events are saved in the links of the database.

We are now going to import the three segment of recordings i.e. LVFA and wave , ictal repetitive spike and interictal spike which are a subset of the Baseline recording.

Import in database

  • Right click on LVFA_and_wave > Link to raw file > Import in database.

    • Time window: All (0 to 30.0495)
    • Split in time blocks: Disabled
    • Use events: Enabled, select sEEG Onset

    • Epoch time: [-15000, +15000] ms (imports -15s to 15s around the event sEEG Onset)

    • Remove DC offset: Enabled. More details can be found here.

    • Resample: Disabled
    • Create a separate folder for each event type: Disabled
    • Click Import.

      53_import_onset.png

  • Repeat the same steps above for importing ictal repetitive spike into the database.

  • Repeat the same steps above for importing interictal spike into the database with the modification in the following options:

    • Time window: All (0 to 10.0495)
    • Use events: Enabled, select Interictal spike

    • Epoch time: [-5000, +5000] ms (imports -5s to 5s around the event Interictal spike)

  • At the end, you should have three new folders LVFA and wave , ictal repetitive spike and interictal spike, the same name as the original raw files, but without the tag RAW on top. These new folders contain copies of the SEEG recordings, if you delete these folders from the database explorer, you lose the recordings they contain.

  • The imported epochs are saved with a new timing: for LVFA and wave and ictal repetitive spike, the reference time t=0s is now the event sEEG Onset and for Interictal spike, the reference time t=0s is now the event Interictal spike, which has been removed from the list. You can still see the other marker timings adjusted accordingly.

    54_import_database.png

Bipolar montage

We will run the rest of the analysis using a bipolar montage (bipolar-2). The montage selected in the Record tab is for visualization only, most processes ignore this selection and work only on the original common-referential montage. To compute bipolar montage on time series, we need to explicitly apply the montage to the recordings. More details can be found in tutorials Montage editor and Epileptogenicity.

  • In Process1, drag and drop all the imported recordings (either the folders or the files).

  • Run the process Standardize > Apply montage

    • Montage name: Subject01: SEEG (bipolar 2)[tmp]

    • Create new folders: Enabled

      55_import_montage.png

  • This process rewrites the channel files and data files in the selected folders. The position associated with a bipolar channel in the channel file is the middle of the segment between the two contacts (e.g. AH1-AH2 is placed half-way between AH1 and AH2).

    56_import_montage_chan.png

Head modeling

The forward models depend on the subject's anatomy, including head size and geometry, tissue conductivity, the computational method, and sensor characteristics. In this section, we will use the Boundary Element Method (BEM) approach available in Brainstorm for constructing the head model for sEEG.

  • We will first generate the BEM head surfaces from the MRI. More details can be found in OpenMEEG BEM tutorial. This will generate three surfaces head, outer skull and inner skull estimated from the head mask and the cortex obtained from the segmentation. The BEM surfaces will be used for the BEM forward computation below.

    57_head_modeling.png

  • We will then compute the forward head model using the OpenMEEG BEM method. Switch to functional tab, right-click on the interictal_spike > EDF channels > Compute head model.

    • Source space: Cortex surface

    • Forward modelling methods: SEEG: OpenMEEG BEM

    • Use only Brain in BEM layers and conductivities (corresponds to bem_innerskull surface) as other surfaces do not matter for SEEG.

    • Use default OpenMEEG options.

      58_headmodeller_openmeeg.png

  • A new head model will be added to the folder.

    59_headmodeller_final.png

  • Right click on the head model file > Copy to other folders. Since the other folders contain data collected from the same subject using the same set of electrodes, we do not need to recompute the head model for each of them separately.

  • View leadfield vectors:

    • Right click on the head model file > View SEEG leadfield vectors

    • Select reference MC2 and click OK

    • Click on the figure and press E to display the electrodes

    • Make sure scouts are unselected (Scout tab > ALL and SEL unselected)

    • Surface tab: transparency = 90 and press Shift+Up arrow till the arrows are visible. Press Up/down to change the Reference electrode, Right/Left to change the target. Close all figures once done.

      60_leadfield_vector.png

Compute noise covariance matrix

  • We will compute the noise covariance matrix for the Baseline recording as per the tutorial Noise covariance.

  • Right click on the Baseline (RAW) > Link to raw file > Noise covariance > Compute from recordings . Keep the default values and click OK.

    61_noise_covariance.png

  • Noise covariance node gets added to the database.

    61_noise_covariance2.png

  • Right click on the Noise covariance and Copy to other folders.

Modeling interictal spikes

Compute inverse model

  • We will compute the inverse model for the interictal_spike recording. For more details refer to the tutorials Source estimation and Volume source estimation.

  • Expand the interictal_spike folder, right click on OpenMEEG BEM > Compute sources [2018].

    • Method: Minimum norm imaging

    • Measure: sLORETA

    • Source model: Dipole orientations: Constrained: Normal to cortex

    • Noise covariance regularization: Diagonal noise covariance

    • Regularization parameter: Signal-to-noise ratio: 3.00

    • Output mode: Inverse kernel only
    • Sensors: SEEG. Click OK.

      62_inverse_model1.png

  • Two files get added to database. To learn about inversion kernel and LINK files in database refer to this section.

    62_inverse_model2.png

Display sensor time series

  • Display time series

    • Right-click on recording Interictal spike > SEEG > Display time series

    • On the Record tab, select montage SPS (bipolar 2)

    • Select the first peak of SPS10-SPS11 (Time 0.041s).

  • Display 2D layout of the spike

    • Right-click on recording Interictal spike > SEEG > 2D Layout

    • Click [...] on the corner and set[-500, 500] as the time window. Doing this will enable visualizing 1s of data across all the sensors giving a more clear sense of where the different spikes are.

      63_disp_ts_interictal.png

View sources

  • Display on cortex

    • Right click on sLORETA (LINK) > Cortical activations > Display on cortex

    • Show sensors: Ctrl+L (electrodes)

    • Set colormap: Colorbar > Colormap:Sources > Permanent menu, select Maximum: Global, Contrast -0, Brightness 0

    • Switch to Surface tab: Amplitude 26%, Min size 13

      64_view_inv_model_cortex.png

  • Display on 3D MRI viewer

    • Right click on sLORETA (LINK) > Cortical activations > Display on MRI (3D)

    • Show sensors: Ctrl+L (electrodes)

    • Press M to go to voxel with maximum intensity

      65_view_inv_model_mri3d.png

  • Display on MRI viewer

    • Right click on sLORETA (LINK) > Cortical activations > Display on MRI (MRI Viewer)

    • Turn on MIP: Functional

    • Switch to Surface tab, Amplitude: 56%, and press M to select voxel with maximum intensity

      66_view_inv_model_mri.png

Atlases and scouts

  • Display sources on the cortical surface
    • Right click on sLORETA (LINK) > Cortical activations > Display on Cortex

    • In the Scout tab, use the drop box to select Desikan-Killiany and click on ALL. This atlas is provided by default in Brainstorm. Ctrl+L to show all electrodes.

      67_atlas_dk.png

  • Since all the electrodes in the data are implanted on the right hemisphere of the brain, it is better to edit this atlas to only have scouts defined for the right region and remove the rest. Also we can subdivide the atlas to smaller scout regions to have smaller ROIs that will help in having better and more focused time-frequency epileptogenic maps later in the tutorial.
    • In Scout tab, select all the scouts in the right hemisphere and then create a new atlas from the selected scouts by Atlas > New atlas > Copy selected scouts. It will create a new atlas named Desikan-Killiany_02.

    • Atlas > Subdivide atlas > Area > Area of the sub-regions: 5 (cm sq.). A total of 176 scouts will be created with smaller and more focussed ROI.

      68_atlas_dk_176.png

  • To know more about scouts in Brainstorm refer to the tutorial Scouts.

Modeling ictal wave

Switch to the folder LVFA_and_wave (not the RAW folder) and repeat the steps to compute inverse model as per the section above and study the sensor time series and inverse modeling results.

69_disp_ts_wave.png

70_view_inv_model_wave.png

Modeling ictal onset with LVFA

Sensor space

Compute time-frequency decomposition

  • Navigate and expand LVFA_and_wave_bipolar_2 folder

  • Delete any previous recordings in the Process 1 tab below

  • Drag-and-drop recording file sEEG onset (#1) | bipolar 2 in Process 1, click [RUN]

    71_time_freq_decomp_lvfa1.png

  • Add the process: Frequency > Time-frequency (Morlet wavelets)

    • Sensor type: SEEG

    • Select Spectral flattening: Multiply output power values by frequency

    • Click Edit...

    • Frequency definition: Log (start:N:stop), 1:25:100

    • Central Frequency: 1 Hz, Time resolution (FWHM): 6s. Click OK and Run.

      71_time_freq_decomp_lvfa2.png

  • A new node Power,1-100Hz (SEEG) | multiply gets added to the database.

    71_time_freq_decomp_lvfa3.png

  • For more details go through the tutorial Time-frequency.

View time-frequency maps

  • Right click sEEG onset (#1) | bipolar 2 > Power,1-100Hz (SEEG) | multiply > All channels

  • Click on Log(Power) to bring out the essential features in the maps.

  • Click on Smooth display to apply a Gaussian kernel to the map so that the underlying pattern becomes clearer for viewing.

  • Click on SPS8-SPS9

  • Set colormap: right-click on Colorbar > Colormap: Timefreq > Permanent menu, Turn-off [Absolute Value](if on), Maximum: Local, Contrast 49 Brightness -65

  • Right-click on the colored time-frequency plot > Power Spectrum, Time Series

    72_time_freq_map_lvfa.png

  • The red marked area above is the high frequency activity. The bottom right area contains the pre-ictal spikes that is signature of seizure fingerprinting.

Source space

Extract scout time series

  • We are going to now extract a single time-series for each of these scouts that best defines it.
  • Switch to the folder LVFA_and_wave (not the RAW folder).

  • Drag-and-drop sLORETA: SEEG(Constr) 2018 (LINK) in Process 1, click [RUN]

    73_scout_time_series_lvfa1.png

  • Add the process: Extract > Scout time series

    • Select Desikan-Killiany [182].

    • Select scouts: Press Ctrl+A to select all the scouts in the box.

    • Select Scout function: PCA

    73_scout_time_series_lvfa2.png

  • A new matrix file sEEG onset (#1) | 182 scouts gets added to the database.

    73_scout_time_series_lvfa3.png

  • Right click on matrix file sEEG onset (#1) | 182 scouts > Display as time series.

    75_scout_time_series_lvfa2.png

Compute time-frequency decomposition

  • Drag-and-drop matrix file sEEG onset (#1) | 182 scouts in Process 1, click [RUN]

  • Rest of the steps are the same as the corresponding earlier section in sensor space.

    74_time_freq_decomp_lvfa2.png

View time-frequency maps

  • Right click on matrix file sEEG onset (#1) | 182 scouts > Power,1-100Hz | multiply > Time-freq: All matrices

  • Right click on matrix file sEEG onset (#1) | 182 scouts > Power,1-100Hz | multiply > Time-freq: One matrix. Set selected data as postcentral R.3.

  • Click on Log(Power), Smooth display.

  • Set colormap: right-click on Colorbar > Colormap: Timefreq > Permanent menu, Turn-off [Absolute Value](if on), Maximum: Local, Contrast 52 Brightness -63

  • Right-click on the colored time-frequency plot > Power Spectrum, Time Series

    76_time_freq_map_lvfa2.png

  • The red marked area above is the high frequency activity. The bottom right area contains the pre-ictal spikes that is signature of seizure fingerprinting. We can say that this patch of cortex postcentral R.3 was most associated with the LVFA pattern.

Modeling ictal onset with repetitive spiking

Sensor space

Display time-series

  • Expand the folder ictal_repetitive_spike_bipolar_2

  • Right click on sEEG onset (#1) | bipolar 2 > Display time series

  • Change Montage to PIN > PIN (orig)

    77_time_series_ictal.png

Compute time-frequency decomposition

Same as above sections. Only one change, set sensor type: PIN5-PIN6 for Time-frequency (Morlet wavelets) process.

78_time_freq_decomp_ictal.png

View time-frequency maps

  • Right click on file sEEG onset (#1) | bipolar 2 > Power,1-100Hz (PIN5-PIN6) | multiply > One channel. Set selected data as postcentral R.3.

  • Click on Log(Power), Smooth display.

  • Set colormap: right-click on Colorbar > Colormap: Timefreq > Permanent menu, Maximum: Custom [-18.5, -8], Contrast 23 Brightness -60

    79_time_freq_map_ictal.png

  • The high frequency activity on the right is due to the rhythmic activity seen in the time series for PIN5-PIN6. On analyzing the time-frequency map, this activity is localized between 5Hz and 55Hz. So we need filter this frequency range so that our results are more focused on the rhythmic activity.

Source space

Compute inverse model

  • Switch to the folder ictal_repetitive_spike

  • Repeat the steps as in the previous section.

    80_inverse_model_ictal.png

View sources

  • Right-click on sEEG onset (#1) > SEEG > Display time series.

  • Change Montage to PIN(orig)

  • Set frequency filter: High-pass: 5Hz, Low-pass: 55Hz

  • Display sources on MRI viewer

    • Right-click on sLORETA: SEEG(Constr) 2018 (LINK) > Cortical activations > Display on MRI (MRI Viewer)

    • Set colormap: Right Click on Colorbar > Colormap: Sources > Permanent Menu, Maximum: Custom [0, 2]

    • Click on Surface tab, set Amplitude 33%

      81_inverse_model_res_ictal.png

  • The peak of the rhythmic activity localized on the patch of the cortex as seen in the MRI Viewer above.

Advanced

Edit the contacts positions

The trajectory of electrode while implantation may not always follow a straight line as there could be bending introduced when the neurosurgeon inserts the electrode. In such cases we need to move these contacts to more appropriate positions.

  • For this section we will consider one such electrode from our dataset above which is marked below. Switch to anatomy tab, open the isosurface file under Subject01 and using the Thresh slider in the Surface tab set the isoValue to approximately 2280.

    37_edit_cont_SPM.png

  • This is a complex case where:
    • The tip is not well separated from its adjacent contact.
    • One of the contacts in the middle can be seen joined to another electrode's contact.
  • Play with the Thresh slider under Surface tab to get a good threshold that separates them out.

  • As per the sections Start implantation and Create electrodes and plot contacts manually above, create an SEEG electrode named SPM with model PMT 2102-16-091/2102-16-101. Switch to Surface tab first and change the isosurface threshold to approximately 2680 to get a clean tip for marking and then switch back to iEEG tab to do the implantation.

  • Set the isosurface threshold back to approximately 2280 for clear view of the 3D blobs. Select the 3D figure and toggle between the electrode ( iconSeegDepth.gif ) and sphere ( iconSeegSphere.gif ) modes to get the figures as under using buttons in iEEG panel. Keep it in the sphere mode for better visibility. The contacts definitely need to be corrected and moved to their right positions.

    38_edit_cont_SPM.png

  • Display the contact labels in 3D figure by right clicking Channels > Display labels. It can be seen that the contacts SPM2-SPM16 are incorrect. Let us first correct contact SPM2.

    39_edit_cont_SPM.png

  • Switch to Surface tab, set the isosurface threshold back to approximately 2680 for separating out the tip and its adjacent contact blob (SPM2). Since the isosurface blobs are the correct ones, we can use them as ground truth guide to correct the contacts. Switch to iEEG tab, click the iconScoutNew.gif button (shortcut: Ctrl+P; to turn on surface point selection), click the iconGood.gif button (to turn on centroid selection in surface) and click the correct 3D blob. That places a yellow crosshair on the blob and updates the MRI Viewer crosshair as well.

    40_edit_cont_SPM.png

  • Without clicking anywhere else, move your cursor to the MRI Viewer, right click and go to Electrodes > Set electrode position (or press Ctrl+S). From the Set electrode position window choose SPM2 and press OK. This will update the position of SPM2 only in the MRI Viewer.

    41_edit_cont_SPM.png

  • Click on Save and it closes all the windows and updates the channel file and number of channels in the database explorer.

  • Right click on Subject01 > SEEG/ECOG implantation. Click Continue for working on the existing implantation. Choose MRI+CT+IsoSurf to show all the figures. Switch to Surface tab, set the isosurface threshold back to approximately 2280 for clear view of the 3D blobs. Select the 3D figure and in the Panel iEEG, choose the sphere ( iconSeegSphere.gif ) mode for display. You will now see the updated contact in the 3D figure as well.

    42_edit_cont_SPM.png

  • Follow the above steps to update all the remaining contacts as required. Unfortunately, Brainstorm currently does not have a way to handle curved electrodes display yet: if you move the contacts, the electrode remains represented as a straight line. This is a display issue only, which has no impact on any computation, but we hope to improve it at some point.

    43_edit_cont_SPM.png

  • We have a functionality called line fitting that can help better view the trajectory in the 3D figure with sphere ( iconSeegSphere.gif ) display mode. Choose the electrode and click Contacts > Show/Hide line fit through contacts.

    44_edit_cont_SPM.png

  • You can also edit the position of a contact directly in the MRI Viewer by clicking on its dot in one of the slice and moving it around. To do it you need to open the MRI Viewer in edit mode by right clicking on the channel file > MRI registration > Edit ... (MRI Viewer:...). Modifications are not saved immediately to the database and can be cancelled when you close the window.

  • You can also use the Add contact and Remove contacts feature in Brainstorm to edit the contacts.

    • Add contact can be done in the following ways:

      • Right click SEEG channel > Display sensors (SEEG: 3D MRI Viewer) > Surface tab (add isosurface) > Select electrode in panel iEEG > Turn on Select Surface Point > Select a location on the isosurface > click Contacts (menu) > Add SEEG contact in iEEG panel or press shortcut key S

      • Right click SEEG channel > Display sensors (SEEG: 3D MRI Viewer) > Surface tab (add isosurface) > Select electrode in panel iEEG > Turn on Select Surface Point > Select a location on the isosurface > Right click Channels > Add SEEG contact or press shortcut key S

      • Right click SEEG channel > Display sensors (SEEG: MRI Viewer) > Select electrode in panel iEEG > Set crosshair at a location in MRI Viewer > click Contacts (menu) > Add SEEG contact in iEEG panel or press shortcut key S

      • Right click SEEG channel > Display sensors (SEEG: MRI Viewer) > Select electrode in panel iEEG > Set crosshair at a location in MRI Viewer > Right click Electrodes> Add SEEG contact or press shortcut key S

    • Remove contacts can be done in the following ways:

      • Select contacts in panel iEEG > press Delete or Backspace

      • Select contacts in panel iEEG > click Contacts (menu) > Remove SEEG contacts

      • Select the contact in 3D figure > press Delete or Backspace

      • Select the contact in 3D figure > right click Channels > Remove contact

        82_add_remove_contacts.png

    • The numbering of the contacts is automatically maintained in ascending order from tip to skull entry.
    • If user deletes all the contacts then then the number of contacts in this case goes down to 0 since all the contacts were deleted. It comes to a state like starting an SEEG electrode implantation from scratch but in this case the number of contacts need to be updated to the desired.

Advanced

Export the contacts position

You can export the contacts created in Brainstorm as a text file to be used later in Brainstorm or in an external software.

  • Right click on the Implantation > SEEG/ECOG channel file, click File > Export to file, choose type as EEG: BIDS electrodes.tsv, subject space mm (*.tsv), set file name as Subject_electrodes_mm.tsv click Save, set the export reference MRI as post_CT_spm_reslice_masked_spm (as the implantation was done on it) and press OK.

    45_export_contacts.png

  • This exports the positions in the file in world coordinates.

Additional Documentation

Forum discussions

  • Updating SEEG coordinates

Related tutorials

  • Epileptogenicity

  • ECoG/sEEG tutorial